Gerrit Hermann

Gerrit Hermann

Auto-generated profile, based on publicly available information

Gerrit Hermann

Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Strasse 38, 1090 Vienna, Austria

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2018 in The Analyst
Verified
Journal Article
Open access
PDF file
MSMichaela Schwaiger
Michaela Schwaiger
HSHarald Schoeny
Harald Schoeny
YAYasin El Abiead
Yasin El Abiead
GHGerrit Hermann
Gerrit Hermann
Evelyn RamplerEvelyn Rampler
Evelyn Rampler
GKGunda Koellensperger
Gunda Koellensperger
A novel integrated metabolomics/lipidomics workflow is introduced enabling high coverage of polar metabolites and non-polar lipids within one analytical run. Dual HILIC and RP chromatography were combined to high-resolution mass spectrometry. As a major advantage, only one data file per sample was obtained by fully automated simultaneous analysis of two extracts per sample. Hence, the unprecedented high coverage without compromise on analytical throughput was not only obtained by the orthogonality of the chromatographic separations, but also by the implementation of dedicated sample preparation procedures resulting in optimum extraction efficiency for both sub-omes. Thus, the method addressed completely hydrophilic sugars and organic acids next to water-insoluble triglycerides. As for the timing of the dual chromatography setup, HILIC and RP separation were performed consecutively. However, re-equilibration of the HILIC column during elution of RP compounds and vice versa reduced the overall analysis time by one third to 32 min. Application to the Standard Reference Material SRM 1950 – Metabolites in Frozen Human Plasma resulted in >100 metabolite and >380 lipid identifications based on accurate mass implementing fast polarity switching and acquiring data dependent MS2 spectra with the use of automated exclusion lists. Targeted quantification based on external calibrations and 13C labeled yeast internal standards was successfully accomplished for 59 metabolites. Moreover, the potential for lipid quantification was shown integrating non-endogenous lipids as internal standards. In human plasma, concentrations ranging over 4 orders of magnitude (low nM to high μM) were assessed.

24 February 2016 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
GHGerrit Hermann
Gerrit Hermann
LMLaura Hyrup Møller
Laura Hyrup Møller
BGBente Gammelgaard
Bente Gammelgaard
JHJonas Hohlweg
Jonas Hohlweg
DMDiethard Mattanovich
Diethard Mattanovich
GKGunda Koellensperger
Gunda Koellensperger
Production of 34S enriched amino acids using yeast.

5 November 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
HSHarald Schoeny
Harald Schoeny
Evelyn RamplerEvelyn Rampler
Evelyn Rampler
YAYasin El Abiead
Yasin El Abiead
FHFelina Hildebrand
Felina Hildebrand
OZOlivia Zach
Olivia Zach
GKGunda Koellensperger
Gunda Koellensperger
We propose a fully automated novel workflow for lipidomics based on flow injection-followed by liquid chromatography high resolution mass spectrometry (FI/LC-HRMS). The workflow combined in-depth characterization of the lipidome achieved via reversed phase LC-HRMS with absolute quantification as obtained by a high number of lipid species-specific- and/or retention time (RT) matched/class-specific calibrants. The lipidome of 13 C labelled yeast (LILY) provided a cost efficient, large panel of internal standards covering triacylglycerols (TG), steryl esters (SE), free fatty acids (FA), diacylglycerols (DG), sterols (ST), ceramides (Cer), hexosyl ceramides (HexCer), phosphatidylglycerols (PG), phosphatidylethanolamines (PE), phosphatidic acids (PA), cardiolipins (CL), phosphatidylinositols (PI), phosphatidylserines (PS), phosphatidylcholines (PC), lysophosphatidylcholines (LPC) and lysophosphatidylethanolamines (LPE). In order to exploit the full potential of isotopically enriched biomass, LILY was absolutely quantified on demand via reversed isotope dilution analysis using FI-HRMS. Subsequent LC-HRMS analysis integrated different calibration strategies including lipid species-specific standards for >90 lipids. Extensive measures on quality control allowed to rank the calibration strategies and to automatically selected the calibration strategy of highest metrological order for the respective lipid species. Overall, the workflow enabled a streamlined analysis pipeline (identification and quantification in separate analytical runs) and provided validation tools together with absolute concentration values for >350 lipids in human plasma on a species level with an analytical run-time of less than 25 min per sample. TOC:

6 October 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
Evelyn RamplerEvelyn Rampler
Evelyn Rampler
GHGerrit Hermann
Gerrit Hermann
LGLindi Grabmann
Lindi Grabmann
YAYasin El Abiead
Yasin El Abiead
HSHarald Schoeny
Harald Schoeny
GKGunda Koellensperger
Gunda Koellensperger
Non-targeted analysis by high-resolution mass spectrometry (HRMS) is the essential discovery tool in metabolomics. Up to date, standardization and validation remain a challenge. Community wide accepted, cost-effective benchmark materials are lacking. In this work, we propose yeast ( Pichia pastoris ) extracts, derived from fully controlled fermentations for this purpose. We established an open-source metabolite library of > 200 metabolites, reproducibly recovered in ethanolic extracts by orthogonal LCHRMS methods, different fermentations (over three years) and different laboratories. More specifically, compound identification was based on accurate mass, matching retention times, and MS/MS spectra as compared to authentic standards and internal databases. The library includes metabolites from the classes of 1) organic acids and derivatives (2) nucleosides, nucleotides and analogues, (3) lipids and lipid-like molecules, (4) organic oxygen compounds, (5) organoheterocyclic compounds, (6) organic nitrogen compounds and (7) benzoids at expected concentrations ranges of sub-nM to µM. As yeast is a eukaryotic organism, key regulatory elements are highly conserved between yeast and all annotated metabolites were also reported in the Human metabolome data base (HMDB). A large fraction of metabolites was found to be stable for several years when stored at −80°C. Thus, the yeast benchmark material enabled not only to test for the chemical space and coverage upon method implementation and developments, but enabled in-house routines for instrumental performance tests. Finally, the benchmark material opens new avenues for batch to batch corrections in large scale non-targeted metabolomics studies.