Jie Hua

Jie Hua

Auto-generated profile, based on publicly available information

Jie Hua

Department of Gastroenterology, The First Affiliated Hospital of Nanjing Medical University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2020 in World Journal of Gastroenterology
Verified
Journal Article
Open access
MSMeng-Xue Sun
Meng-Xue Sun
XHXiao-Pu He
Xiao-Pu He
PHPei-Yun Huang
Pei-Yun Huang
QQQi Qi
Qi Qi
WSWei-Hao Sun
Wei-Hao Sun
JHJie Hua
Jie Hua
Acetyl-11-keto-β-boswellic acid inhibits proliferation and induces apoptosis of gastric cancer cells through the phosphatase and tensin homolog /Akt/ cyclooxygenase-2 signaling pathway

24 August 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
KWKaini Wang
Kaini Wang
SZShuaishuai Zhuang
Shuaishuai Zhuang
JMJuzheng Miao
Juzheng Miao
YCYang Chen
Yang Chen
JHJie Hua
Jie Hua
SLShuo Li
Shuo Li
The automatic and dependable identification of colonic disease subtypes by colonoscopy is crucial. Once successful, it will facilitate clinically more in-depth disease staging analysis and the formulation of more tailored treatment plans. However, inter-class confusion and brightness imbalance are major obstacles to colon disease subtyping. Notably, the Fourier-based image spectrum, with its distinctive frequency features and brightness insensitivity, offers a potential solution. To effectively leverage its advantages to address the existing challenges, this article proposes a framework capable of thorough learning in the frequency domain based on four core designs: the position consistency module, the high-frequency self-supervised module, the complex number arithmetic model, and the feature anti-aliasing module. The position consistency module enables the generation of spectra that preserve local and positional information while compressing the spectral data range to improve training stability. Through band masking and supervision, the high-frequency autoencoder module guides the network to learn useful frequency features selectively. The proposed complex number arithmetic model allows direct spectral training while avoiding the loss of phase information caused by current general-purpose real-valued operations. The feature anti-aliasing module embeds filters in the model to prevent spectral aliasing caused by down-sampling and improve performance. Experiments are performed on the collected five-class dataset, which contains 4591 colorectal endoscopic images. The outcomes show that our proposed method produces state-of-the-art results with an accuracy rate of 89.82%. The source code is released at https://github.com/soleilssss/AFACNet .

14 June 2022 in World Journal of Gastroenterology
Verified
Journal Article
Open access
GLGao-Shuang Liu
Gao-Shuang Liu
PHPei-Yun Huang
Pei-Yun Huang
MWMin-Li Wen
Min-Li Wen
SZShuai-Shuai Zhuang
Shuai-Shuai Zhuang
JHJie Hua
Jie Hua
XHXiao-Pu He
Xiao-Pu He
Application of endoscopic ultrasonography for detecting esophageal lesions based on convolutional neural network

1 April 2022 in Journal of Digestive Diseases
Verified
Journal Article
Closed access
HCHan Chen
Han Chen
XZXiao Ying Zhou
Xiao Ying Zhou
SLShuo Li
Shuo Li
LJLiuqin Jiang
Liuqin Jiang
JHJie Hua
Jie Hua
GZGuo Xin Zhang
Guo Xin Zhang

12 March 2026 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
XWXiao Wang
Xiao Wang
LPLiangpeng Pu
Liangpeng Pu
SYShanshan Yan
Shanshan Yan
SZShuaishuai Zhuang
Shuaishuai Zhuang
JHJie Hua
Jie Hua
XHXiaopu He
Xiaopu He
Background: Gastric subepithelial lesions (SELs) are typically covered by intact mucosa, which challenges the determination of their layer of origin under conventional endoscopy. Endoscopic ultrasonography (EUS) is indispensable for diagnosing SELs. However, EUS operation and interpretation are more challenging than standard endoscopy and are subject to inter-observer variability. This study aimed to develop a novel AI system based on the MedMamba architecture to assist clinicians in identifying the layer of origin of gastric SELs. Methods: We retrospectively collected data from patients who underwent EUS at the First Affiliated Hospital of Nanjing Medical University between May 1, 2016 and May 1, 2023. The dataset comprised 1,855 images from 320 patients. Images were split into training, validation, and test sets at an 8:1:1 ratio at the patient level to prevent data leakage. A structured State space sequence model (MedMamba) was trained and the performance was compared against endoscopists. Results: The proposed MedMamba model achieved an overall accuracy of 92.04% (95%CI: 90.33–93.75%), with 94.83% (95%CI: 93.22–96.44%) specificity and 81.11% (95%CI: 75.19–87.03%) sensitivity in the five-category classification. It achieved high sensitivity and accuracy, outperforming other AI models. Conclusion: The MedMamba-based AI system demonstrated superior performance in discriminating the layer of origin of SELs compared with other AI models, indicating its potential utility in reducing diagnostic variability and enhancing clinical diagnostic workflows.