Jiahui Yin

Jiahui Yin

Auto-generated profile, based on publicly available information

Jiahui Yin

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2013 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
HWHao Wei
Hao Wei
FSFengju Sun
Fengju Sun
AQAici Qiu
Aici Qiu
JZJiangtao Zeng
Jiangtao Zeng
JYJiahui Yin
Jiahui Yin
YHYixiang Hu
Yixiang Hu
In this paper, a full-size 3-D electromagnetic model (without electrons) and an equivalent circuit model of a single cell in magnetically insulated induction voltage adders has been established. The simulation results of these two models agree well with each other. On the basis of these two models, azimuthal transmission lines for a cell driven by two pulse forming lines (PFLs) have been optimized. The optimization process aims at matching the impedance to the feed PFLs, ensuring uniform potential distribution along the insulator-stack, maximizing the symmetric current flow around the bore, and minimizing the waveform distortion of the injected pulse. A formula is presented to estimate the azimuthal impedance and an asymmetric coefficient is also defined to quantify the asymmetric extent of the feed pulses. The profiles of the total four candidate azimuthal lines have been simulated and analyzed. The simulation results indicate a relatively low feed asymmetry for all the four profiles. However, considering the waveform quality of the cell output voltage, the azimuthal line profiles with four points connected or wholly connected to the cathode plate are the most suitable for induction cells with two PFL feeding. And the corresponding coefficients $\delta$ are 3.1% and 7.6%, respectively. It is concluded that, when optimizing azimuthal lines for cells with two PFL feeding, the principal consideration should be matching the impedance instead of symmetrizing the current flow.

18 November 2011 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
PLPeng Liu
Peng Liu
FSFengju Sun
Fengju Sun
HWHao Wei
Hao Wei
XJXiaofeng Jiang
Xiaofeng Jiang
XLXuandong Liu
Xuandong Liu
AQAici Qiu
Aici Qiu
In this paper, the circuit model capable of dealing with magnetizing characteristics of the magnetic cores and switch prefire is established for linear transformer driver (LTD) cavities in PSPICE. Through simulation, the effects of switch prefire on other components in LTD and its output current pulse have been analyzed associated with the variation of energy loss in magnetic cores. Simulation results indicate that a switch prefire in one cavity would produce oscillations added to the charge voltage of the other switches in this cavity and cavities adjacent immediately. The magnitudes of such oscillations have an intimate relation with the magnetic core loss equivalent resistance. The loss equivalent resistances in the range from 4 to 6 have produced moderate voltage oscillations. Experiments on the 300-kA LTD cavity developed by the Northwest Institute of Nuclear Technology proved that such oscillations added to the charge voltage of other switches are likely to increase the breakdown probability of them.

1 July 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JYJiahui Yin
Jiahui Yin
FSFengju Sun
Fengju Sun
XJXiaofeng Jiang
Xiaofeng Jiang
ZWZhiguo Wang
Zhiguo Wang
TLTianxue Liang
Tianxue Liang
AQAici Qiu
Aici Qiu
It is difficult to feed the trigger pulse into an electrically triggered mega-volt switch, and the present note presents a novel trigger pulse feed method. The trigger pulse is introduced via a damping resistor, which is mounted between the inner and outer cylindrical electrodes of the pulse transmission line. The mega-volt pulse is damped because the voltage is resistively divided by the resistor and trigger cable arrangement. Both the complex breakdown processes of the switch and its insulation issues are experimentally studied. The function and the beneficial effects of the damping resistor, installed together with an additional inductor, are discussed. Finally, the parameters of these two damping components are set to 500 Ω and 2 μH values for which the switch has been demonstrated to work successfully at over 2.3 MV.

12 June 2013 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
JYJiahui Yin
Jiahui Yin
PLPeng Liu
Peng Liu
HWHao Wei
Hao Wei
FSFengju Sun
Fengju Sun
AQAici Qiu
Aici Qiu
In this paper, a triggering method based on secondary induced overvoltage for a linear transformer driver (LTD) is proposed and investigated by simulation. A detailed circuit model established for the LTD is chosen to study the effect of some factors on the feasibility of this triggering method. The considered factors include the permeability, equivalent resistance of energy loss, saturation of magnetic cores, and the delay of gas switches in LTD cavities. Simulation results indicate that high equivalent resistance and high permeability of magnetic cores are helpful in realizing this trigger method. However, the resistance plays a leading role. An equivalent resistance of more than 1.5 Ω favors the realization of this trigger. However, a relative permeability of even 25 has not produced a fatal menace to this triggering method. The feasibility of this triggering necessitates the available volt-second product of the present magnetic cores to be expanded twice. As for gas switches, the interval given by secondary induced overvoltage would likely be long enough to complete their breakdown. From simulation results, it is shown that LTD switches could be rapidly closed under the action of such an overvoltage pulse with a rise time of less than 10 ns.

1 March 2015 in Plasma Science and Technology
Verified
Journal Article
Closed access
HWHao Wei
Hao Wei
FSFengju Sun
Fengju Sun
JYJiahui Yin
Jiahui Yin
YHYixiang Hu
Yixiang Hu
TLTianxue Liang
Tianxue Liang
AQAici Qiu
Aici Qiu

1 September 2014 in Plasma Science and Technology
Verified
Journal Article
Closed access
YHYixiang Hu
Yixiang Hu
JZJiangtao Zeng
Jiangtao Zeng
FSFengju Sun
Fengju Sun
HWHao Wei
Hao Wei
JYJiahui Yin
Jiahui Yin
AQAici Qiu
Aici Qiu