This paper presents an analytical procedure to assess the monotonic (envelope) force-deformation response (capacity curve) of unbonded post-tensioning precast concrete (UPT) walls with internal and external replaceable dampers. This procedure, which can also be used to design UPT walls, was compared and validated against experimental evidence. A close agreement (strength discrepancies of 2% on average) was found between the response predictions and experimental results. This agreement was maintained until peak strength was achieved. Moreover, fiber-based models were implemented to further study the cyclic behavior of UPT walls designed according to the proposed analytical procedure. The numerical models were accurate in representing the global cyclic behavior of UPT walls in terms of strength, displacement capacity, and energy dissipation; nonetheless, these models showed some discrepancies in capturing the residual drifts of some UPT walls with internal dampers. A parametric analysis was also conducted to explore the influence of some design parameters on the deformation capacity and energy dissipation of UPT walls. It was found that the ratio of damper reinforcement is critical for the energy dissipation and self-centering capacity of UPT walls, so ratios of 0.10 to 0.25 should be provided to follow the limit states indicated in this paper. Based on the results, the analytical procedure and limit states presented in this paper are considered suitable for UPT walls with external replaceable dampers under total axial load ratios equal or lower than 0.125.
Finite element analysis was conducted on a R/C residential building with soft first story which was built in 1992 and heavily damaged in the 2016 Kumamoto Earthquake. Structural damage observed on first story column and second story beam members of the soft first story could be predicted in good accuracy. By carrying out a parametric study, it was found that the detail of second floor beam and wall above the soft first story affect to the horizontal load carrying capacity and deformation capacity of whole building.
29 February 2024 in Bulletin of the New Zealand Society for Earthquake Engineering
In this study, ultra-high-strength fiber-reinforced concrete (UFC) panels were used as a quick and effective measure for seismic strengthening of damaged reinforced concrete (RC) columns. Four 1/3-scale specimens, which replicated RC columns of the soft-first-story of a 10-story condominium building that was heavily damaged in the 2016 Kumamoto Earthquake, were constructed and tested. The specimens were strengthened using UFC panels after being preloaded to the drift ratio, at which the maximum load capacity of the target column was measured, and then subjected to the main loading until the ultimate state was reached. The UFC panels were installed on the two faces of the column in a direction parallel to the assumed loading direction. Two of the specimens had a UFC or RC wing wall attached to one side of the column, which was also aligned with the assumed loading direction. During the preloading and main loading, the specimens were subjected to a cyclic lateral load and varying axial load that simulated an earthquake load. The proposed method improved the maximum strength and ultimate drift ratio, and helped restore the initial stiffness of specimens with UFC panels and a wing wall to that of a column specimen during preloading. The test results of a previous study, wherein the target column, loading method, and strengthening method were the same but the specimens were not damaged before strengthening, were compared to study the impact of the damage on the RC column before strengthening.