Muhammad H. E. ElHansy

Muhammad H. E. ElHansy

Auto-generated profile, based on publicly available information

Muhammad H. E. ElHansy

Clinical Pharmacy Department, Teaching Hospital of Faculty of Medicine, Faculty of Medicine, Fayoum University, Fayoum, Egypt

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2017 in Pulmonary Pharmacology & Therapeutics
Verified
Journal Article
Closed access
MEMuhammad H.E. ElHansy
Muhammad H.E. ElHansy
MBMarina E. Boules
Marina E. Boules
AEAssem Fouad Mohamed El Essawy
Assem Fouad Mohamed El Essawy
MAMohamed Bakry Al-Kholy
Mohamed Bakry Al-Kholy
MAMaha M. Abdelrahman
Maha M. Abdelrahman
MAMohamed Abdelrahim
Mohamed Abdelrahim

1 August 2017 in Pulmonary Pharmacology & Therapeutics
Verified
Journal Article
Closed access
IMIslam O.F. Moustafa
Islam O.F. Moustafa
MEMuhammad H.E. ElHansy
Muhammad H.E. ElHansy
MHMoataz Al Hallag
Moataz Al Hallag
JFJames B. Fink
James B. Fink
PDPatricia Dailey
Patricia Dailey
MAMohamed Abdelrahim
Mohamed Abdelrahim

18 August 2016 in Pharmaceutical Development and Technology
Verified
Journal Article
Closed access
MEMuhammad H. E. ElHansy
Muhammad H. E. ElHansy
MBMarina E. Boules
Marina E. Boules
HFHeba Farid
Heba Farid
HCHenry Chrystyn
Henry Chrystyn
SESameh Kamal El-Maraghi
Sameh Kamal El-Maraghi
MAMohamed Abdelrahim
Mohamed Abdelrahim
Aerodynamic characteristics of aerosol delivery during invasive mechanical ventilation (IMV) are mostly determined by inserting cascade impactor in the circuit. Impactor might have some effect on airflow within IMV. Hence, the aim of the present study was to develop and evaluate new in vitro aerodynamic characterization methodology without affecting airflow in IMV. Breathing simulator was set in standard adult IMV circuit with inspiratory and expiratory pressures of 20 and 5 cm H2O, 1:3 inspiratory–expiratory ratio, 15 breaths min−1, and tidal volume of 500 ml. Two ml of salbutamol solution containing 10,000 μg was nebulized using three different vibrating mesh nebulizers (VMNs) and Sidestream jet nebulizer (JET). Sixteen-metered doses, containing 100 μg salbutamol each, were delivered using three different spacers. Each device was placed in inspiration limb of Y-piece of ventilator tubing. Aerodynamic characteristics of aerosol delivered were measured using cooled Andersen cascade impactor, with mixing inlet connected to it. VMNs used had significantly more total mass in the impactor (p < .001) and fine particle dose (p < .001) compared to JET. Spacers used had higher total mass in the impactor percent (p < .001) and fine particle fraction compared to nebulizers. The in vitro IMV methodology setting suggested here showed encouraging results in comparison of different aerosol delivery systems in intubated patient.