Djicknack Dione

Djicknack Dione

Auto-generated profile, based on publicly available information

Djicknack Dione

Institute of Applied Nuclear Technology, University Cheikh Anta Diop, 5005, Dakar, SENEGAL

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2024 in American Journal of Modern Physics
Verified
Journal Article
Open access
PDF file
PFPapa Faye
Papa Faye
DDDjicknack Dione
Djicknack Dione
ONOumar Ndiaye
Oumar Ndiaye
MSMoussa Sy
Moussa Sy
NNNogaye Ndiaye
Nogaye Ndiaye
ANAbabacar Ndao
Ababacar Ndao
Applying X-ray fluorescence (XRF), this study investigated the elemental analysis and heavy metal contents in five Senegalese powdered milk samples (V1, L1, H1, G1, and D1). The primary focus was on Aluminum (Al), Calcium (Ca), Potassium (K), Phosphorous (P), and Chlorine (Cl), with special attention given to the compliance of these elements with safety standards. The analysis revealed that Aluminum was either absent or present in minimal quantities across all samples, suggesting that the powdered milk is largely free from this element. Calcium levels were found to be consistently higher than the Acceptable Maximum Level (AML) across all samples, with the H1 sample significantly exceeding the AML by approximately 11.1 times, with a concentration of 27,745.06 ± 310.16 ppm. This indicates a potential risk of excessive calcium intake from this sample. Potassium concentrations varied significantly; while the V1 sample remained within acceptable limits, the G1 sample exhibited potassium levels substantially above the AML, reaching 51,058.15 ± 456.13 ppm, which could pose health concerns if consumed in large quantities. Chlorine concentrations generally met the AML, except for the G1 sample, which slightly surpassed the limit at 3631.04 ± 31.23 ppm. The phosphorus content in the H1 sample was notably high, though further details are needed to fully assess its implications. The study underscores the necessity for continuous monitoring of heavy metal and elemental levels in powdered milk to ensure consumer safety.

3 June 2025 in American Journal of Modern Physics
Verified
Journal Article
Open access
PDF file
NNNogaye Ndiaye
Nogaye Ndiaye
DDDjicknack Dione
Djicknack Dione
ONOumar Ndiaye
Oumar Ndiaye
JFJean Paul Latyr Paul Latyr Faye
Jean Paul Latyr Paul Latyr Faye
ATAlassane TRAORE
Alassane TRAORE
ANAbabacar Ndao
Ababacar Ndao
This study aims to validate the simulation model of the GAMOS/ GEANT4 code for a 6 MV photon beam produced by the Elekta Synergy Agility linear accelerator installed at the International Cancer Center of Dakar (CICD), Senegal. The simulation encompasses all major components of the accelerator head: the target, primary collimator, flattening filter, ionization chamber, and X and Y jaws, using a homogeneous water phantom. The phase space was placed after the jaws, and for each angular distribution model studied: Tsai, Koch–Motz 2BS, and Koch–Motz 2BN, the dose distribution was evaluated. This includes depth dose curves for field sizes of 5 × 5 cm² and 10 × 10 cm² at a source-to-axis distance (SAD) of 100 cm, as well as dose profiles at depths of 5, 10, 15, and 20 cm in the phantom, with a source-to-surface distance (SSD) of 90 cm from the target. The three bremsstrahlung angular distribution models implemented in GAMOS were then compared with experimental measurements. Validation was performed using the gamma index, with an acceptance criterion of 3% for dose difference (DD) and 3 mm for distance to agreement (DTA). For the depth dose curves, a 94% agreement was observed between simulated and experimental data for the 5 × 5 cm² field, and 96% for the 10 × 10 cm² field, regardless of the model. Regarding the dose profiles, the three models: Koch–Motz 2BN, Koch–Motz 2BS, and Tsai, exhibit perfect agreement (100%) with measurements for the 5 × 5 cm² field size at all depths. For the 10 × 10 cm² field, the Koch–Motz 2BN model shows excellent agreement of 100% at 5 cm and 20 cm depths, followed by the Tsai model with 99% at 20 cm. At 10 cm depth, agreement reached 99% for Koch–Motz 2BN and 97% for Tsai. At 15 cm, Koch–Motz 2BN and Tsai achieved 98%, followed by Koch–Motz 2BS with 92%. At 20 cm, Koch–Motz 2BN maintained 100% agreement, followed by Tsai (99%) and Koch–Motz 2BS (94%). This study compares three bremsstrahlung angular distribution models in GAMOS with experimental values, assessing their respective performances in photon beam simulation. These results may guide radiotherapy practitioners in selecting the most appropriate model. In summary, this work contributes to the validation and enhancement of simulation techniques in radiotherapy, thereby improving treatment optimization and patient safety in cancer care.

