Celina Lumi Kushida

Celina Lumi Kushida

Auto-generated profile, based on publicly available information

Celina Lumi Kushida

Department of Intensive Care Unit, ENCORE Hospital, Aparecida de Goiânia, Goiás, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Brazilian Journal of Cardiovascular Surgery
Verified
Journal Article
Open access
GEGustavo Siqueira Elmiro
Gustavo Siqueira Elmiro
ASArtur Henrique de Souza
Artur Henrique de Souza
SLStanlley de Oliveira Loyola
Stanlley de Oliveira Loyola
MPMaurício Lopes Prudente
Maurício Lopes Prudente
CKCelina Lumi Kushida
Celina Lumi Kushida
GGGiulliano Gardenghi
Giulliano Gardenghi
The delayed extubation of patients undergoing mechanical ventilation (MV) in the postoperative period of cardiac surgery (CS) is associated with mortality. The adoption of spinal anesthesia (SA) combined with general anesthesia in CS influences the orotracheal intubation time (OIT). This study aims to verify if the adoption of SA reduces the time of MV after CS, compared to general anesthesia (GA) alone. Two hundred and seventeen CS patients were divided into two groups. The GA group included 108 patients (age: 56±1 years, 66 males) and the SA group included 109 patients (age: 60±13 years, 55 males). Patients were weaned from MV and, after clinical evaluation, extubated. In the SA group, considering a 13-month period, 24% of the patients were extubated in the operating room (OR), compared to 10% in the GA group (P=0.00). The OIT was lower in the SA group than in the GA group (SA: 4.4±5.9 hours vs. GA: 6.0±5.6 hours, P=0.04). In July/2017, where all surgeries were performed in the GA regimen, only 7.1% of the patients were extubated in the OR. In July/2018, 94% of the surgeries were performed under SA, and 64.7% of the patients were extubated in the OR (P=0.00). The OIT on arrival at the intensive care unit to extubation, comparing July/2017 to July/2018, was 5.3±5.3 hours in the GA group vs. 1.7±3.9 hours in the SA group (P=0.04). The adoption of SA in CS increased the frequency of extubations in the OR and decreased OIT and MV time.

10 May 2019 in Revista Pesquisa em Fisioterapia
Verified
Journal Article
Open access
PDF file
GGGiulliano Gardenghi
Giulliano Gardenghi
CKCelina Lumi Kushida
Celina Lumi Kushida
ADAbissay Francisco Dias
Abissay Francisco Dias
JCJessyka Bueno Cruz
Jessyka Bueno Cruz
KLKassiely Ribeiro De Lima
Kassiely Ribeiro De Lima
ASArtur Henrique De Souza
Artur Henrique De Souza
INTRODUCTION: The use of a cycle ergometer for the upper limbs may contribute to maintain the functional capacity in patients after heart surgery (HS). OBJECTIVES: To investigate the cardiorespiratory responses of HS patients receiving or not vasoactive drugs (VADs) during the realizations of cycle ergometer for upper limbs, verifying the incidence of loss of radial arterial catheter or of steel wire fractures in the sternum. MATERIAL AND METHODS: A pilot study involving 26 patients divided in 2 groups. Group CO: no use of VADs (13 patients, age: 57±12 years, 09 male) and VAD group: (13 patients, age: 61±10 years, 07 male), submitted to HS, which on the first postoperative day (1stPO) performed the cycle ergometer for upper limbs. The parameters evaluated during the exercise were heart rate (HR), oxygen saturation (SpO2), dyspnea, fatigue of upper limbs and mean arterial pressure (MAP). The incidence of losses of the radial artery catheter and of steel wire fractures in the sternum was calculated. Statistical analysis adopted one-way or two-way analysis of variance, with post hoc from Newman Kauls or Scheffé, when necessary. The significance level was 0.05%. RESULTS: HR increased in both groups at the end of the exercise (p=0.00), with no difference between them (p=0.97); SpO2, dyspnea and MAP did not change from rest to the end of exercise (p=0.49; p=0.78 and p=0.25, respectively); The fatigue in the upper limbs increased in both groups (p=0.04), without difference between groups (p=0.79); There was no event of loss of radial artery catheter or steel wire fractures in the sternum. CONCLUSION: The adoption of the cycle ergometer for upper limbs was safe in the 1stPO of HS, even in the individuals using VADs. There was no relationship between the use of the upper limbs cycle ergometer and losses of arterial catheters or steel wire fractures in the sternum.