Jee Won Shin

Jee Won Shin

Auto-generated profile, based on publicly available information

Jee Won Shin

Medical Scientist Training Program, Mayo Clinic, Rochester, Minnesota, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2020 in npj Regenerative Medicine
Verified
Journal Article
Open access
PDF file
NKNatalia Kosyakova
Natalia Kosyakova
DKDerek D. Kao
Derek D. Kao
MFMaria Figetakis
Maria Figetakis
FLFrancesc López-Giráldez
Francesc López-Giráldez
SSSusann Spindler
Susann Spindler
WCWilliam G. Chang
William G. Chang
Formation of a perfusable microvascular network (μVN) is critical for tissue engineering of solid organs. Stromal cells can support endothelial cell (EC) self-assembly into a μVN, but distinct stromal cell populations may play different roles in this process. Here we describe the differential effects that two widely used stromal cell populations, fibroblasts (FBs) and pericytes (PCs), have on μVN formation. We examined the effects of adding defined stromal cell populations on the self-assembly of ECs derived from human endothelial colony forming cells (ECFCs) into perfusable μVNs in fibrin gels cast within a microfluidic chamber. ECs alone failed to fully assemble a perfusable μVN. Human lung FBs stimulated the formation of EC-lined μVNs within microfluidic devices. RNA-seq analysis suggested that FBs produce high levels of hepatocyte growth factor (HGF). Addition of recombinant HGF improved while the c-MET inhibitor, Capmatinib (INCB28060), reduced μVN formation within devices. Human placental PCs could not substitute for FBs, but in the presence of FBs, PCs closely associated with ECs, formed a common basement membrane, extended microfilaments intercellularly, and reduced microvessel diameters. Different stromal cell types provide different functions in microvessel assembly by ECs. FBs support μVN formation by providing paracrine growth factors whereas PCs directly interact with ECs to modify microvascular morphology.

18 November 2024 in Operative Neurosurgery
Verified
Journal Article
Closed access
JSJee Won Shin
Jee Won Shin
KSKristen M. Scheitler
Kristen M. Scheitler
BSBasel A. Sharaf
Basel A. Sharaf
IMIan Mandybur
Ian Mandybur
SHSara M Hussein
Sara M Hussein
KLKendall H. Lee
Kendall H. Lee
BACKGROUND AND OBJECTIVES: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation. In this article, we aim to evaluate the compatibility of the stereotactic frame system with the intraoperative O-arm system regarding lead accuracy and surgical flow. METHODS: A total of 17 patients undergoing DBS surgery for movement disorders were evaluated. One patient underwent both the stereotactic CT and O-arm localization, while 16 patients underwent only intraoperative O-arm localization. Following lead placement, intraoperative O-arm imaging was obtained to evaluate the accuracy of the lead placement. Accuracy was defined as the error measured as the distance from the center of the planned trajectory to the cannula. RESULTS: Less than 0.1 mm difference was found between the O-arm imaging technique and CT image localization of the NaviNetics stereotactic head frame in DBS surgery. Of the 16 patients who underwent the intraoperative O-arm imaging alone, the targets included bilateral ventral intermediate nucleus (16 leads), bilateral globus pallidus internus (4 leads), and subthalamic nucleus (12 leads). The mean ± SD radial error in the probe's eye view was 0.71 ± 0.33 mm for n = 32 leads. No tract hemorrhage was observed. CONCLUSION: Intraoperative O-arm imaging can be used safely and effectively for stereotactic registration and lead placement confirmation with the stereotactic system in both awake and asleep DBS surgery.