Prithwiraj Purkait

Prithwiraj Purkait

Auto-generated profile, based on publicly available information

Prithwiraj Purkait

Jadavpur University

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2004 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
TSTapan Saha
Tapan Saha
PPP. Purkait
P. Purkait
Moisture and ageing strongly influence the dielectric properties of oil/paper insulation system of power transformer. Moisture measurement in oil sample generally gives inconclusive information since oil/paper moisture equilibrium is temperature dependent and takes a long time to be in equilibrium. Direct moisture measurement of paper sample is not practicable for in-service transformers. The measurement and evaluation of the "dielectric response" and conductivity is one possible way of diagnosing a transformer insulation condition. In a recent research project, polarization and depolarization current measurement has been used for assessing the condition of oil/paper insulation. The polarization and depolarization current (PDC) analysis is a nondestructive dielectric testing method for determining the conductivity and moisture content of insulation materials in a transformer. On the basis of this analysis it is possible to take further actions like oil-refurbishment, drying or replacement of the winding of the transformer. This paper presents a description of the PDC technique with the physical and mathematical background and some results of PDC measurements on several transformers. Analyses and interpretation of the field test data are also presented in this paper.

14 February 2005 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TSTapan Saha
Tapan Saha
PPP. Purkait
P. Purkait
FMF. Muller
F. Muller
Preventive diagnosis and maintenance of transformers have become more and more popular in recent times in order to improve the reliability of electric power systems. Dielectric testing techniques such as return voltage measurement (RVM) and polarization-depolarization current (PDC) measurement are being investigated as potential tools for condition assessment of transformer insulation. A better understanding and analysis of the dielectric test results are only possible with a clear understanding of the physical behavior of the insulation system in response to moisture and aging. A circuit model, which describes the dielectric behavior of the transformer's main insulation system, has been parameterized in this paper. The values of the parameters of the model have been identified from the dielectric tests. A correlation has been developed between the physical condition of the insulation and the equivalent model parameters that enable a clear and transparent interpretation of the dielectric test results.

26 December 2007 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TSTapan Saha
Tapan Saha
PPPrithwiraj Purkait
Prithwiraj Purkait
Dielectric testing techniques, in both time and frequency domains, are currently widely used by power utilities for assessment of the condition of transformer oil-paper insulation systems. However, it has been reported that results of these tests are highly influenced by the operating temperature during measurements. The distribution, migration and equilibrium of moisture between oil and paper in a complicated insulation system is highly temperature dependent. It requires adequate experience and proper understanding to interpret the dielectric response results in the presence of temperature variations and thermal instability. Proper analysis of the dielectric test result is only possible with an understanding of the physical behavior of the insulation system in response to temperature. A circuit model, which describes the dielectric behavior of the transformers main insulation system, has been investigated in this paper. The values of the parameters of the model have been identified from the dielectric tests. A correlation has been observed between the operating temperature and the equivalent model parameters that can be used as additional information for better interpretation of the dielectric test results. This paper thus reports a detailed study on the effects of temperature on dielectric measurements of a transformer under controlled laboratory conditions. Some results of practical on-site testing are also presented to demonstrate the possibility of errors that may be introduced in dielectric test results analysis unless temperature effects are taken into consideration.

3 April 2008 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
TSTapan Saha
Tapan Saha
PPP. Purkait
P. Purkait
Properties of oil and paper in a transformer degrade primarily due to thermal ageing and moisture ingress. Dielectric diagnostic tests, such as Recovery Voltage (RV), and Polarizations and Depolarization Current (PDC) measurement are currently being explored as potential tools for insulation condition assessment. A modern chemical analysis tool for paper molecular weight (MW) measurement, Gel Permeation Chromatography (GPC) or the more accurately described Size Exclusion Chromatography (SEC) promises to be useful in assessing ageing condition. However, the issue of separately assessing the impacts of ageing and moisture on oil and paper has been a key issue for many years. In the current research project, a series of experiments have been performed under controlled laboratory conditions with preset moisture content, and at controlled high temperature ageing. Whereas RV and PDC measurement results were found to be more sensitive to the moisture content of the oil and paper insulation, the MW distribution measurement by SEC provided a trend of insulation thermal ageing. This paper first provides a brief description of RVM, PDC and SEC procedures followed by a description of the experimental techniques adopted. Results are then analysed with the view of separately understanding the impacts of thermal ageing and moisture on the condition of oil and paper insulation in a transformer.

28 June 2004 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TSTapan Saha
Tapan Saha
PPP. Purkait
P. Purkait
The need for economic, reliable, and effective delivery of electric power has lead to the search for fast, efficient, and effective methods for diagnosing the insulation of high-voltage (HV) equipment in the power industries. The recent dielectric techniques that have been carefully considered by major industries for transformer insulation condition assessment are the recovery voltage method (RVM) and the polarization and depolarization current (PDC) measurement. However, due to the complexity of the transformer insulation structure and various degradation mechanisms under multiple stresses, insulation condition assessment is usually performed by experts with special knowledge and experience. In this paper, an expert system (ES) is developed, which imitates the performance of a human expert, to make the complicated insulation condition assessment procedure accessible to plant maintenance engineers. The structure of the ES is described in detail including knowledge base, inference engine, and human-computer interface. Examples of the application of the ES are also presented to confirm that the system can provide accurate insulation diagnosis.

1 June 2009 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
PBP.S. Bhowmik
P.S. Bhowmik
PPP. Purkait
P. Purkait
KBK. Bhattacharya
K. Bhattacharya