The Ruczaj district in Kraków is the potential building area of high flat blocks for inhabitants. This area is built of the gypsum basement covered by the soil and impermeable clay beds with several meters of thickness. The flat blocks must be set on the textured gypsum layer. In the result of the rainfall and static pressure of the blocks, the water with SO42− increases up to the groundwater level, become the great threat for the flat blocks. The water creates specific hydrogeological conditions occurring in the zone of the building’s foundations. To eliminate the mentioned threat, we should determine precisely the thickness of the soil and impermeable clay as well as the depth of the gypsum basement. Based on the electromagnetic parameters of the geological formations, the Ground Conductivity Meter and DC resistivity methods were used to solve the mentioned problems.
In 2011, a geophysical survey was carried out in the surroundings of the Jagiellonian University in Cracow, using a Very Low Frequency method. The measurements were designed to determine the reason of frequent flooding of the lowest level of the building. The main objective of the study was to find out from where and in which way the rainwater seeps into the building and how this problem can be solved in the least invasive manner. The aim of geophysical methods was also to provide necessary information that will enable the construction of a hydro-geological model of the local environment. The interpretation revealed the presence of a sandy gutter surrounded by impermeable clay. There is a big resistivity contrast between those layers. Their location and approximate dimensions were determined.
This paper presents an assessment of the potential usefulness of the Ground Conductivity Meter (GCM) method to locate seepage pathways in the Maniow levee zone near Kraków, Poland. We have realized this aim through geological recognition of the study area, which requires the implementation of GCM data inversion measured in the sounding version. The GCM measurements were performed along with the net of profiles using combined data from CMD Mini Explorer and CMD Explorer equipment. The methodology of the one-dimensional (1D) inversion of the GCM soundings located along profiles is presented in the article. The legitimacy of the inversion and the relationship of the results obtained in the form of conductivity sections along profiles with geology have been verified in detail. The inversion procedures were tested on the synthetic GCM soundings obtained from modeling processes, by using the electrical conductivity and thicknesses, known from the drilled formations and additionally based on DC-R sounding data. These soundings were performed at some selected reference points in the levee zone. We have used our software and IX1D Interpex software to calculate the forward modeling. Quantitative interpretation processed along the profiles has been proceeded by 1D inversion of GCM data at several referential points located close to boreholes and DC soundings. It was done to verify the correctness of the quantitative interpretation. The geoelectrical models, obtained in a section form, were correlated with the borehole lithology data, providing a reference geological structure in some places. As a result of the work mentioned above, the potential seepage zones were located on the conductivity sections. The thickness of the cohesive silty clay layer, lying near to the surface, in the seepage zones, was thin enough and less than a meter. When the water level in the Vistula river was high enough, water can flow in the noncohesive gravel layer occurring directly below the silty clays and lead to flooding on the landward side of the dams in the Maniow region.
Effectiveness of transient electromagnetic method (TEM) used for the localization of Pb–Zn ore bodies at the Cho Don deposit, province Bac Can, North Vietnam is appraised based on the modelling processes results. Conductive Pb–Zn ore bodies hosted in high-resistive limestone are in good conditions for the application of the TEM. The modelling process relays on the calculation of the voltage decay in time domain formed from the induced magnetic field diffusing into the study medium, when a pulse current with a given frequency is flowing in a transmitting loop coil. The model results show that the power current of 1 A transmitted from the coils with 100 or 400 m of size is effective for localization of the Zn–Pb ore bodies. However, the resolution and penetration depth of the TEM with a coil of L = 100 m is better and shorter in comparison with those in the case using the coil L = 400 m.