10 July 2025 in American Journal of Nano Research and Applications
Verified
Journal Article
Open access
PDF file
PFPapa Faye
Papa Faye
DDDjicknack Dione
Djicknack Dione
ANAbabacar Ndao
Ababacar Ndao
Heavy metal contamination in soils poses serious threats to environmental and human health due to metal persistence and toxicity. In Senegal, particularly in the Niakhene region, soil pollution may result from agricultural practices, atmospheric deposition, and past land use. This study aims to determine the concentrations of heavy metals: Nickel (Ni), Arsenic (As), Zinc (Zn), Cesium (Cs), Palladium (Pd), and Tin (Sn) in agricultural soils and to assess their potential environmental and health risks. A total of 47 soil samples were collected at two depths (0–20 cm and 20–40 cm) and analyzed using energy-dispersive X-ray fluorescence (ED-XRF) spectroscopy, a non-destructive and accurate technique. The analysis revealed varying concentrations of heavy metals, with Zn ranging from 0.00 to 29.49 mg/kg, Ni from 20.02 to 47.30 mg/kg, and Arsenic (As) from 0.00 to 5.67 mg/kg. The study found that Cd, Cu, Pb, and Hg were not detectable in the samples. Comparative analysis with EU threshold limit values (TLVs) indicated that concentrations of most metals were within safe limits, although some samples approached the maximum contaminant levels (MCLs) for Nickel and Arsenic. The findings highlight the need for ongoing monitoring and potential remediation to manage soil contamination and protect environmental and human health. These findings highlight the importance of continuous soil monitoring in the region and support the implementation of appropriate soil management and pollution mitigation strategies to safeguard both environmental quality and public health.

29 July 2024 in American Journal of Modern Physics
Verified
Journal Article
Open access
PDF file
DDDjicknack Dione
Djicknack Dione
PFPapa Faye
Papa Faye
ONOumar Ndiaye
Oumar Ndiaye
NNNogaye Ndiaye
Nogaye Ndiaye
MSMoussa Sy
Moussa Sy
ANAbabacar Ndao
Ababacar Ndao
An essential micronutrient for plant growth and development, iron (Fe) affects a number of physiological processes, including respiration and photosynthesis. This study compare the amounts of iron in agricultural zones and reference zones, describe the geographic distribution of iron, and assess its accessibility to cultures. The aim is to assess the deficiencies and excess soil disturbance in the Niankhène agricultural site while maintaining a stable site. Soil samples were taken at 0–20 cm and 20–40 cm depths from 47 agricultural stations and three reference points using X-ray fluorescence (XRF) spectroscopy. Significant variation in Fe concentrations was found by the research, with an average of roughly 3310.95 ppm and moderate variation between samples. An analysis conducted in comparison with reference locations revealed a widespread lack of Fe in the research area, with 85.71% of samples displaying depletion and only 14.29% displaying accumulation of Fe. This discrepancy emphasizes the necessity of focused soil management techniques to raise Niankhene's agricultural output. The results highlight how crucial it is to use site-specific soil management strategies in order to overcome Fe deficits and raise crop yields. This research highlights the possibility for establishing targeted fertilization and corrective procedures to maximize Fe availability by utilizing XRF technology for reliable soil nutrient monitoring. The study's findings offer insightful information for enhancing fertilization techniques and improving soil management techniques, which will support sustainable farming methods and increased crop yield in the area.

26 November 2025 in Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi
Verified
Journal Article
Closed access
NNNogaye Ndiaye
Nogaye Ndiaye
ONOumar Ndiaye
Oumar Ndiaye
DDDjicknack Dione
Djicknack Dione
JFJean Paul Latyr Paul Latyr Faye
Jean Paul Latyr Paul Latyr Faye
ATAlassane TRAORE
Alassane TRAORE
ANAbabacar Sadikhe Ndao
Ababacar Sadikhe Ndao
The Monte Carlo code GAMOS 6.2.0, based on version 10.06.p02 of GEANT4, was employed to model the Elekta Synergy Agility linear accelerator (Linac). The Linac’s irradiation head was simulated by modeling the target, primary collimator, flattening filter, ionization chamber, and the X and Y jaws. Phase spaces were then simulated after the X and Y jaws for each variance reduction technique: UBS (Uniform Bremsstrahlung Splitting), DBS (Directional Bremsstrahlung Splitting), and EWBS (Equal Weight Bremsstrahlung Splitting), with field sizes of 5 × 5 cm² and 10 × 10 cm². The dose distribution was subsequently calculated for each variance reduction technique in a homogeneous water phantom at depths of 5 cm, 10 cm, 15 cm, and 20 cm. The results obtained were compared with experimental data using the gamma index, with an acceptance criterion of 3% for dose difference (DD) and 3 mm for distance-to-agreement (DTA). For a 5 × 5 cm² field size, a 94% agreement was obtained between the simulated and experimental data for depth-dose curves using the three techniques: EWBS, DBS, and UBS. Regarding dose profiles, the EWBS, DBS, and UBS techniques showed excellent agreement of 100% with the experimental data for a 5 × 5 cm² field at a depth of 5 cm. At 10 cm depth, the EWBS technique achieved 100% agreement, followed by DBS at 98%. At 15 cm depth, EWBS and DBS also showed 100% agreement, while UBS achieved 97%. Finally, at 20 cm depth, EWBS presented 100% agreement, followed by DBS and UBS at 99%. For a 10 × 10 cm² field size, a 96% agreement was achieved between the simulated and experimental data for depth-dose curves with the three techniques: EWBS, DBS, and UBS. Regarding dose profiles, the EWBS technique showed 99% agreement, followed by DBS at 98% at a depth of 5 cm. At a depth of 10 cm, EWBS showed 99% agreement, followed by UBS at 98%. At 15 cm depth, EWBS reached 100% agreement, followed by DBS at 99%. Finally, at 20 cm depth, EWBS maintained 100% agreement, followed by DBS at 97%. The results of this study are significant for medical physics applications, as they can guide radiotherapy practitioners in selecting the most appropriate technique for their simulations. Thus, this paper contributes to the advancement of simulation method development and validation, which can ultimately lead to safer and more effective treatments for cancer patients.