Prantik Saha

Prantik Saha

Auto-generated profile, based on publicly available information

Prantik Saha

University of California, Irvine

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2024 in ACS Energy Letters
Verified
Journal Article
Open access
DHDanielle A. Henckel
Danielle A. Henckel
PSPrantik Saha
Prantik Saha
SRSunil Rajana
Sunil Rajana
CBCarlos Baez-Cotto
Carlos Baez-Cotto
ATAudrey K. Taylor
Audrey K. Taylor
KNKenneth Neyerlin
Kenneth Neyerlin
Low-temperature electrochemical CO2 reduction has demonstrated high selectivity for CO when devices are operated with pure CO2 streams. However, there is currently a dearth of knowledge for systems operating below 30% CO2, a regime interesting for coupling electrochemical devices with CO2 point sources. Here we examine the influence of ionomer chemistry and cell operating conditions on the CO selectivity at low CO2 concentrations. Utilizing advanced electrochemical diagnostics, values for cathode catalyst layer ionic resistance and electrocatalyst capacitance as a function of relative humidity (RH) were extracted and correlated with selectivity and catalyst utilization. Staying above 20% CO2 concentration with at least a 50% cathode RH resulted in >95% CO/H2 selectivity regardless of the ionomer chemistry. At 10% CO2, however, >95% CO/H2 selectivity was only obtained at 95% RH under scenarios where the resulting electrode morphology enabled high catalyst utilization.

12 July 2018 in Faraday Discussions
Verified
Journal Article
Closed access
PDF file
WSWoochul Song
Woochul Song
YSYue-Xiao Shen
Yue-Xiao Shen
CLChao Lang
Chao Lang
PSPrantik Saha
Prantik Saha
IZIryna V. Zenyuk
Iryna V. Zenyuk
MKManish Kumar
Manish Kumar
In this paper, two unique selectivity trends of ML-PAP[5] membranes are discussed from the perspectives of channel geometry, ion exclusion, and linear molecule transport.

16 August 2023 in Advanced Sustainable Systems
Verified
Journal Article
Closed access
ABAlex Badgett
Alex Badgett
JBJoe Brauch
Joe Brauch
PSPrantik Saha
Prantik Saha
BPBryan Pivovar
Bryan Pivovar

1 April 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PSPrantik Saha
Prantik Saha
IZIryna V. Zenyuk
Iryna V. Zenyuk
We developed a method, by combining electrochemical and electrokinetic streaming current techniques to study ion distribution and ionic conductivity in the diffuse part of electrochemical double layer (EDL) of a metal-electrolyte interface, when potential is applied on the metal by a potentiostat. We applied this method to an electrochemically clean polycrystalline gold (poly Au)-electrolyte interface and measured zeta potential for various applied potentials, pH, and concentration of the electrolyte. Specific adsorption of chloride ions on poly Au was studied by comparing measurements of zeta potential in KCl and KClO4 electrolytes. In absence of specific adsorption, zeta potential was found to increase linearly with applied potential, having slope of 0.04–0.06. When Cl− adsorption occurs, zeta potential changes the sign from positive to negative value at ∼750 mV vs Ag/AgCl applied potential. Complementary cyclic voltammetry and X-ray photoelectron spectroscopy studies were conducted to determine a degree of chloride ion adsorption on a poly Au. A correlation was observed between the applied potential at which zeta potential is zero and potential of zero charge for poly Au. Ion-distribution and ionic conductivity in the diffuse layer were calculated from the measured zeta potential data using nonlinear Poisson-Boltzmann distribution.

