Mathias Donnez

Mathias Donnez

Auto-generated profile, based on publicly available information

Mathias Donnez

Aix Marseille Univ, CNRS, ISM, Marseille, France

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
MMM. Munier
M. Munier
MDM. Donnez
M. Donnez
MOM. Ollivier
M. Ollivier
XFX. Flecher
X. Flecher
PCP. Chabrand
P. Chabrand
SPSébastien Parratte
Sébastien Parratte

9 July 2018 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
MDMathias Donnez
Mathias Donnez
MOMatthieu Ollivier
Matthieu Ollivier
MMMaxime Munier
Maxime Munier
PBPhilippe Berton
Philippe Berton
JPJean-Pierre Podgorski
Jean-Pierre Podgorski
SPSébastien Parratte
Sébastien Parratte
The aim of this in vitro study was to assess the accuracy of three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy (OWHTO) to provide the planned correction in both frontal and sagittal planes. Ten cadaveric tibias underwent OWHTO performed using a patient-specific cutting guide based on 3D preoperative planning. An initial CT scan of the tibias was performed, and after segmentation, 3D geometrical models of the pre-OWHTO tibias were obtained. Reference planes were defined, and OWHTO virtually planned to then design patient-specific cutting guides. OWHTO were performed using the patient-specific cutting guides. The patient-specific cutting guide controls the cut and the correction of the OWHTO in both planes. 3D models of post-OWHTO tibias were created after a postoperative CT scan. Geometrical post-OWHTO 3D models were superimposed on pre-OWHTO 3D models. Mechanical medial proximal tibial angle (mMPTA) in the frontal plane and posterior tibial slope (PTS) in the sagittal plane were compared between planned-OWHTO and post-OWHTO 3D reconstructions relative to the pre-OWHTO reference planes and axis. Pearson’s and Lin’s correlation tests were performed to assess precision and accuracy of patient-specific cutting guides. The mean difference between post-OWHTO and planned-OWHTO was 0.2° (max 0.5°, SD 0.3°) in the frontal plane and − 0.1° (max 0.8°, SD 0.5°) in the sagittal plane. Statistically significant correlations were found between the planned-OWHTO and post-OWHTO configurations for the mMPTA (p < 0.0001) and PTS (p < 0.0001) measurements, and the bias correction factor was 0.99 in both planes. 3D patient-specific cutting guides for OWHTO-based 3D virtual planning is a reliable and accurate method of achieving multiplanar correction in both frontal and sagittal planes.

1 May 2018 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
JEJ.-C. Escudier
J.-C. Escudier
MOMatthieu Ollivier
Matthieu Ollivier
MDM. Donnez
M. Donnez
SPS. Parratte
S. Parratte
PLP. Lafforgue
P. Lafforgue
JAJ.-N. Argenson
J.-N. Argenson