Christian May

Christian May

Auto-generated profile, based on publicly available information

Christian May

Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SBStefan Bauer
Stefan Bauer
CMChristian May
Christian May
DDDimitra Dionysiou
Dimitra Dionysiou
GSGeorgios Stamatakos
Georgios Stamatakos
PBPhilippe Büchler
Philippe Büchler
MRMauricio Reyes
Mauricio Reyes
Image-based modeling of tumor growth combines methods from cancer simulation and medical imaging. In this context, we present a novel approach to adapt a healthy brain atlas to MR images of tumor patients. In order to establish correspondence between a healthy atlas and a pathologic patient image, tumor growth modeling in combination with registration algorithms is employed. In a first step, the tumor is grown in the atlas based on a new multiscale, multiphysics model including growth simulation from the cellular level up to the biomechanical level, accounting for cell proliferation and tissue deformations. Large-scale deformations are handled with an Eulerian approach for finite element computations, which can operate directly on the image voxel mesh. Subsequently, dense correspondence between the modified atlas and patient image is established using nonrigid registration. The method offers opportunities in atlas-based segmentation of tumor-bearing brain images as well as for improved patient-specific simulation and prognosis of tumor progression.

20 June 2018 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
CMChristian May
Christian May
MEMike Egloff
Mike Egloff
ABAndre Butscher
Andre Butscher
MKMarius Johann Baptist Keel
Marius Johann Baptist Keel
TAThis Aebi
This Aebi
Johannes Dominik BastianJohannes Dominik Bastian
Johannes Dominik Bastian
Background: In elderly patients who have sustained an acetabular fracture involving disruption of the quadrilateral plate (QLP), postoperative loading of the joint beyond the level of partial weight-bearing can result in medial redisplacement of the QLP. The purpose of this biomechanical study was to compare the performances of 4 different fixation constructs intended to prevent medial redisplacement of the QLP. Methods: Anterior column posterior hemitransverse (ACPHT) fractures with disruption of the QLP were created on synthetic hemipelves (fourth-generation Sawbones models) and subsequently stabilized with (1) a 12-hole plate bridging the QLP (Group 1), (2) the plate with added periarticular screws along the QLP (Group 2), (3) the plate combined with an infrapectineal buttress plate (Group 3), or (4) the plate with the added periarticular screws as well as the buttress plate (Group 4). The point of load application on the acetabulum was defined to be the same as the point of application of maximum vertical hip contact force during normal walking. Loads were applied to simulate either partial weight-bearing (20 cycles, from 35 to 350 N) or inadvertent supraphysiologic loads (linearly increasing loads until the onset of failure, defined as fragment displacement of >3 mm). A universal testing machine was synchronized with a digital image correlation system to optically track redisplacement at the QLP. The level of significance was set at p < 0.05. Results: During experimental simulation of partial weight-bearing, maximum fracture step openings never exceeded 2 mm. During simulation of inadvertent supraphysiologic load, the median load to failure was higher (p < 0.05) in Group 2 (962 N; range, 798 to 1,000 N) and Group 4 (985 N; range, 887 to 1,000 N) compared with Group 1 (445 N; range, 377 to 583 N) and Group 3 (671 N; range, 447 to 720 N). Conclusions: All 4 fixation constructs performed in an acceptable manner on testing with simulated partial weight-bearing. Only additional periarticular screws along the QLP increased the fixation strength. Clinical Relevance: Redisplacement of the QLP resulting in an incongruency of the hip joint has been associated with poor long-term outcomes. Within the constraints of this study, periarticular long screws were superior to infrapectineal buttress plates in preventing medial redisplacement of the QLP.

29 April 2009 in Physical Review B
Verified
Journal Article
Closed access
PDF file
MHM. Huefner
M. Huefner
CMC. May
C. May
SKS. Kičin
S. Kičin
KEK. Ensslin
K. Ensslin
TIT. Ihn
T. Ihn
USU. Staufer
U. Staufer
We present measurements on a superconducting single-electron transistor (SET) in which the metallic tip of a low-temperature scanning force microscope is used as a movable gate. We characterize the SET through charge stability diagram measurements and compare them to scanning gate measurements taken in the normal conducting and the superconducting states. The tip-induced potential is found to have a rather complex shape. It consists of a gate voltage-dependent part and a part which is independent of gate voltage. Further scanning gate measurements reveal a dependence of the charging energy and the superconducting gap on the tip position and the voltage applied to it. We observe an unexpected correlation between the magnitude of the superconducting gap and the charging energy. The change in EC can be understood to be due to screening, however the origin of the observed variation in Δ remains to be understood. Simulations of the electrostatic problem are in reasonable agreement with the measured capacitances.

30 March 2011 in Interface Focus
Verified
Journal Article
Closed access
PDF file
Kostas MariasKostas Marias
Kostas Marias
DDD. Dionysiou
D. Dionysiou
Vangelis SakkalisVangelis Sakkalis
Vangelis Sakkalis
NGNorbert Graf
Norbert Graf
RBR. M. Bohle
R. M. Bohle
GSG. Stamatakos
G. Stamatakos
The challenge of modelling cancer presents a major opportunity to improve our ability to reduce mortality from malignant neoplasms, improve treatments and meet the demands associated with the individualization of care needs. This is the central motivation behind the ContraCancrum project. By developing integrated multi-scale cancer models, ContraCancrum is expected to contribute to the advancement of in silico oncology through the optimization of cancer treatment in the patient-individualized context by simulating the response to various therapeutic regimens. The aim of the present paper is to describe a novel paradigm for designing clinically driven multi-scale cancer modelling by bringing together basic science and information technology modules. In addition, the integration of the multi-scale tumour modelling components has led to novel concepts of personalized clinical decision support in the context of predictive oncology, as is also discussed in the paper. Since clinical adaptation is an inelastic prerequisite, a long-term clinical adaptation procedure of the models has been initiated for two tumour types, namely non-small cell lung cancer and glioblastoma multiforme; its current status is briefly summarized.

1 October 2011 in Progress in Biophysics and Molecular Biology
Verified
Journal Article
Closed access
CMChristian P. May
Christian P. May
EKEleni Kolokotroni
Eleni Kolokotroni
GSGeorgios S. Stamatakos
Georgios S. Stamatakos
PBPhilippe Büchler
Philippe Büchler

11 June 2004 in Physical Review C
Verified
Journal Article
Closed access
PDF file
FMFernando Montani
Fernando Montani
CMC. May
C. May
HMH. Müther
H. Müther
Properties of the matter in the inner crust of a neutron star are investigated in a Hartree-Fock plus BCS approximation employing schematic effective forces of the type of the Skyrme forces. Special attention is paid to differences between a homogenous and inhomogeneous description of the matter distribution. For that purpose self-consistent Hartree-Fock calculations are performed in a spherical Wigner-Seitz cell. The results are compared to predictions of corresponding Thomas-Fermi calculations. The influence of the shell structure on the formation of pairing correlations in inhomogeneous matter are discussed.