2 December 2024 in PRX Quantum
Cavity quantum electrodynamics offers the possibility of observing and controlling the motion of a few or individual atoms, enabling the realization of various quantum technological tasks such as quantum enhanced metrology or quantum simulation of strongly correlated matter. A core limitation of these experiments lies in the mode structure of the cavity field, which is hard coded in the shape and geometry of the mirrors. As a result, most applications of cavity QED trade spatial resolution for enhanced sensitivity. Here, we propose and demonstrate a cavity-microscope device capable of controlling in space and time the coupling between atoms and light in a single-mode high-finesse cavity, reaching a spatial resolution an order of magnitude lower than the cavity-mode waist. This is achieved through local Floquet engineering of the atomic level structure, imprinting a corresponding atom-field coupling. We illustrate this capability by engineering micrometer-scale coupling, using cavity-assisted atomic measurements and optimization. Our system forms an optical device with a single optical axis, has the same footprint and complexity as a standard Fabry-Perot cavity or confocal lens pair, and can be used for any atomic species. This technique opens a wide range of perspectives, from ultrafast cavity-enhanced midcircuit readout to the quantum simulation of fully connected models of quantum matter such as the Sachdev-Ye-Kitaev model. Published by the American Physical Society 2024
7 August 2025 in Measurement Science and Technology
A custom-developed magneto-mechanical resonator (MMR) for wireless pressure measurement is investigated for potential applications in process engineering. The MMR sensor utilises changes in the resonance frequency caused by pressure on a flexible 3D printed membrane. The thickness of the printed membrane plays a crucial role in determining the performance and sensitivity of MMRs and can be tailored to meet the requirements of specific applications. The study includes static and dynamic measurements to determine the pressure sensitivity and temporal resolution of the sensor. The results show a minimum sensitivity of and are in agreement with theoretical calculations and measurements. The maximum sensor readout frequency is 2 Hz in this study. Additionally, the temperature dependence of the sensor is investigated, revealing a significant dependence of the resonance frequency on temperature. The developed MMR offers a promising and versatile method for precise pressure measurements in process engineering environments.
22 August 2024 in Advanced Intelligent Systems
Magnetic field generators are a key component of Magnetic Particle Imaging (MPI) systems, and their power consumption is a major obstacle on the path to human‐sized scanners. Despite their importance, a focused discussion of these generators is rare, and a comprehensive description of the design process is currently lacking. This work presents a methodology for the design and optimization of selection field generators operating with soft magnetic materials outside the linear regime in the context of MPI. Key elements are a mathematical model of magnetic field generators, a formalism for defining field sequences, and a relationship between power consumption and field sequence. These are used to define the design space of a field generator given its system requirements and constraints. The design process is then formulated as an optimization problem. Subsequently, this methodology is then utilized to design a new magnetic field generator specifically for cerebral imaging studies. The optimization result outperforms our existing MPI field generator in terms of power consumption and field of view size, providing a proof‐of‐concept for the entire methodology. As the approach is very general, it can be extended beyond the MPI context to other areas such as magnetic manipulation of medical devices and micro‐robotics.
25 August 2025 in IEEE Sensors Journal
The precise derivation of physical quantities like temperature or pressure at arbitrary locations is useful in numerous contexts, e.g. medical procedures or industrial process engineering. The novel sensor technology of magneto-mechanical resonators (MMR), based on the interaction of a rotor and stator permanent magnet, allows for the combined tracking of the sensor position and orientation while simultaneously sensing an external measurand. Thereby, the quantity is coupled to the torsional oscillation frequency, e.g. by varying the magnet distance. In this paper, we analyze the (deflection angle-independent) natural frequency dependency of MMR sensors on the rotor-stator distance, and evaluate the performance of theoretical models. The three presented sensors incorporate magnets of spherical and/or cylindrical geometry and can be operated at adjustable frequencies within the range of 61.9−307.3 Hz. Our proposed method to obtain the natural frequency demonstrates notable robustness to variations in the initial deflection amplitudes and quality factors resulting in statistical errors on the mean smaller than 0.05%. We find that the distance-frequency relationship is well described by an adapted dipole model accounting for material and manufacturing uncertainties. Their combined effect can be compensated by an adjustment of a single parameter which drives the median model deviation generally below 0.2%. Our depicted methods and results are important for the design and calibration process of new sensor types utilizing the MMR technique.
12 November 2025 in IEEE Sensors Journal
Accurate and efficient volumetric magnetic field measurements are essential for a wide range of applications. Conventional methods are often limited in terms of measurement speed and applicability, or suffer from scaling problems at larger volumes. This work presents a proof-of-concept field camera designed to measure magnetic fields within a spherical volume at a frame rate of 10 Hz. The camera features an array of 3D Hall magnetometers positioned according to a spherical t-design, allowing simultaneous magnetic field data acquisition from the surface of the sphere. The approach enables the efficient representation of all three components of the magnetic field inside the sphere using a sixth-degree polynomial, significantly reducing measurement time compared to sequential methods. This work details the design, calibration, and measurement methods of the field camera. To evaluate its performance, we compare it to a sequential single-sensor measurement by examining a magnetic gradient field. The obtained measurement uncertainties of approx. 1% demonstrate the feasibility of the approach and its potential applicability to a variety of future applications.
17 November 2024 in Advanced Intelligent Systems