Dong Liang

Dong Liang

Auto-generated profile, based on publicly available information

Dong Liang

Sichuan University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

4 December 2025 in Energy Conversion and Management
Verified
Journal Article
Closed access
DLDong Liang
Dong Liang
ZZZhiqiang Zeng
Zhiqiang Zeng
DZDawei Zhuang
Dawei Zhuang
BLBoxuan Li
Boxuan Li
SYShuhuai Yao
Shuhuai Yao

11 March 2026 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
SWShirui Wang
Shirui Wang
SLShujia Li
Shujia Li
JPJunce Pu
Junce Pu
DLDong Liang
Dong Liang
WCWei Chen
Wei Chen
MCMinking K. Chyu
Minking K. Chyu

16 May 2026 in Software Impacts
Verified
Journal Article
Open access
JPJunce Pu
Junce Pu
CTChenning Tang
Chenning Tang
CXChen Xu
Chen Xu
DLDong Liang
Dong Liang
MCMinking K. Chyu
Minking K. Chyu

4 August 2025 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
MLMingfei Li
Mingfei Li
MRMumin Rao
Mumin Rao
XLXiaolong Li
Xiaolong Li
DLDong Liang
Dong Liang
WCWei Chen
Wei Chen
Truss-type lattice structures exhibit great application potential for turbine blade cooling. However, current research on lattice structures is limited to rectangular cooling channels, leaving their heat transfer characteristics in the wedge-shaped channels of turbine blades unclear. This study employed transient liquid crystals (TLC) technique and numerical simulations to investigate the flow and heat transfer characteristics of Kagome and Body Centered Cubic (BCC) lattice structures within a wedge-shaped channel, representing the trailing edge of a turbine blade. Results from a traditional pin-fin channel were used as a comparison benchmark. The findings indicate that the decrease in the height of the wedge-shaped channels along the flow direction leads to mainstream acceleration, resulting in a continuous enhancement of heat transfer on the channel walls. Unlike rectangular channels, the pressure loss caused by the lattice structures in the wedge-shaped channels is comparable to that of the pin fins, thereby improving the overall thermal efficiency. Additionally, the unique topology of the Kagome lattice structure causes low-momentum vortex pairs behind its central intersection to continuously rise in the wedge-shaped channel, ultimately washing over the top endwall and resulting in a linear increase in the heat transfer level. Overall, this study reveals that replacing pin fins with lattice structures at the turbine trailing edge can enhance the cooling performance without significantly impacting the pumping power.

20 July 2021 in JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Verified
Journal Article
Closed access
PDF file
LDLiang Dong
Liang Dong
JGJinnan Guo
Jinnan Guo
JLJiawei Liu
Jiawei Liu
HLHoulin LIU
Houlin LIU
CDCui Dai
Cui Dai
The aeration performance of inverted umbrella aerator is optimized through response surface methodology. The Box-Behnken design (BBD) method is used to design the experimental scheme, and three variables (blade number, plate tilt angle and plate gap opening) are selected to optimize the structure of the inverted umbrella aerator impeller and improve the aeration performance. The corresponding response value is obtained by experiments through the established scheme. The regression model is fitted through the response value, and the variance analysis is performed on the regression model to test the significance of the model. The results show that the P-value is less than 0.05. Therefore, the model is significant and fits well in the regression area. The effect of the blade number and the plate tilt angle on the target is significant, while plate gap opening is not significant. The inverted umbrella aerator has the best aeration performance when the number of the blades is 6, the plate tilt angle is 65° and the plate gap opening is 16.07%. The aeration performance and flow field before and after optimization are compared. It shows that the standard oxygen mass transfer coefficient after optimization increases by 1.59%, and the standard aeration efficiency increases by 4.78%. The flow becomes more intense after optimization. The oxygen mass transfer process is further strengthened, and the aeration performance of inverted umbrella aerator is optimized.