Billie F. Spencer

Billie F. Spencer

Auto-generated profile, based on publicly available information

Billie F. Spencer

Assistant Professor, Dept. of Civil and Environmental Engineering, Univ. of Connecticut, 261 Glenbrook Rd., Unit 2037, Storrs, CT 06269-2037

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2004 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
BSB. F. Spencer
B. F. Spencer
MRManuel E. Ruiz-Sandoval
Manuel E. Ruiz-Sandoval
NKNarito Kurata
Narito Kurata
‘Smart’ sensors with embedded microprocessors and wireless communication links have the potential to change fundamentally the way civil infrastructure systems are monitored, controlled, and maintained. Indeed, a 2002 National Research Council report noted that the use of networked systems of embedded computers and sensors throughout society could well dwarf all previous milestones in the information revolution. However, a framework does not yet exist that can allow the distributed computing paradigm offered by smart sensors to be employed for structural health monitoring and control systems; current algorithms assume that all data is centrally collected and processed. Such an approach does not scale to systems with densely instrumented arrays of sensors that will be required for the next generation of structural health monitoring and control systems. This paper provides a brief introduction to smart sensing technology and identifies some of the opportunities and associated challenges. Copyright © 2004 John Wiley & Sons, Ltd.

1 January 2007 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
EJErik A. Johnson
Erik A. Johnson
GBGreg A. Baker
Greg A. Baker
BSB. F. Spencer
B. F. Spencer
YFYozo Fujino
Yozo Fujino
Stay cables, such as are used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Transversely attached passive viscous dampers have been implemented in many bridges to dampen such vibration. Several studies have investigated optimal passive linear viscous dampers; however, even the optimal passive device can only add a small amount of damping to the cable when attached a reasonable distance from the cable/deck anchorage. This paper investigates the potential for improved damping using semiactive devices. The equations of motion of the cable/damper system are derived using an assumed modes approach and a control-oriented model is developed. The control-oriented model is shown to be more accurate than other models and facilitates low-order control designs. The effectiveness of passive linear viscous dampers is reviewed. The response of a cable with passive, active, and semiactive dampers is studied. The response with a semiactive damper is found to be dramatic...

9 December 2005 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
YGY. Gao
Y. Gao
BSB. F. Spencer
B. F. Spencer
MRM. Ruiz-Sandoval
M. Ruiz-Sandoval
Monitoring of complex structures to provide real-time safety and reliability information regarding the structure poses significant technical challenges. To detect damage in large civil infrastructure systems, densely distributed sensors are expected to be required. Use of traditional wired sensors is challenging for such applications because of the cost and difficulty in deploying and maintaining a large wiring plant. Using wireless sensor network is also difficult because large amounts of measured data need to be transferred to a central station. The bandwidth and power requirement to transfer these data may easily exceed the limit of the wireless sensor. Recently rapid advances in smart sensor technologies have made damage detection using a dense array of sensors feasible. The essential feature of a smart sensor is the on-board microprocessor, which allows smart sensors to make decisions, perform computation, save data locally, etc. By conducting a portion of the computation at the sensor level, only limited information needs to be transferred back to a central station. However, damage detection algorithms which can take advantage of the distributed computing environment offered by smart sensors are currently limited. In this paper, a new distributed computing strategy for structural health monitoring is proposed that is suitable for implementation on a network of densely distributed smart sensors. In this approach, a hierarchical strategy is proposed in which adjacent smart sensors are grouped together to form sensor communities. A flexibility-based damage detection method is employed to evaluate the condition of the local elements within these communities by utilizing only locally measured information. The damage detection results in these communities are then communicated with the surrounding communities and sent back to a central station. Numerical simulation demonstrates that the proposed approach works well for both single and multiple damage scenarios. Copyright © 2005 John Wiley & Sons, Ltd.

1 March 2006 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
RCRichard E. Christenson
Richard E. Christenson
BSB. F. Spencer
B. F. Spencer
EJErik A. Johnson
Erik A. Johnson
Stay cables, such as are used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Transversely attached passive viscous dampers have been implemented in many bridges to dampen such vibration. However, only minimal damping can be added if the attachment point is close to the bridge deck. For longer bridge cables, the relative attachment point becomes increasingly smaller, and passive damping may become insufficient. A recent analytical study by the authors demonstrated that “smart” semiactive damping can provide increased supplemental damping. This paper experimentally verifies a smart damping control strategy employing H2 ∕linear quadratic Gaussian (LQG) clipped optimal control using only force and displacement measurements at the damper for an inclined flat-sag cable. A shear mode magnetorheological fluid damper is attached to a 12.65 m inclined flat-sag steel cable to reduce cable vibration. Cable response is seen to be substantially reduced by the smart da...

1 June 2006 in Journal of Structural Engineering
Verified
Journal Article
Closed access
RCRichard E. Christenson
Richard E. Christenson
BSB. F. Spencer
B. F. Spencer
EJErik A. Johnson
Erik A. Johnson
KSK. Seto
K. Seto
Coupled building control has been shown to be an effective means of protection for flexible building structures. Numerous researchers have proposed various active, passive, and semiactive coupled building control strategies for both high-rise and low-rise buildings. Actual applications of coupled building control for low-rise buildings and high-rise buildings have been successfully implemented in Japan using passive and active control technology. Much of the research in the literature has focused on specific building pairs. To date, there have been no detailed studies of the effects of the building configuration and connector location on the overall system performance. This paper examines these effects and compares the efficacy of passive and active coupled building control for flexible adjacent buildings.

1 October 2007 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
YGY. Gao
Y. Gao
BSB. F. Spencer
B. F. Spencer
DBD. Bernal
D. Bernal
In recent years, numerous approaches have been proposed for detecting damage in structures, in which the flexibility-based damage locating vector (DLV) method is one of the promising techniques. By computing a set of load vectors from the change of the flexibility matrix before and after damage and then applying them as static forces to the undamaged analytical model for static computation, the DLV method is able to locate damage in structures. The main purpose of this paper is to experimentally verify this method. Following a brief introduction and discussion of the motivation for the flexibility-based method, an overview of the DLV method and construction of the flexibility matrix from limited sensor information is presented. The DLV method is then experimentally verified employing a 5.6 m (18 ft)-long three-dimensional truss structure. To simulate damage in the structure, the original truss member is replaced by one with reduced stiffness. Experimental results show that the DLV method can successfully ...