Vascular endothelial growth factor (VEGF) produced by tumor cells plays a central role in stimulating angiogenesis required for solid tumor growth. VEGF-specific antibodies inhibit tumor cell line growth in animal models and a humanized monoclonal anti-VEGF antibody (bevacizumab [Avastin]) is approved as a treatment for metastatic cancer. We hypothesized that administration of an adenoviral (Ad) vector expressing the murine monoclonal antibody equivalent of bevacizumab would suppress human tumor growth in vivo. The Ad vector (AdαVEGF) encodes the light chain and heavy chain cDNAs of monoclonal antibody A.4.6.1, a murine antibody that specifically recognizes human VEGF with the same antigen-binding site as bevacizumab. AdαVEGF efficacy in vivo was evaluated with A-673 rhabdomyosarcoma and DU 145 prostate carcinoma cells in human tumor cell xenografts in SCID mice. For both tumor models, AdαVEGF directed the expression of high anti-human VEGF IgG antibody titers in vivo, the numbers of mitotic nuclei and blood vessels in the tumor were significantly decreased (p < 0.05), tumor growth was suppressed (p < 0.05), and there was increased survival (p < 0.005). Thus, AdαVEGF, encoding a murine monoclonal antibody that is the equivalent of bevacizumab, effectively suppresses the growth of human tumors, suggesting gene therapy as an alternative to bevacizumab monoclonal antibody therapy.
In this study, we investigated the process of preconcentrate and determine trace amounts of Auramine O (AO) and methylene blue (MB) dyes in environmental water samples. For this purpose, the ultrasound-assisted dispersive-magnetic nanocomposites-solid-phase microextraction (UA-DMNSPME) method was performed to extract AO and MB from aqueous samples by applying magnesium oxide nanoparticles (MgO-NPs). The proposed technique is low-cost, facile, fast, and compatible with many existing instrumental methods. Parameters affecting the extraction of AO and MB were optimized using response surface methodology (RSM). Short extraction time, low experimental tests, low consumption of organic solvent, low limits of detection (LOD), and high preconcentration factor (PF) was the advantages of method. The PF was 44.5, and LOD for AO and MB was 0.33 ng mL−1 and 1.66 ng mL−1, respectively. The linear range of this method for AO and MB were 1–1000 ng mL−1 and 5–2000 ng mL−1, respectively. In addition, the relative standard deviation (RSD; n = 5) of the mentioned analytes was between 2.9% and 3.1%. The adsorption–desorption studies showed that the efficiency of adsorbent extraction had not declined significantly up to 6 recycling runs, and the adsorbent could be used several times. The interference studies revealed that the presence of different ions did not interfere substantially with the extraction and determination of AO and MB. Therefore, UA-DMNSPME-UV/Vis method can be proposed as an efficient method for preconcentration and extraction of AO and MB from water and wastewater samples.