K. O. Timofeeva

K. O. Timofeeva

Auto-generated profile, based on publicly available information

K. O. Timofeeva

St. Petersburg State University Hospital

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2023 in Pirogov Russian Journal of Surgery
Verified
Journal Article
Closed access
ABA.M. Belousov
A.M. Belousov
VAV.P. Armashov
V.P. Armashov
DSD.D. Shkarupa
D.D. Shkarupa
TAT.YU. Anushchenko
T.YU. Anushchenko
TFT.S. Filipenko
T.S. Filipenko
NMN.L. Matveev
N.L. Matveev
Objective. The objective of the study was to analyze histological changes in the site of the meshes FTOREX, FTOREX coated with carboxymethylcellulose, Ventralight ST, Symbotex, REPEREN-16-2 and decellularized porcine peritoneum on the parietal peritoneum of the pig. Material and methods. At laparoscopy, 6 different meshes were placed intraperitoneally in each of the 3 pigs. After 90 days, the animals were taken out of the experiment. After staining with hematoxylin and eosin, quantitative morphometry and counting the number of vessels and cells in the interstitium in the areas of the mesh and peritoneum were performed. An immunohistochemical study with an antibody to pancytokeratins assessed the state of the initial peritoneum and neoperitoneum. Results. According to morphological characteristics, the meshes were divided into 3 groups: 1) with fluoropolymer coating FTOREX, 2) Ventralight ST and Symbotex, 3) REPEREN and decellularized peritoneum. In group 1, the surface area of the mesh threads was optimal in terms of the arrangement and arrangement of the threads relative to each other. This contributed to the formation of a relatively dense fibrous framework and a place to preserve the underlying peritoneum involved in the formation of the neoperitoneum. Despite the smallest surface area of the threads, in group 3, the greatest fibroblastic reaction was noted. Inflammatory changes were the least pronounced in group 1. They were the greatest in group 3, where there was a pronounced leukocyte reaction, combined with the processes of metaplasia, the development of fibrinoid necrosis, and the progression of the secondary inflammatory process. In group 1, the optimal ratio of newly formed vessels was noted, in group 2 — veins prevailed over arteries, in group 3 — the number of vessels was minimal. Immunohistochemical study showed that in group 1, mesothelial cells covered almost the entire surface of the implant, and there were also areas of preserved basic peritoneum. In group 2, mesothelium also covered most of the surface of the meshes, but the underlying peritoneum was absent. In group 3, on the contrary, a significant number of extended areas not covered with mesothelium were revealed. Conclusion. The conducted morphological and morphometric study showed that the most balanced ratio of the components of the newly formed fibrous tissue and blood vessels is observed when using implants with a fluoropolymer coating FTOREX. At the same time, the remaining basic peritoneum actively participated in the formation of the neoperitoneum. The Ventralight ST and Symbotex meshes also contributed to the formation of a full-fledged fibrous tissue and adequate vascular proliferation, however, they prevented the preservation of the underlying peritoneum, which practically excluded its participation in the formation of the neoperitoneum. The REPEREN mesh and decellularized porcine peritoneum led to the least balanced cell and vascular proliferation and the greatest fibroplastic reaction, which could further negatively affect the state of the formed scar.

6 May 2022 in Siberian journal of oncology
Verified
Journal Article
Open access
PDF file
RPR. V. Pavlov
R. V. Pavlov
KTK. O. Timofeeva
K. O. Timofeeva
MCM. A. Chernykh
M. A. Chernykh
VDV. N. Danilin
V. N. Danilin
Over the past decade, stomach cancer continues to be one of the most common diseases in the world. Currently, the methods of conservative and surgical treatment of this disease are fairly standardized. However, the issue of postoperative management of patients, including the timing of the start of oral nutrition after surgery still remains debatable. In addition, modern methods of treatment are based on the use of protocols for enhanced recovery after surgery, the safety of which remains controversial and requires discussion.Study object was to explore the safety and benefits of early oral nutrition among patients who have undergone gastrectomy for stomach cancer.Material and methods. The authors present their own experience of nutritional support for patients who underwent gastrectomy. The study included 82 patients with locally advanced stomach cancer who received surgical treatment at the n.i. Pirogov clinic of high medical technologies in the period from 2016 to 2019.Results. The safety and positive effect of the use of early oral feeding was proved. It was associated with shorter first exhaust time (2.8 ± 1.0 days vs 3.9 ± 1.2 days, p=0.001), shorter postoperative length of stay in the hospital (5.4 ± 1.5 days vs 9.5 ± 2.3 days; p=0.001), as well as a more dynamic recovery of laboratory parameters.Conclusion. Early per oral nutrition after gastrectomy can reduce the length of hospital stay without increasing the incidence of concomitant complications, which indicates its safety, expediency and potential benefit for patients with gastric cancer.

