Carolina Dopico-González

Carolina Dopico-González

Auto-generated profile, based on publicly available information

Carolina Dopico-González

Bioengineering Research Group, School of Engineering Sciences, University of Southampton, Southampton, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Journal of Biomechanics
Verified
Journal Article
Closed access
CDCarolina Dopico-González
Carolina Dopico-González
ANAndrew M. New
Andrew M. New
MBMartin Browne
Martin Browne

13 February 2009 in Medical Engineering & Physics
Verified
Journal Article
Closed access
CDCarolina Dopico-González
Carolina Dopico-González
ANAndrew M. New
Andrew M. New
MBMartin Browne
Martin Browne
This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be taken into account in determining the performance of the construct. Monte Carlo sampling techniques were applied and the performance indicator was the maximum strain in the bone. The random input parameters were the joint load, the angle of the applied load and the material properties of the bone and the implant. Two Monte Carlo based simulations were applied, direct sampling and latin hypercube sampling. The results showed that the convergence of the mean value of the maximum strain improved gradually as a function of the number of simulations and it stabilised around a value of 0.008 after 6200 simulations. A similar trend was observed for the cumulative distribution function of the output. The strain output was most sensitive to the bone stiffness, followed very closely by the magnitude of the applied load. The application of latin hypercube sampling with 1000 simulations gave similar results to direct sampling with 10,000 simulations in a much reduced time. The results suggested that the number of simulations and the selection of parameters and models are important for the reliability of both the probability values and the sensitivity analyses.

1 June 2009 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
CDCarolina Dopico-González
Carolina Dopico-González
ANAndrew M. New
Andrew M. New
MBMartin Browne
Martin Browne
In the present study, a probabilistic finite element tool was implemented to assess an uncemented total hip replacement including variability in bone–implant version angle. The Monte Carlo method was used with two different performance indicators: the bone maximum nodal von-Mises elastic strain and the bone volume (BV) percentage exceeding specified strain limits. Implant version, bone stiffness and load magnitude were the most sensitive parameters. The results were more consistent using percentage BV under specified limit strains as the performance indicator, even for a low number of simulations. The reliability of the computational tool was demonstrated through a comparison with previous studies, and the consistency of the results for all strain limits investigated.