This study considers a rotary infrared-convective dryer with two stationary modules and hinged cradles. The task addressed relates to the insufficiently defined relationship between the source geometry, product movement, local radiant exposure, and product temperature. This work has calculated the influence of cradle geometry, gap, and shading on infrared flux distributions, while determining the effect of rotation speed on the temperature response of a melon slice. A computational model has been constructed in which infrared modules are represented by finite diffuse apertures, and the movement of the cradles determines the change in the local radiant flux over time. Transient heat and moisture transfer was calculated taking into account thermal conductivity, convective heat exchange, effective diffusive moisture, and evaporative cooling. With the base geometry, the average normalized flux was 0.12708, the width at half maximum was 112.93°, the energy equivalent width was 162.17°, and the exposure variation coefficient was 25.71%. Under the adopted opaque shading scenario, the average flux decreased by 17.0–19.2%. With a peak absorbed infrared load of 2.5 kW/m2, increasing the rotational speed from 0.5 to 10 min-1 over 1200 s reduced the maximum calculated temperature from 59.17 to 57.38°C. With the same average infrared flux, the cyclic load resulted in a maximum temperature 0.638–2.460°C higher than the constant intensity load. For a 150 mm gap and a peak load of 2.0 kW/m2, reaching the reference temperature of 60°C at frequencies of 2–5 min-1 was predicted to occur within 1861–1897 s. The calculated dependences allow for comparison of design and operating conditions; however, 60°C is not an established criterion for melon quality, so the model requires experimental verification