Michael Simon

Michael Simon

Auto-generated profile, based on publicly available information

Michael Simon

Fort Hare Institute of Technology, University of Fort Hare, Alice Campus, Alice 5700, Eastern Cape Province, South Africa

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
CMChristy Manyi-Loh
Christy Manyi-Loh
SMSampson N. Mamphweli
Sampson N. Mamphweli
Edson MeyerEdson Meyer
Edson Meyer
GMGolden Makaka
Golden Makaka
MSMichael Simon
Michael Simon
AOAnthony Okoh
Anthony Okoh
Cattle manure harbors microbial constituents that make it a potential source of pollution in the environment and infections in humans. Knowledge of, and microbial assessment of, manure is crucial in a bid to prevent public health and environmental hazards through the development of better management practices and policies that should govern manure handling. Physical, chemical and biological methods to reduce pathogen population in manure do exist, but are faced with challenges such as cost, odor pollution, green house gas emission, etc. Consequently, anaerobic digestion of animal manure is currently one of the most widely used treatment method that can help to salvage the above-mentioned adverse effects and in addition, produces biogas that can serve as an alternative/complementary source of energy. However, this method has to be monitored closely as it could be fraught with challenges during operation, caused by the inherent characteristics of the manure. In addition, to further reduce bacterial pathogens to a significant level, anaerobic digestion can be combined with other methods such as thermal, aerobic and physical methods. In this paper, we review the bacterial composition of cattle manure as well as methods engaged in the control of pathogenic microbes present in manure and recommendations that need to be respected and implemented in order to prevent microbial contamination of the environment, animals and humans.

CMChristy Manyi-Loh
Christy Manyi-Loh
SMSampson N. Mamphweli
Sampson N. Mamphweli
Edson MeyerEdson Meyer
Edson Meyer
AOAnthony Okoh
Anthony Okoh
GMGolden Makaka
Golden Makaka
MSMichael Simon
Michael Simon
With an ever increasing population rate; a vast array of biomass wastes rich in organic and inorganic nutrients as well as pathogenic microorganisms will result from the diversified human, industrial and agricultural activities. Anaerobic digestion is applauded as one of the best ways to properly handle and manage these wastes. Animal wastes have been recognized as suitable substrates for anaerobic digestion process, a natural biological process in which complex organic materials are broken down into simpler molecules in the absence of oxygen by the concerted activities of four sets of metabolically linked microorganisms. This process occurs in an airtight chamber (biodigester) via four stages represented by hydrolytic, acidogenic, acetogenic and methanogenic microorganisms. The microbial population and structure can be identified by the combined use of culture-based, microscopic and molecular techniques. Overall, the process is affected by bio-digester design, operational factors and manure characteristics. The purpose of anaerobic digestion is the production of a renewable energy source (biogas) and an odor free nutrient-rich fertilizer. Conversely, if animal wastes are accidentally found in the environment, it can cause a drastic chain of environmental and public health complications.

CMChristy Manyi-Loh
Christy Manyi-Loh
SMSampson N. Mamphweli
Sampson N. Mamphweli
Edson MeyerEdson Meyer
Edson Meyer
AOAnthony Okoh
Anthony Okoh
GMGolden Makaka
Golden Makaka
MSMichael Simon
Michael Simon
Anaerobic digestion of animal manure in biogas digesters has shown promise as a technology in reducing the microbial load to safe and recommended levels. We sought to treat dairy manure obtained from the Fort Hare Dairy Farm by investigating the survival rates of bacterial pathogens, through a total viable plate count method, before, during and after mesophilic anaerobic digestion. Different microbiological media were inoculated with different serial dilutions of manure samples that were withdrawn from the biogas digester at 3, 7 and 14 day intervals to determine the viable cells. Data obtained indicated that the pathogens of public health importance were 90%–99% reduced in the order: Campylobacter sp. (18 days) < Escherichia coli sp. (62 days) < Salmonella sp. (133 days) from a viable count of 10.1 × 103, 3.6 × 105, 7.4 × 103 to concentrations below the detection limit (DL = 102 cfu/g manure), respectively. This disparity in survival rates may be influenced by the inherent characteristics of these bacteria, available nutrients as well as the stages of the anaerobic digestion process. In addition, the highest p-value i.e., 0.957 for E. coli showed the statistical significance of its model and the strongest correlation between its reductions with days of digestion. In conclusion, the results demonstrated that the specific bacterial pathogens in manure can be considerably reduced through anaerobic digestion after 133 days.

28 December 2010 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Closed access
PDF file
MSMichael Simon
Michael Simon
Edson MeyerEdson Meyer
Edson Meyer

3 October 2016 in Journal of Engineering, Design and Technology
Verified
Journal Article
Closed access
STStephen Tangwe
Stephen Tangwe
MSMichael Simon
Michael Simon
Edson MeyerEdson Meyer
Edson Meyer
Purpose: This paper aims to show that by using air source heat pump (ASHP) water heater in the residential sector, the energy consumption from sanitary hot water production can be reduced by more than 50 per cent. Hence, this study quantitatively and qualitatively confirms that domestic ASHP water heater is a renewable and energy efficient device for sanitary hot water production. Design/methodology/approach: Design and building of a data acquisition system comprises a data logger, power meters, flow meters, temperature sensors, ambient and relative humidity sensor and an electronic input pulse adapter to monitor the ASHP water heater performance. All the sensors are accommodated by the U30-NRC data logger. The temperature sensors are installed on the inlet pipe containing a flow meter and the outlet pipe of the ASHP unit, the vicinity of both evaporator and expel cold air. An additional temperature sensor and a flow meter that cater for hot water drawn off measurements are incorporated into the data acquisition system (DAS). Findings: The result from a specific monitoring split type ASHP water heater gives an average daily coefficient of performance (COP) of 2.36 and the total electrical energy of 4.15 kWh, and volume of hot water drawn off was 273 L. These results were influenced by ambient temperature and relative humidity. Research limitations/implications: The cost involved in purchasing the entire sensors and data logger limits the number and categories of ASHP water heaters whose performance were going to be monitored. Pressure sensors were excluded in the data acquisition system. Practical implications: The data acquisition system can easily be designed and the logger can also be easily programed. Hence, no high technical or computer skills are needed to install the DAS and to be able to read out the results. Social implications: Hence, the data acquisition system can be installed on the entire domestic Eskom roll out air source heat pump water heaters to effectively determine the coefficient of performance and demand reductions. Originality/value: This DAS is the first of its kind to be built in South Africa to be used to determine the performance of an ASHP water heater with high accuracy and precision. DAS is also robust.

1 January 2015 in Journal of Clean Energy Technologies
Verified
Journal Article
Closed access
CMChristy Manyi-Loh
Christy Manyi-Loh
SMSampson N. Mamphweli
Sampson N. Mamphweli
Edson MeyerEdson Meyer
Edson Meyer
AOAnthony Okoh
Anthony Okoh
GMGolden Makaka
Golden Makaka
MSMichael Simon
Michael Simon