1 January 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
PSPrantik Saha
Prantik Saha
DHDanielle Henckel
Danielle Henckel
CBCarlos Baez-Cotto
Carlos Baez-Cotto
FIFry Intia
Fry Intia
LHLeiming Hu
Leiming Hu
KNKenneth Neyerlin
Kenneth Neyerlin
Electrochemical CO2 reduction is a promising technology to capture and convert CO2 to valuable chemicals. High Faradaic efficiencies of CO2 reduction products are achieved with zero-gap alkaline CO2 electrolyzers with a supporting electrolyte at the anode (anolyte). Herein, we investigate the effect of anolyte on the electrode properties such as catalyst utilization, ionic accessibility etc. of a CO2 reduction cathode using electrochemical techniques and cell configurations that avoid the complexities related to co-electrolysis. Using 1M KOH as the anolyte and a Cu gas-diffusion-electrode with low Nafion content as the model CO2 reduction electrode, we find that electrode capacitance (proxy for electrochemically active surface area) and ionic conductivity inside the cathode increase approximately 4 and 447 times, respectively, in presence of KOH. Liquid anolyte wets the electrode’s pore structure more efficiently than capillary condensation of feed water vapor. The ionomer coverage is very low, and its distribution inside the electrode is highly fragmented. Surface ion conduction mechanisms inside the electrode are orders of magnitude lower than the bulk ion conduction in presence of anolyte. This study shows that when an anolyte (e.g., KOH) is used, catalyst utilization and ionic accessibility inside the electrode increase significantly.

30 May 2021 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
CLChristopher Pantayatiwong Liu
Christopher Pantayatiwong Liu
PSPrantik Saha
Prantik Saha
YHYing Huang
Ying Huang
PSPongsarun Satjaritanun
Pongsarun Satjaritanun
SSSirivatch Shimpalee
Sirivatch Shimpalee
IZIryna V. Zenyuk
Iryna V. Zenyuk
Gas diffusion layers (GDLs) are porous fiber layers that are used for various electrochemical applications, including fuel cells, electrolyzers, CO2 reduction reaction electrolyzers, and redox flow batteries. Depending on its application, a GDL’s wettability is controlled by the addition of polytetrafluoroethylene (PTFE). The PTFE addition is highly stochastic, resulting in inhomogeneous distribution. Furthermore, the fibers, carbonaceous binder, and PTFE all have different surface roughness and surface properties that dictate GDL wettability. To determine the contact angle of the GDL, goniometer measurements of external contact angle are used, where a droplet of water is placed on the top of the GDL and a contact angle is projected onto a detector. However, this form of measurement has limitations that need to be accounted for as the GDL is highly porous and its surface and internal contact angles might be different due to inhomogeneous binder and PTFE distribution. For the first time, we have applied a method to calculate the internal contact angle distribution of water inside various commercial GDLs. Lattice Boltzmann water transport simulations using these contact angle distributions yielded results much closer to experimental values than simulations that used goniometer-measured constant contact angles. XPS was used to correlate surface oxide groups to measured internal contact angles. AlRatrout et al. developed an open-source C++ code to compute local contact angles at triple phase boundary points (comprised of a solid and two fluids) from micro Xray computed tomography (XCT) images of porous media [1]. We applied it to segmented micro XCT images of water filled commercial GDL samples and computed local contact angles at air-GDL-water triple phase contacts points (Figure 1A). We obtained a state of mixed wettability inside all GDL samples, with contact angles ranging from 0° to 180° inside the pores (Figure 1B). Several works have calculated average contact angles similar to our results using other methods [2, 3]. Hydrophilicity is due to the presence of surface oxide groups on GDL fibers while hydrophobicity is due to the chemical nature of carbon and the roughness of the GDL fibers. Lattice Boltzmann water transport simulations were performed with the spatially distributed, mapped contact angles and constant contact angles measured with a goniometer (Figure 1C-F) [4]. When our mapped, mixed-wettability contact angle distributions were used, the simulation revealed several regions of high liquid saturation that the constant contact angle simulations did not capture. These results agreed with experimental observations. Thus, for robust water transport simulations, we suggest that distributed contact angles should be used instead of goniometer-measured constant contact angles. References: [1] AlRatrout, Ahmed, et al. "Automatic measurement of contact angle in pore-space images." Advances in water resources 109 (2017): 158-169. [2] Gunterman, Haluna Penelope Frances. Characterization of Fuel-Cell Diffusion Media. Diss. UC Berkeley, 2011. [3] Gostick, Jeffrey T., et al. "Capillary pressure and hydrophilic porosity in gas diffusion layers for polymer electrolyte fuel cells." Journal of power sources 156.2 (2006): 375-387. [4] Satjaritanun, Pongsarun, et al. "Numerical Predicting of Liquid Water Transport inside Gas Diffusion Layer for PEMFC Using Lattice Boltzmann Method." ECS Transactions 80.8 (2017): 187. Figure 1