1 July 2020 in Magazine of Concrete Research
Beam–column joints are generally recognised as critical regions in the analysis and design of moment-resisting reinforced-concrete (RC) frames subjected to both lateral and vertical loads. Such joints should be designed and detailed to ensure that they have adequate overstrength and allow adjacent beams to reach their full ductile capacities. To develop an improved method for predicting the deformation capacity of RC beam–column joint assemblies, the deformation contributions of structural members connecting the joint should be considered. A method is proposed to predict the deformation component ratios of RC beam–column joint assemblies that fail in shear after the adjacent beams have reached their full plastic capacities. The proposed method takes into account the effect of the longitudinal axial strain in the plastic hinge region of beams on the joint longitudinal strain and the strength deterioration of the joint. To verify the deformations of typical RC beam–column joint assemblies estimated using the proposed method, six specimens were tested. Furthermore, 35 experimental results of joints reported in the technical literature were compared with the deformations predicted by the proposed method. Comparisons between the observed and calculated deformations of the considered RC beam–column joint assemblies showed reasonable agreement.
1 October 2019 in Magazine of Concrete Research
Energy dissipation of columns in the post-yielding range of deformation plays a significant role in preventing the total collapse of reinforced-concrete (RC) structures. However, such plastic deformations cause elongation in plastic hinge regions of RC columns if the axial force ratio is low. This study investigated the elongation behaviour of RC columns by testing five groups of 20 specimens subjected to three different loading patterns. Experimental results showed that the longitudinal axial strain of RC columns was quite different from that of RC beams because of the presence of axial force. The longitudinal axial strain of RC columns reduced with increasing axial force. Axial strain was also a function of loading pattern and lateral reinforcement ratio. Based on these observations, an analytical model was developed to predict the axial strain behaviour of RC columns. The proposed model includes four path types: a loading region, an unloading region, a slip region and a repeated loading region. The model was verified against 32 test results, including specimens tested in this study and reported in the literature. The longitudinal axial strain predicted using the proposed model agreed reasonably well with the experimental axial strains results.