Shaoyan Pan

Shaoyan Pan

Auto-generated profile, based on publicly available information

Shaoyan Pan

Department of Biomedical Informatics and the Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2025 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SPShaoyan Pan
Shaoyan Pan
JPJunbo Peng
Junbo Peng
YGYuan Gao
Yuan Gao
SLShao-Yuan Lo
Shao-Yuan Lo
TLTianyu Luan
Tianyu Luan
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang
In the sphere of Cone Beam Computed Tomography (CBCT), acquiring X-ray projections from sufficient angles is indispensable for traditional image reconstruction methods to accurately reconstruct 3D anatomical intricacies. However, this acquisition procedure for the linear accelerator-mounted CBCT systems in radiotherapy takes approximately one minute, impeding its use for ultra-fast intra-fractional motion monitoring during treatment delivery. To address this challenge, we introduce the Patient-specific Cycle-domain Geometric-integrated Denoising Diffusion Probabilistic Model (CG-DDPM). This model aims to leverage patient-specific priors from patient’s CT/4DCT images, which are acquired for treatment planning purposes, to reconstruct 3D CBCT from a single-view 2D CBCT projection of any arbitrary angle during treatment, namely single-view reconstructed CBCT (svCBCT). The CG-DDPM framework encompasses a dual DDPM structure: the Projection-DDPM for synthesizing comprehensive full-view projections and the CBCT-DDPM for creating CBCT images. A key innovation is our Cycle-Domain Geometry-Integrated (CDGI) method, incorporating a Cone Beam X-ray Geometric Transformation Module (GTM) to ensure precise, synergistic operation between the dual DDPMs, thereby enhancing reconstruction accuracy and reducing artifacts. Evaluated in a study involving 37 lung cancer patients, the method demonstrated its ability to reconstruct CBCT not only from simulated X-ray projections but also from real-world data. The CG-DDPM significantly outperforms existing V-shape convolutional neural networks (V-nets), Generative Adversarial Networks (GANs), and DDPM methods in terms of reconstruction fidelity and artifact minimization. This was confirmed through extensive voxel-level, structural, visual, and clinical assessments. The capability of CG-DDPM to generate high-quality reconstructed CBCT from a single-view projection at any arbitrary angle using a single model opens the door for ultra-fast, in-treatment volumetric imaging. This is especially beneficial for radiotherapy at motion-associated cancer sites and image-guided interventional procedures.

18 October 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
DVDavid Viar-Hernandez
David Viar-Hernandez
JMJuan Manuel Molina-Maza
Juan Manuel Molina-Maza
SPShaoyan Pan
Shaoyan Pan
ESElahheh Salari
Elahheh Salari
CCChih-Wei Chang
Chih-Wei Chang
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang
Background. Adaptive radiotherapy (ART) requires precise tissue characterization to optimize treatment plans and enhance the efficacy of radiation delivery while minimizing exposure to organs at risk. Traditional imaging techniques such as cone beam computed tomography (CBCT) used in ART settings often lack the resolution and detail necessary for accurate dosimetry, especially in proton therapy. Purpose. This study aims to enhance ART by introducing an innovative approach that synthesizes dual-energy computed tomography (DECT) images from CBCT scans using a novel 3D conditional denoising diffusion probabilistic model (DDPM) multi-decoder. This method seeks to improve dose calculations in ART planning, enhancing tissue characterization. Methods. We utilized a paired CBCT-DECT dataset from 54 head and neck cancer patients to train and validate our DDPM model. The model employs a multi-decoder Swin-UNET architecture that synthesizes high-resolution DECT images by progressively reducing noise and artifacts in CBCT scans through a controlled diffusion process. Results. The proposed method demonstrated superior performance in synthesizing DECT images (High DECT MAE 39.582 ± 0.855 and Low DECT MAE 48.540± 1.833) with significantly enhanced signal-to-noise ratio and reduced artifacts compared to traditional GAN-based methods. It showed marked improvements in tissue characterization and anatomical structure similarity, critical for precise proton and radiation therapy planning. Conclusions. This research has opened a new avenue in CBCT-CT synthesis for ART/APT by generating DECT images using an enhanced DDPM approach. The demonstrated similarity between the synthesized DECT images and ground truth images suggests that these synthetic volumes can be used for accurate dose calculations, leading to better adaptation in treatment planning.

26 November 2024
Verified
Book Chapter
Closed access
PDF file
YLYuheng Li
Yuheng Li
TLTianyu Luan
Tianyu Luan
YWYizhou Wu
Yizhou Wu
SPShaoyan Pan
Shaoyan Pan
YCYenho Chen
Yenho Chen
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang

23 November 2023 in Frontiers in Oncology
Verified
Journal Article
Open access
YGYuan Gao
Yuan Gao
CCChih-Wei Chang
Chih-Wei Chang
JRJustin Roper
Justin Roper
MAMarian Axente
Marian Axente
YLYang Lei
Yang Lei
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang
Background: The number of patients undergoing proton therapy has increased in recent years. Current treatment planning systems (TPS) calculate dose maps using three-dimensional (3D) maps of relative stopping power (RSP) and mass density. The patient-specific maps of RSP and mass density were obtained by translating the CT number (HU) acquired using single-energy computed tomography (SECT) with appropriate conversions and coefficients. The proton dose calculation uncertainty of this approach is 2.5%-3.5% plus 1 mm margin. SECT is the major clinical modality for proton therapy treatment planning. It would be intriguing to enhance proton dose calculation accuracy using a deep learning (DL) approach centered on SECT.Objectives: The purpose of this work is to develop a deep learning method to generate mass density and relative stopping power (RSP) maps based on clinical single-energy CT (SECT) data for proton dose calculation in proton therapy treatment.Methods: Artificial neural networks (ANN), fully convolutional neural networks (FCNN), and residual neural networks (ResNet) were used to learn the correlation between voxel-specific mass density, RSP, and SECT CT number (HU). A stoichiometric calibration method based on SECT data and an empirical model based on dual-energy CT (DECT) images were chosen as reference models to evaluate the performance of deep learning neural networks. SECT images of a CIRS 062M electron density phantom were used as the training dataset for deep learning models. CIRS anthropomorphic M701 and M702 phantoms were used to test the performance of deep learning models.Results: For M701, the mean absolute percentage errors (MAPE) of the mass density map by FCNN are 0.39%, 0.92%, 0.68%, 0.92%, and 1.57% on the brain, spinal cord, soft tissue, bone, and lung, respectively, whereas with the SECT stoichiometric method, they are 0.99%, 2.34%, 1.87%, 2.90%, and 12.96%. For RSP maps, the MAPE of FCNN on M701 are 0.85%, 2.32%, 0.75%, 1.22%, and 1.25%, whereas with the SECT reference model, they are 0.95%, 2.61%, 2.08%, 7.74%, and 8.62%. Conclusion: The results show that deep learning neural networks have the potential to generate accurate voxel-specific material property information, which can be used to improve the accuracy of proton dose calculation.Advances in knowledge: Deep learning-based frameworks are proposed to estimate material mass density and RSP from SECT with improved accuracy compared with conventional methods.