24 May 2024 in Pirogov Russian Journal of Surgery
Verified
Journal Article
Closed access
ABA.M. Belousov
A.M. Belousov
SNS.L. Nepomnyashchaya
S.L. Nepomnyashchaya
VDV.N. Danilin
V.N. Danilin
KTK.O. Timofeeva
K.O. Timofeeva
VAV.P. Armashov
V.P. Armashov
NMN.L. Matveev
N.L. Matveev
Objective. The purpose of the study was to evaluate the results of using fluoropolymer-coated mesh during intraperitoneal onlay mesh hernia repair in patients with primary ventral hernias. Material and methods. The multicenter, non-randomized, controlled clinical study included 88 patients of both sexes who were operated on using a laparoscopic approach using the IPOM technique for a primary ventral hernia. The duration of observation ranged from 3 to 12 months. In the main group, 48 patients received fluoropolymer-coated meshes (Ftorex). A comparison was made with a retrospective group of 40 patients who were treated with anti-adhesive collagen-coated meshes (Parietene composite, Parietex Composite, Symbotex). Results. The number of early and late postoperative complications in the groups did not have significant differences, at the same time, their number was lower in the group of patients in whom fluoropolymer-coated meshes were used. Most of the complications corresponded to Clavien—Dindo class I and II and did not pose a significant threat to health. There were no recurrences of hernias observed in patients included in the study. There were slightly more adhesions in the fluoropolymer-coated mesh group (35.4% vs. 25.0% in the collagen-coated mesh group). The quality of life of patients in the study groups did not differ. Conclusion. In laparoscopic IPOM hernia repair fluoropolymer-coated meshes are not inferior in effectiveness and safety to traditionally used collagen-coated meshes and can be recommended for use in patients with primary ventral hernias.

26 April 2024 in Endoscopic Surgery
Verified
Journal Article
Closed access
VAV.P. Armashov
V.P. Armashov
ABA.M. Belousov
A.M. Belousov
PPP.A. Potapov
P.A. Potapov
DSD.D. Shkarupa
D.D. Shkarupa
TAT.YU. Anushchenko
T.YU. Anushchenko
NMN.L. Matveev
N.L. Matveev
OBJECTIVE Evaluation of the results of the use of adhesion barrier agents Adept and Mesogel in intraperitoneal onlay mesh repair in the experiment. MATERIAL AND METHODS In 4 pigs during laparoscopy, 24 meshes with fluoropolymer coating Ftorex and with collagen coating Symbotex were fixed on the parietal peritoneum. The meshes were fixed with a SecureStrap hernia stapler or fluoropolymer-coated thread Ftorex. In 2 animals adhesion barriers Adept (4% icodextrin solution) and Mesogel (gel based on carboxymethyl cellulose) were injected into the abdominal cavity. After 45 days, the animals were taken out of the experiment. The number of meshes with inflammation, deformation, retraction, migration of tacks and sutures, mesh area, mechanical strength of mesh fixation, adhesion formation, thickness, breaking load and breaking elongation of the mesh-tissue complex were recorded, histological changes. RESULTS The use of adhesion barriers did not cause a difference in the number of meshes with signs of inflammation, deformation, retraction, mechanical strength of fixation. Tack migration or suture unraveling was not observed. Adhesive barriers reduced mesh retraction. After excision, the area of the mesh in the group without an adhesion barrier was 82.1% of the initial one, with an adhesion barrier — 92.0% (p=0.018). The Ftorex mesh was more susceptible to this process. Adhesion barriers had the advantage of reducing adhesion, but no significant difference was found. The indicators turned out to be somewhat better when using Mesogel. In animals that were injected with adhesion barriers, adhesions to parenchymal and hollow organs were absent. Mesogel did not affect the biomechanical strength of the mesh-tissue complex. Adept resulted in the formation of a thinner mesh-tissue complex (0.6±0.1 mm vs. 0.9±0.0 mm in the Mesogel group, p=0.005) and reduced mean elongation at break (77.4±4.3 mm vs. 91.7±0.7 mm in the Mesogel group, p=0.029). Histological examination showed that when using adhesion barriers over the surface of the peritoneum, the number of connective tissue cords covered with neoperitoneum increases (p=0.024). It cannot be excluded that it is the number of these structures that determines the anti-adhesive properties of the barrier. CONCLUSION In case of intraperitoneal onlay mesh repair, the use of Adept and Mesogel adhesion barriers does not cause clinically significant adverse reactions and complications. The agents have approximately comparable capabilities in the additional prevention of adhesions, however, Adept changes the biomechanical strength of the mesh-tissue complex, which requires further research.