10 March 2021 in IEEE Transactions on Industrial Electronics
This article presents a method to reduce the torque ripple in an 8/6 four-phase switched reluctance motor (SRM). The proposed scheme introduces a nonlinear modulating factor dependent on the rotor position and magnitude of the phase currents. This factor manipulates the currents in two adjacent phases during commutation and reduces the torque ripple effectively. Unlike the conventionally available torque-sharing functions, the proposed method instantaneously modulates every phase current obtained mathematically based on the other phase current in order to maintain the net torque constant. The proposed method requires minimal offline analysis and offers maximum possible torque with a minimal ripple. The method is simple and easy to implement due to a low computational burden. The proposed algorithm is implemented using MATLAB/Simulink software and is also validated experimentally on a 0.6-hp 8/6 SRM using a field-programmable-gate-arrays-based hardware setup developed in the laboratory. Typical results are presented and compared with the existing techniques. A torque ripple of $\approx 8\%$ has been achieved.
21 March 2022 in IEEE Transactions on Transportation Electrification
In this article, a modular fault-tolerant power converter for 8/6 four-phase switched reluctance motor (SRM) drives is presented. The proposed converter can work for both open-circuit (OC) and short-circuit (SC) fault conditions in the power semiconductor switches. A semiconductor switch module and a relay circuit are used for achieving the fault tolerance feature. The proposed converter is modular and provides independent fault-tolerant control for all phases. It also uses a minimum number of switches when compared with other fault-tolerant converter topologies. The proposed converter is tested for a fault in single as well as multiple phases using MATLAB/Simulink software and is validated experimentally on a 0.6 hp 8/6 SRM using an FPGA-based hardware setup developed in the laboratory. Detailed results are presented and compared with existing fault-tolerant converter topologies. A fault repair time of 2 ms has been achieved for both open and SC faults.
21 February 2018 in IEEE Transactions on Energy Conversion
This paper presents a unified approach to deal with sliding mode controllers used for induction motor drives. The study digs deep to identify matched and unmatched disturbances and derive conditions to satisfactorily reject the same. The investigation reveals fundamental limitations of hysteresis (first order sliding mode) controllers those can be overcome by higher order controllers. Second order sliding mode controllers are investigated to achieve disturbance rejection and chattering free performance. It is shown that the drive with second order sliding mode controllers maintains constant switching frequency and decoupling between torque and flux simultaneously in the face of sudden speed, load, or parameter variations. Also, it is shown that the dynamic performance can be drastically improved at higher sampling frequencies keeping the switching frequency constant. Extensive simulations are carried out in Matlab/Simulink. Implementation of such a drive becomes feasible with low cost FPGAs due to their inherent parallel processing capability. A vector controlled induction motor drive is developed and the controller is implemented using FPGA to corroborate the simulation results through experimentations.
6 April 2022 in IEEE Transactions on Instrumentation and Measurement
Grid-connected converters require grid frequency and phase information for controlling the power injections into the grid. This information is achieved by a phase-locked loop (PLL) or frequency-locked loop (FLL) algorithms. The accuracy, reliability, and ease of implementation of the PLL/FLL algorithms in all grid conditions dictate the performance of the grid-connected converters. This article proposes a digital FLL for single-phase grid-connected systems. The proposed FLL tracks the frequency accurately, even in heavily distorted grid conditions. It uses a second-order generalized integrator (SOGI) as a pre-filter and a digital counter, based on the zero-crossing detection (ZCD) logic for estimating the grid frequency and phase angle. It does not require complex filters and tuning of multiple parameters. The implementation of the proposed FLL is simple and has less computational overhead. The ability of the proposed FLL to track the frequency and phase under various steady-state (dc-offset and harmonics) and transient (voltage sag, frequency drift, and phase jump) grid disturbances is tested in simulation using MATLAB/SIMULINK, and the results are reported. The experimental validation is done using a field programmable gate array (FPGA) controller in the laboratory. The proposed algorithm is able to track the estimates within 1.2 cycles of the grid voltage when tested under a heavy-distorted grid having 26.4% total harmonic distortion (THD). The measurement uncertainties and results of single-phase grid-connected inverter (GCI) using the proposed FLL are also presented.
6 June 2024 in IEEE Transactions on Industrial Electronics
This article proposes a novel selective harmonic mitigation technique based on higher order sliding-mode control. The method aims to reduce total harmonic distortion (THD) while mitigating multiple harmonics as necessary according to existing standards, such as IEEE 519-2022. Unlike selective harmonic elimination (SHE), which can only eliminate a fixed number of harmonics, the proposed method can accommodate $\boldsymbol{(m-1)}$ or more harmonics corresponding to $\boldsymbol {m}$ switching angles per quarter wave. The proposed methodology constrains the number of switching angles similar to SHE but achieves a lower THD and meets the IEEE 519-2022 requirements by alleviating multiple harmonics simultaneously. Complete details of the proposed algorithm are provided for a general case with $\boldsymbol {m}$ switching angles. Simulations in MATLAB/Simulink and experiments on a field-programmable gate array (FPGA) prototype validate the technique for $\boldsymbol{m=5}$ switching angles. Various test cases demonstrate the ability to mitigate specific harmonics while minimizing THD. Notably, the proposed SHM technique could mitigate up to four additional lower order harmonics above SHE with just five switching angles and two levels.
10 February 2022 in IEEE Transactions on Power Electronics
This article proposes a converter topology that can provide fast discharging for any N-phase switched reluctance motor (SRM) drive. The proposed converter achieves fast discharging with only (N+1) switches for an N-phase SRM drive. The discharging can also be varied and made faster as per requirement. The proposed converter achieves fast discharging by dumping the winding energy to a capacitor and feeding it back to the source through a flyback transformer. The proposed converter uses fewer switches, is easy to control, and has variable discharging voltage which can be made much greater than the supply voltage. The proposed converter has been implemented with a four-phase SRM drive using MATLAB/Simulink software and the results are presented. A hardware prototype of the proposed converter is developed in the laboratory and tested on a four-phase SRM. The corresponding experimental results are presented at different operating conditions. The proposed converter is also compared with other existing SRM converters with respect to different performance metrics and a detailed comparison table is presented. Using the proposed converter, a minimum discharge time of 0.32 ms has been achieved at 3 A reference current.