G. Damian Brusko

G. Damian Brusko

Auto-generated profile, based on publicly available information

G. Damian Brusko

Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, Florida, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Neurosurgery Clinics of North America
Verified
Journal Article
Closed access
GBG. Damian Brusko
G. Damian Brusko
MWMichael Y. Wang
Michael Y. Wang

1 April 2018 in World Neurosurgery
Verified
Journal Article
Closed access
DEDaniel G. Eichberg
Daniel G. Eichberg
SBSimon Buttrick
Simon Buttrick
GBG. Damian Brusko
G. Damian Brusko
Michael E. IvanMichael E. Ivan
Michael E. Ivan
RSRobert M. Starke
Robert M. Starke
RKRicardo J. Komotar
Ricardo J. Komotar

1 September 2019 in Annals of Translational Medicine
Verified
Journal Article
Open access
JKJohn Paul G. Kolcun
John Paul G. Kolcun
GBG. Damian Brusko
G. Damian Brusko
MWMichael Y. Wang
Michael Y. Wang
Innovations in surgical techniques and technologies have enabled spine surgeons to offer patients less morbid alternatives to traditional spine procedures. This review will explore the development of the endoscopic transforaminal lumbar interbody fusion (TLIF) without general endotracheal anesthesia (GETA) and discuss the technical refinements and innovations learned from experiences with this technique. The Awake TLIF employs several key technological innovations: (I) conscious sedation; (II) endoscopic visualization; (III) an expandable interbody device; (IV) recombinant human bone morphogenetic protein; (V) long-acting local analgesia; and (VI) percutaneous instrumentation. Technical refinements, including premedication for prophylaxis against nausea, vomiting, and epistaxis, were made as a result of early experiences with this technique. Results from the first 100 patients to undergo the Awake TLIF demonstrated durable clinical benefit beyond one year postoperatively. Operating time, blood loss, and hospital length of stay averages well below those generally seen with conventional MIS TLIF. Patients achieved a significant reduction in Oswestry Disability Index from baseline of -12.3 points (P<0.0001). In this initial 100 patient cohort, four conversions to GETA were required and four complications resulted, three of which occurred during the first 50 cases. To date, over 200 Awake TLIF cases and the first three-level procedure have been performed. Endoscopic TLIF without the use of general anesthesia is a novel but promising approach for short-segment lumbar fusion. Continued technical innovations will likely afford greater improvements in outcomes, both in the acute and long-term recovery periods.

1 May 2020 in World Neurosurgery
Verified
Journal Article
Closed access
RPRoberto J. Perez-Roman
Roberto J. Perez-Roman
GBG. Damian Brusko
G. Damian Brusko
SBS. Shelby Burks
S. Shelby Burks
ASAldo N. Serafini
Aldo N. Serafini
MWMichael Y. Wang
Michael Y. Wang

1 December 2019 in World Neurosurgery
Verified
Journal Article
Closed access
AFAndrew A. Fanous
Andrew A. Fanous
JKJohn Paul G. Kolcun
John Paul G. Kolcun
GBG. Damian Brusko
G. Damian Brusko
MPMichael Paci
Michael Paci
GGGeorge M. Ghobrial
George M. Ghobrial
JGJoseph P. Gjolaj
Joseph P. Gjolaj

19 March 2020 in Cureus
Verified
Journal Article
Open access
PDF file
GBGregory Basil
Gregory Basil
GBG Damian Brusko
G Damian Brusko
JBJordan Brooks
Jordan Brooks
Michael Y WangMichael Y Wang
Michael Y Wang
Introduction: The learning curve associated with endoscopic approaches to the spine is well established. In this study, we present our endoscopic training methodology and discuss the concepts and rationale of laboratory training as it relates to improving comfort and skill with endoscopic techniques. Materials and Methods: A three-part endoscopic training laboratory for neurosurgical trainees and attendings was organized at the University of Miami, which included a lecture, instrumentation demonstration, and both synthetic model and cadaveric practice sessions. Participants completed pre- and post-lab surveys gauging their comfort and competency in the transforaminal approach to the lumbar spine. Results: There were a total of 22 participants, with eight completing the pre-lab survey and 10 completing the post-lab survey. Sixteen participants engaged in the lab practical, with six of these participants performing the transforaminal approach on both the model and the cadaver. An increase in comfort level was demonstrated on the post-lab survey (5.9/10) for the transforaminal approach as compared to the pre-lab survey (2.6/10). Additionally, participants found the training model to be an effective teaching aid for the transforaminal technique (8.8/10). Conclusions: We believe that our study demonstrates the utility of simulated model-based training for gaining comfort and proficiency with endoscopic approaches to the spine and introduces a safe, cost-effective method of educating practitioners on novel endoscopic approaches.