Fatemeh Hafez Maleki

Fatemeh Hafez Maleki

Auto-generated profile, based on publicly available information

Fatemeh Hafez Maleki

Dental Implant Research Center, Department of Oral and Maxillofacial Radiology, School of Dentistry, Hamadan University of Medical Sciences, Iran

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2019 in Dental and Medical Problems
Verified
Journal Article
Open access
ASAbbas Shokri
Abbas Shokri
HZHossein Hosseini Zarch
Hossein Hosseini Zarch
FHFatemeh Hafezmaleki
Fatemeh Hafezmaleki
RKRonak Khamechi
Ronak Khamechi
PAPayam Amini
Payam Amini
LRLeila Ramezani
Leila Ramezani
Temporomandibular disorders (TMD) are the most common reason of non-dental pain in the orofacial region. A clinical examination of the temporomandibular joint (TMJ) with additional imaging is the most recommended procedure for TMD diagnosis. The objective of this study was to evaluate the association between TMD and the condylar position in the glenoid fossa by examining a group of patients suffering from TMD compared with a control group of patients without TMD. In this study, we used cone-beam computed tomography (CBCT) images for measurements. Sixty-five symptomatic joints were selected from 48 patients with TMD. Sixtyfive joints were selected from a total of 96 asymptomatic joints in the control group. The superior, anterior and posterior area of the joint, and the steepness of the articular eminence were measured on the CBCT images. The data was analyzed using Pearson's χ2 test. The position of the condyle was significantly more posterior in the joints with TMD, and more anterior and centric in the asymptomatic joints. Statistically, the vertical position of the condyle and the steepness of the articular eminence had no significant relation with the occurrence of TMD. In this study, we observed that the posterior condylar position is more common in TMD patients, but it is not the reason for diagnosing TMD, and the reason of the posterior position of the condyle should be investigated before any decisions pertaining to treatment are made. In future, studies should focus on evaluating how the position of the condyle will change after the treatment of patients with TMD.

1 May 2016 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
FSFatemeh Salemi
Fatemeh Salemi
ASAbbas Shokri
Abbas Shokri
FMFatemeh Hafez Maleki
Fatemeh Hafez Maleki
MFMaryam Farhadian
Maryam Farhadian
GDGholamreza Dashti
Gholamreza Dashti
HRHadi Ranjzad
Hadi Ranjzad
In maxillofacial imaging, cone beam computed tomography (CBCT) is currently the modality of choice for assessment of bony structures of the temporomandibular joint (TMJ). Factors affecting the quality of CBCT images can change its diagnostic accuracy. This study aimed to assess the effect of field of view (FOV) and defect size on the accuracy of CBCT scans for detection of bone defects of the TMJs. This study was conducted on 12 sound TMJs of 6 human dry skulls. Erosions and osteophytes were artificially induced in 0.5, 1, and 1.5-mm sizes on the anterior-superior part of the condyle; CBCT scans were obtained with 6, 9, and 12-inch FOVs by NewTom 3G CBCT system. Two maxillofacial radiologists evaluated the presence/absence and type of defects on CBCT scans. The Cohen kappa was calculated to assess intra- and interobserver reliability. The Mann–Whitney U test was applied to compare the diagnostic accuracy of different FOVs. In comparison of 6- and 12-inch, 9- and 12-inch FOVs in detection of different sizes of erosive lesions, difference was significant (P <0.05), whereas difference between 6- and 9 inch just in 0.5-mm erosive lesion was significant (P = 0.04). In comparison of 6- and 12-inch FOVs in detection of different sizes of osteophyte lesion, difference was significant (P < 0.05), whereas between 6- and 9-inch FOVs statistically significant difference was not observed (P > 0.05). The highest and the lowest diagnostic accuracy of CBCT scans for condyle defects were obtained with 6-inch and 12-inch FOVs, respectively. Diagnostic accuracy of CBCT scans increased with an increase in size of bone defects.