Lukasz Antoni Sterczewski

Lukasz Antoni Sterczewski

Auto-generated profile, based on publicly available information

Lukasz Antoni Sterczewski

Wroclaw University of Science and Technology

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2019 in Optics Express
Verified
Journal Article
Closed access
LSLukasz A. Sterczewski
Lukasz A. Sterczewski
JWJonas Westberg
Jonas Westberg
GWGerard Wysocki
Gerard Wysocki
Dual-comb spectroscopy is a rapidly developing spectroscopic technique that does not require any opto-mechanical moving parts and enables broadband and high-resolution measurements with microsecond time resolution. However, for high sensitivity measurements and extended averaging times, high mutual coherence of the comb-sources is essential. To date, most dual-comb systems employ coherent averaging schemes that require additional electro-optical components, which increase system complexity and cost. More recently, computational phase correction approaches that enables coherent averaging of spectra generated by free-running systems have gained increasing interest. Here, we propose such an all-computational solution that is compatible with real-time data acquisition architectures for free-running systems. The efficacy of our coherent averaging algorithm is demonstrated using dual-comb spectrometers based on quantum cascade lasers, interband cascade lasers, mode-locked lasers, and optically-pumped microresonators.

20 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MBMahmood Bagheri
Mahmood Bagheri
CFClifford Frez
Clifford Frez
LSLukasz A. Sterczewski
Lukasz A. Sterczewski
IGIvan Gruidin
Ivan Gruidin
MFMathieu Fradet
Mathieu Fradet
JMJerry R. Meyer
Jerry R. Meyer
Since their inception, optical frequency combs have transformed a broad range of technical and scientific disciplines, spanning time keeping to navigation. Recently, dual comb spectroscopy has emerged as an attractive alternative to traditional Fourier transform spectroscopy, since it offers higher measurement sensitivity in a fraction of the time. Midwave infrared (mid-IR) frequency combs are especially promising as an effective means for probing the strong fundamental absorption lines of numerous chemical and biological agents. Mid-IR combs have been realized via frequency down-conversion of a near-IR comb, by optical pumping of a micro-resonator, and beyond 7 μm by four-wave mixing in a quantum cascade laser. In this work, we demonstrate an electrically-driven frequency comb source that spans more than 1 THz of bandwidth centered near 3.6 μm. This is achieved by passively mode-locking an interband cascade laser (ICL) with gain and saturable absorber sections monolithically integrated on the same chip. The new source will significantly enhance the capabilities of mid-IR multi-heterodyne frequency comb spectroscopy systems.

31 May 2019 in Optica
Verified
Journal Article
Closed access
PDF file
LSLukasz A. Sterczewski
Lukasz A. Sterczewski
JWJonas Westberg
Jonas Westberg
YYYang Yang
Yang Yang
DBDavid Burghoff
David Burghoff
JRJohn Reno
John Reno
GWGerard Wysocki
Gerard Wysocki
Hyperspectral imaging is a spectroscopic imaging technique that allows for the creation of images with pixels containing information from multiple spectral bands. At terahertz wavelengths, it has emerged as a prominent tool for a number of applications, ranging from nonionizing cancer diagnosis and pharmaceutical characterization to nondestructive artifact testing. Contemporary terahertz imaging systems typically rely on nonlinear optical downconversion of a fiber-based near-infrared femtosecond laser, requiring complex optical systems. Here, we demonstrate hyperspectral imaging with chip-scale frequency combs based on terahertz quantum cascade lasers. The dual combs are free-running and emit coherent terahertz radiation that covers a bandwidth of 220 GHz at 3.4 THz with ∼10  μW per line. The combination of the fast acquisition rate of dual-comb spectroscopy with the monolithic design, scalability, and chip-scale size of the combs is highly appealing for future imaging applications in biomedicine and the pharmaceutical industry.

15 April 2019 in Optics Letters
Verified
Journal Article
Open access
PDF file
LSLukasz A. Sterczewski
Lukasz A. Sterczewski
JWJonas Westberg
Jonas Westberg
MBMahmood Bagheri
Mahmood Bagheri
CFClifford Frez
Clifford Frez
IVIgor Vurgaftman
Igor Vurgaftman
GWGerard Wysocki
Gerard Wysocki
Two semiconductor optical frequency combs, consuming less than 1 W of electrical power, are used to demonstrate high-sensitivity mid-infrared dual-comb spectroscopy in the important 3–4 μm spectral region. The devices are 4 mm long by 4 μm wide, and each emits 8 mW of average optical power. The spectroscopic sensing performance is demonstrated by measurements of methane and hydrogen chloride with optical multi-pass cell sensitivity enhancement. The system provides a spectral coverage of 33  cm−1 (1 THz), 0.32  cm−1 (9.7 GHz) frequency sampling interval, and peak signal-to-noise ratio of ∼100 at 100 μs integration time. The monolithic design, low drive power, and direct generation of mid-infrared radiation are highly attractive for portable broadband spectroscopic instrumentation in future terrestrial and space applications.

1 November 2019 in APL Photonics
Verified
Journal Article
Open access
PDF file
ŁSŁukasz A. Sterczewski
Łukasz A. Sterczewski
APAleksandra Przewloka
Aleksandra Przewloka
WKWawrzyniec Kaszub
Wawrzyniec Kaszub
JSJaroslaw Sotor
Jaroslaw Sotor
Dual-comb spectroscopy has emerged as an indispensable analytical technique in applications that require high resolution and broadband coverage within short acquisition times. Its experimental realization, however, remains hampered by intricate experimental setups with large power consumption. Here, we demonstrate an ultrasimple free-running dual-comb spectrometer realized in a single all-fiber cavity suitable for the most demanding Doppler-limited measurements. Our dual-comb laser utilizes just a few basic fiber components, allows us to tailor the repetition rate difference, and requires only 350 mW of electrical power for sustained operation over a dozen of hours. As a demonstration, we measure low-pressure hydrogen cyanide within 1.7 THz bandwidth and obtain better than 1% transmittance precision over a terahertz in 200 ms enabled by an all-computational phase retrieval and correction algorithm. The combination of the setup simplicity, comb tooth resolution, and high spectroscopic precision paves the way for proliferation of frequency comb spectroscopy on a larger scale.

3 April 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
JWJonas Westberg
Jonas Westberg
LSL. A. Sterczewski
L. A. Sterczewski
GWGerard Wysocki
Gerard Wysocki
Fabry-Pérot (FP) quantum cascade lasers (QCLs) provide purely electronically controlled monolithic sources for broadband mid-infrared (mid-IR) multiheterodyne spectroscopy (MHS), which benefits from the large gain bandwidth of the QCLs without sacrificing the narrowband properties commonly associated with the single mode distributed feedback variant. We demonstrate a FP-QCL based multiheterodyne spectrometer with a short-term noise-equivalent absorption of ∼3 × 10−4/ H z , a mid-IR spectral coverage of 25 cm−1, and very short acquisition time (10 μs) capability. The broadband potential is demonstrated by measuring the absorption spectra of ammonia and isobutane under atmospheric pressure conditions. The stability of the system is enhanced by a two-stage active frequency inter-locking procedure, where the two QCLs are pre-locked with a slow feedback loop based on an analog frequency discriminator, followed by a high bandwidth optical phase-locked loop. The locking system provides a relative frequency stability in the sub kHz range over seconds of integration time. The strength of the technique lies in the ability to acquire spectral information from all optical modes simultaneously and individually, which bodes for a versatile and cost effective spectrometer for mid-IR chemical gas sensing.