2 December 2022 in IEEE Transactions on Instrumentation and Measurement
ferromagnetic structures, particularly the anti-eddy plate, in a bi-planar permanent-magnet-type low-field (0.05 T) magnetic resonance imaging (MRI) brain scanner can distort the gradient field in the target region. This study aims to provide a new gradient coil design method that reduces ferromagnetic influences on gradient field linearity. Thus, a simplified model of electromagnetic (EM) structures of the permanent-magnet-type MRI scanners was established. By using precise analytical proof, the anti-eddy plate was reduced to a homogeneous magnetic plate. The overall effects of the EM structures, which can be represented by bi-planar magnetic plates, were evaluated. In sequence, the image magnetic dipole was first introduced to show the effects of anti-eddy plates were added to the conventional equivalent magnetic dipole (EMD) approach. A novel equivalent image magnetic dipole (EIMD) method was proposed to build the gradient coil pattern. The effect of ferromagnetic materials was predicted throughout the gradient coil design phase using the proposed method, and a high-linear gradient field was generated under real working conditions. The computational and experimental results showed that the gradient coil was linear when ferromagnetic structures were present. The effectiveness of the proposed method was demonstrated by comparing T1-weighted images of the conventional method to those of the proposed method. The proposed method reduced image distortion caused by nearby EM structures in bi-planar permanent-magnet-type low-field MRI systems and provided an effective and concise solution for gradient coil designs.
1 September 2023 in IEEE Transactions on Instrumentation and Measurement
In an ultra-low-field magnetic resonance imaging (ULF-MRI) system, the uniformity of static magnetic field B 0 is essential for maintaining good imaging quality. However, achieving high B 0 homogeneity is difficult due to the low magnitude. This paper proposes a flexible active shimming approach for ULF B 0 optimization, where an original geometry-based method is presented for first- and second-order shim coil designs. Different types of shim coils are approximated by combinatorial geometric curves, where no additional wire is needed for overall connection. An optimization problem is established to ensure that each shim coil generates a high-purity harmonic magnetic field, which is comparable to the optimization results obtained using the conventional stream function method. A computer-controlled multichannel current source is designed to drive the second-order shim coils, where the current output reaches an accuracy of 1 mA. The performance of optimized coils is verified by imaging experiments. It is demonstrated that B 0 homogeneity is improved from 157 ppm to 111 ppm following the implementation of second-order shimming. The in vivo experiment shows that imaging quality is improved after shimming with the local signal-to-noise ratio increasing 1.16 to 1.92 folds.
1 January 2026 in IEEE Open Journal of Vehicular Technology