Davide Ninarello

Davide Ninarello

Auto-generated profile, based on publicly available information

Davide Ninarello

Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano Milan Italy

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2023 in Metals
Verified
Journal Article
Open access
PDF file
ANAdelaide Nespoli
Adelaide Nespoli
DNDavide Ninarello
Davide Ninarello
CFCarlo Fanciulli
Carlo Fanciulli
Shape memory alloys (SMA) are functional materials known for their shape memory and pseudoelastic properties, which originated from a thermoelastic phase transition between two solid phases: austenite and martensite. The ranges of temperature at which austenite and martensite are stable depend primarily on the chemical composition and the thermomechanical history of the alloy. This work presents a broad overview of shape memory alloys presenting the thermoelastic phase transition at cryogenic temperatures—that is, at temperatures below the freezing point of water. Currently, this class of SMA is not very well explored due to the difficulties in conducting both structural and functional experimentations at very low temperatures. However, these materials are of great importance for extreme environments such as space. In this work, the different classes of cryogenic SMA will first be presented as a function of their phase transformation temperatures. Hints of their mechanical performance will also be reported. Cu-based systems have been identified as cryogenic SMA presenting the lowest phase transformation temperatures. The lowest measured Ms (45 K) was found for the Cu-8.8Al-13.1Mn (wt.%) alloy.

28 August 2023 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Open access
PDF file
DNDavide Ninarello
Davide Ninarello
FPFrancesca Passaretti
Francesca Passaretti
ANAdelaide Nespoli
Adelaide Nespoli
The design process of devices based on shape memory alloys (SMA) is particularly demanding. It is fundamental the investigation of parameters describing the thermo-mechanical behavior of these materials, such as the phase transformation temperatures and the Clausius-Clapeyron coefficient (CCC). The aim of this study is to determine how heat treatment (HT) affects the above-mentioned parameters on two commercially available body-temperature NiTi alloys. This analysis is accomplished through differential scanning calorimetry (DSC) and strain recovery (SR) tests. Finally, the two NiTi alloys have been compared to determine whether exists a significant difference between different casting batches of the same commercial alloy conformed to the ASTM F2063. It results that both alloys present a similar overall trend of Af as a function of HT temperature and time, even if the values significantly differ for treatment at temperatures higher than 773 K for all HT times. Furthermore, it is noted that the HT time presents a minor effect on the value of Af. After the SR analysis, it has been possible to highlight the effect of the HT on the values of CCC for As, Ms and Rs. The overall trend is similar between the two NiTi alloys. These results lead to the conclusion that HT highly affect not only the transformation temperatures but also the transformation path of the alloy, thus its mechanical properties.

18 October 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
DNDavide Ninarello
Davide Ninarello
ABAlberto Ballardini
Alberto Ballardini
GMGiacomo Morozzi
Giacomo Morozzi
LBLuigi La Barbera
Luigi La Barbera
Treatment of critical-sized bone defects typically involves implantation of a bone graft. Various types of bone grafts are nowadays marketed, categorized by their origin as allografts, xenografts, or synthetic grafts. Despite their widespread use, a comprehensive understanding of their morphology and mechanical response remains elusive. Controlling these characteristics for promoting bone growth and ensuring mechanical resistance remains challenging, especially in load-bearing districts. This study aims to systematically review existing literature to delineate the principal morpho-mechanical characteristics of marketed bone grafts designed for load-bearing applications. Furthermore, the obtained data are organized and deeply discussed to find out the relationship between different graft characteristics. Among 196 documents identified through PRISMA guidelines, encompassing scientific papers and 510(k) documents, it was observed that a majority of marketed bone grafts exhibited porosity akin to bone (>60%) and mechanical properties resembling those of low-bone volume fraction trabecular bone. The present review underscores the dearth of information regarding the morpho-mechanical characteristics of bone grafts and the incomparability of data derived from different studies, due to the absence of suitable standards and guidelines. The need for new standards and complete and transparent morpho-mechanical characterization of marketed bone grafts is finally emphasized. Such an approach would enhance the comparability of data, aiding surgeons in selecting the optimal device to meet patient's needs.

