12 November 2013 in IEEE Transactions on Industrial Electronics
An LCL-type filter is widely used in the grid-connected inverter. However, with only injected grid current control, the current harmonics and low bandwidth caused by the resonance peak cannot be tolerated. The active damping (AD) method with an extra feedback provides a high rejection of the resonance so that the dynamic is improved; however, the high-precision sensing circuit for the extra feedback increases the cost. In this paper, with the signal flow graph and response-fitting methods, an AD method based on the feedback of the injected grid current has been proposed. Then, the novel closed-loop current control requires accurately sensing the injected grid current only, while no observation is needed. Compared with the extra feedback methods, the cost and the complexity are reduced while the reliability is improved. Based on the study of the relation between the controller and the system dynamic, a straightforward design has been proposed. The robustness, harmonic rejection, and digital implementation have been studied. Compared with the conventional control methods, the proposed one promises the satisfactory performance with both analog and digital implementations. Simulations and experiments have verified the proposed control and design strategies.
4 March 2021 in IEEE Access
Synchronization is the key part to ensure the high performance of grid-connected systems. Phase-locked loop (PLL) is one of the most popular synchronizations due to its simple implementation and robustness under certain grid variations. Particularly, in single-phase applications, PLL based on second-order generalized integrator (SOGI-PLL) is widely used because of its simple structure, certain filtering ability and frequency adaptability. The sensitivity of SOGI-PLL to the dc offset and low-order harmonics has been studied a lot in the literature and many solutions have been proposed. However, as more and more power electronic devices are integrated into the power grid recently, the grid condition becomes more complex. As a result, the nonlinear loop coupling phenomenon of SOGI-PLL is more severe and obvious and thus the performance of SOGI-PLL is degraded a lot, especially under the conditions of grid frequency variations and weak grid. A popular method is to use the frequency-fixed SOGI-PLL (FFSOGI-PLL) while how to eliminate the estimation error under frequency variations remain an important task. Though some scattered methods have been proposed, a simple yet effective strategy is still missing. Besides, it has been shown that the system stability margin will be reduced due to the negative-resistance behavior of PLL. However, the models derived in the current documents cannot accurately reveal the instabilities caused by the standard SOGI-PLL for missing the dynamics of the frequency feedback loop. Moreover, the PLL parameters are usually designed according to the PLL bandwidth to guarantee system stability under a weak grid. How to optimize the parameters is still unclear. In view of this, this article further summarizes and reviews the existing achievements of single-phase SOGI-PLL, and points out the problems to be solved and the development direction to improve the SOGI-PLL under more complex and non-ideal grid conditions.
1 October 2014 in IET Power Electronics
In grid‐connected LCL‐filtered inverters, the dual‐loop current control is widely used. The LCL resonance is highly damped by proper feedback of the capacitor current. To suppress low‐frequency current harmonics, a grid‐voltage feedforward is commonly used. However, the system performance with such control is declined when connecting to a weak grid. Phase and gain margins are largely reduced while the proportional feedforward is used. The margins get worse and instability is aroused if the derivative feedforward is further implemented. Besides, a negative impact on the rejection of grid‐voltage‐induced harmonics is produced. To improve the control performance in the weak grid case, an adaptive control has been proposed. Adopting the estimated grid impedance, the signal for the grid‐voltage feedforward is modified and the controller is adjusted with an adaptive rule to maintain a good phase margin or a high bandwidth. Performances of the inverter with the typical and the proposed methods are compared. Simulation and experimental results have demonstrated that the grid‐connected LCL‐filtered inverter with the proposed method produced a high‐quality current while large grid impedance existed.
1 February 2013 in IET Power Electronics
For grid‐connected inverters, switching harmonics can be effectively attenuated through an LCL‐type filter. In order to suppress resonance and guarantee good performance, many strategies (e.g. active damping (AD), harmonic resonant control, repetitive control and grid feedforward) have been proposed. However, the wide variation of grid impedance value challenges system stability in practical applications. The aforementioned methods need to be investigated. This study evaluates the applicability of each part of the overall control in a weak grid case with the use of a stability criterion. It has been demonstrated that the feedback‐based AD control can work well in a wide range of grid conditions. However, the resonant and repetitive control methods meet constraints. The grid feedforward method brings in an extra positive feedback path, and consequently results in high harmonics or even instability. Finally, a recommendation for system design has been presented. Simulations and experiments have been provided to verify the analysis.
17 January 2019 in IEEE Transactions on Sustainable Energy
In the distributed power generation systems (DPGSs) based on the renewable energies, the stability and harmonics of the grid-connected inverter are seriously affected by the uncertainties of the grid at the point of common coupling (PCC). More importantly, as several inverters are usually tied at the PCC together, the interactions among the inverters and the grid impedance can cause more serious harmonics and instabilities at the low frequencies. Hence, the phase-locked loop (PLL) affecting the low-frequency behaviors must be considered. This study aims to provide a comprehensive study of the stability and harmonics of single-phase inverters in the weak grid. Modellings of single-inverter and multiple-inverters systems considering the PLL are established. The impacts of different PLLs on the low-order current harmonics and stability are then studied. It has been proved that the maximum ability of inverters in suppressing the low-order grid current harmonics closely relates to the PLL, even if a harmonic resonant controller and/or PCC voltage feedforward is used. Thus, using different PLLs yields quite different performances. Simulation and experimental results will be given to demonstrate the analysis which is helpful for readers to design a proper PLL for DPGSs.
2 June 2017 in IEEE Transactions on Industrial Electronics
The performance of the grid-connected inverter was affected by the uncertainty of the grid conditions including the background distortion and the grid impedance. Typically, the feedforward of the grid voltage at the point of common coupling (PCC) highly suppressed the grid current harmonics caused by the grid voltage distortion; however, the PCC grid usually had a nonnegligible grid impedance, and the PCC voltage feedforward aroused serious grid current harmonics or instability. This study proposes a novel adaptive algorithm for the PCC voltage feedforward to work well with the varied grid impedance. In the proposal, the band-pass filters at the harmonic frequencies are used to detect the variation of the grid impedance as well as to facilitate the adaptive PCC voltage feedforward. It is not necessary to inject an additional harmonic to estimate the grid impedance. The basic principles as well as the realization and logic of the proposed algorithm are detailed, and some selected waveforms are provided to verify the superior performance. Compared with the typical robust design or adaptive control, the proposed algorithm does not have to sacrifice the dynamic or the harmonics rejection performance, or to use the on or offline grid impedance estimation.