Daniel Forsberg

Daniel Forsberg

Auto-generated profile, based on publicly available information

Daniel Forsberg

Sectra, Teknikringen 20, SE-583 30, Linköping, Sweden.

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2013 in Medical Image Analysis
Verified
Journal Article
Closed access
AEAnders Eklund
Anders Eklund
PDPaul Dufort
Paul Dufort
DFDaniel Forsberg
Daniel Forsberg
SLStephen M. LaConte
Stephen M. LaConte

7 January 2015 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JSJ Sjölund
J Sjölund
DFD Forsberg
D Forsberg
MAM Andersson
M Andersson
HKH Knutsson
H Knutsson
Radiotherapy planning and attenuation correction of PET images require simulation of radiation transport. The necessary physical properties are typically derived from computed tomography (CT) images, but in some cases, including stereotactic neurosurgery and combined PET/MR imaging, only magnetic resonance (MR) images are available. With these applications in mind, we describe how a realistic, patient-specific, pseudo-CT of the head can be derived from anatomical MR images. We refer to the method as atlas-based regression, because of its similarity to atlas-based segmentation. Given a target MR and an atlas database comprising MR and CT pairs, atlas-based regression works by registering each atlas MR to the target MR, applying the resulting displacement fields to the corresponding atlas CTs and, finally, fusing the deformed atlas CTs into a single pseudo-CT. We use a deformable registration algorithm known as the Morphon and augment it with a certainty mask that allows a tailoring of the influence certain regions are allowed to have on the registration. Moreover, we propose a novel method of fusion, wherein the collection of deformed CTs is iteratively registered to their joint mean and find that the resulting mean CT becomes more similar to the target CT. However, the voxelwise median provided even better results; at least as good as earlier work that required special MR imaging techniques. This makes atlas-based regression a good candidate for clinical use.

1 April 2016 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
JYJianhua Yao
Jianhua Yao
JBJoseph E. Burns
Joseph E. Burns
DFDaniel Forsberg
Daniel Forsberg
ASAlexander Seitel
Alexander Seitel
ARAbtin Rasoulian
Abtin Rasoulian
SLShuo Li
Shuo Li

12 January 2017 in Journal of Digital Imaging
Verified
Journal Article
Closed access
PDF file
DFDaniel Forsberg
Daniel Forsberg
ESErik Sjöblom
Erik Sjöblom
JSJeffrey L. Sunshine
Jeffrey L. Sunshine

1 January 2017 in Medical Image Analysis
Verified
Journal Article
Closed access
Guoyan ZhengGuoyan Zheng
Guoyan Zheng
CCChengwen Chu
Chengwen Chu
DBDaniel Belavy
Daniel Belavy
BIBulat Ibragimov
Bulat Ibragimov
RKRobert Korez
Robert Korez
SLShuo Li
Shuo Li

26 February 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DFDaniel Forsberg
Daniel Forsberg
CLClaes Lundström
Claes Lundström
MAMats Andersson
Mats Andersson
LVLudvig Vavruch
Ludvig Vavruch
HTHans Tropp
Hans Tropp
HKHans Knutsson
Hans Knutsson
Reliable measurements of spinal deformities in idiopathic scoliosis are vital, since they are used for assessing the degree of scoliosis, deciding upon treatment and monitoring the progression of the disease. However, commonly used two dimensional methods (e.g. the Cobb angle) do not fully capture the three dimensional deformity at hand in scoliosis, of which axial vertebral rotation (AVR) is considered to be of great importance. There are manual methods for measuring the AVR, but they are often time-consuming and related with a high intra- and inter-observer variability. In this paper, we present a fully automatic method for estimating the AVR in images from computed tomography. The proposed method is evaluated on four scoliotic patients with 17 vertebrae each and compared with manual measurements performed by three observers using the standard method by Aaro-Dahlborn. The comparison shows that the difference in measured AVR between automatic and manual measurements are on the same level as the inter-observer difference. This is further supported by a high intraclass correlation coefficient (0.971-0.979), obtained when comparing the automatic measurements with the manual measurements of each observer. Hence, the provided results and the computational performance, only requiring approximately 10 to 15 s for processing an entire volume, demonstrate the potential clinical value of the proposed method.