11 March 2024 in Metals
Verified
Journal Article
Open access
PDF file
ANAdelaide Nespoli
Adelaide Nespoli
FPFrancesca Passaretti
Francesca Passaretti
DNDavide Ninarello
Davide Ninarello
MPMarcella Pani
Marcella Pani
Cristina ArtiniCristina Artini
Cristina Artini
CFCarlo Fanciulli
Carlo Fanciulli
In extreme temperature environments, a newly emerging engineering application involves both the active and passive control of structures using cryogenic shape memory alloys, which are smart materials able to recover high deformation below the freezing point. With the objective of carrying out new advances in this area, the present work aims to investigate the Cu-7.5Al-13.5Mn (wt.%) shape memory alloy. Thermal, microstructural, and thermomechanical analyses of as-cast and hot-rolled specimens were performed, taking into account the effects of annealing and solubilization. It was observed that the phase transition occurs at temperatures below 120 K and changes according to the thermo-mechanical path. Specifically, hot-rolling lowers the phase transition temperature range with respect to the as-cast condition–from 34 K to 23 K for Mf, and from 89 K to 80 K for Af. Additionally, when the annealing temperature rises, the phase transformation temperature increases as well, and the alloy loses its cryogenic features when heat treated above 473 K. Finally, loss factors of 0.06 and 0.088, which were respectively found in dynamic and static settings, validate the material’s good damping response.

17 August 2023 in Bio-Design and Manufacturing
Verified
Journal Article
Open access
PDF file
ANAdelaide Nespoli
Adelaide Nespoli
DNDavide Ninarello
Davide Ninarello
EBEnrico Bassani
Enrico Bassani
VDVilliam Dallolio
Villiam Dallolio
Among surgical procedures, suturing is considered simple. However, in some situations, suturing is not easy or feasible. Here, we present proof of concept of a new self-tightening needle-less suture made of a NiTi alloy. The new device is designed to overcome two demanding steps of traditional suturing: needle introduction and manual knotting. Our novel suture is composed only of a short NiTi wire that is able to change shape by exploiting a thermoelastic phase transition. This shape change is achieved by increasing the temperature from that of the operating room (e.g., 20–22 °C) to 32 °C using warm water. Suturing consists of two steps: suture introduction, in which the suture is in an open configuration, and shape recovery (i.e., closed configuration). The closed configuration is maintained at human body temperature thanks to peculiar pseudoelastic properties of the NiTi material. Finally, thermal and functional characterization verified the simplicity and effectiveness of the proposed device. Graphic abstract

1 September 2026 in JOR SPINE
Verified
Journal Article
Open access
DNDavide Ninarello
Davide Ninarello
LBLuigi La Barbera
Luigi La Barbera
Background: The treatment of severe disc pathologies through lumbar interbody fusion (LIF) involves the insertion of an interbody cage into the degenerated disc space, together with a supporting fixation system. Conventional cage materials, such as Ti6Al4V and PEEK, present several limitations, most notably their non‐biodegradability, increasing the risk of cage migration and long‐term subsidence (up to 40% incidence). Bioceramics may represent an option while addressing the issue of biodegradability. This study preliminarily investigates the applicability of a commercial bioceramic as an interbody cage material for LIF. Methods: First, an intact L4‐L5 functional spine unit (FSU) was validated under both pure moments and combined loading conditions. Subsequently, all surgical steps of the LIF procedure were simulated, followed by postoperative physiological loading to compare the mechanical performance of the ceramic device with standard titanium cages. Two surgical techniques, posterior‐LIF (PLIF) and eXtreme‐LIF (XLIF), were analyzed. Each simulation assessed the mechanical strength of the interbody cage, the posterior fixation, and the vertebral bone, together with the FSU kinematic. Results: The intact model accurately predicted literature‐reported kinematics and intradiscal pressure, and the LIF model reproduced forces on titanium cages consistent with in vitro measurements on human specimens. Both XLIF and PLIF procedures resulted in significant kinematic stabilization of the FSU, with > 70% reduction in range of motion. For PLIF, ceramic cages sustained applied loads with no predicted failure, while XLIF showed minimal interface failure (< 0.6%). Compared with titanium, ceramic cages significantly reduced adjacent vertebral strain, lowering the subsidence risk, without overloading the posterior fixation system. Conclusion: The present study supports the potential of bioceramics as viable materials for interbody cage applications in LIF procedures. Experimental tests and clinical validation should be accompanied to further cage design optimization to enhance the safety margins of this novel bioceramic device and ensure proper clinical effectiveness.