The system of partial differential equations which forms the basic semiconductor equations together with appropriate boundary conditions cannot be solved explicitly in general. Therefore, the solution must be calculated by means of numerical approaches. Finite Element Analysis (FEA) is a computer simulation technique used in engineering analysis with numerical technique called finite element method (FEM). The aim of this paper is to show the progress obtained in understanding the relationship between finite elements with the basic semiconductor equations. An implementation of FEM also includes Gummel's and Newton-Raphson algorithms for both Poisson and current continuity equations. Results for the numerical analysis are shown for Gate Turn-Off (GTO) thyristor based on silicon carbide (SiC) materials.
The increasing in wind turbines (WTs) generation system required grid utilities to extend its ability not only to provide active power but also having reactive power capability to fulfill transmission system requirements. The reactive power capability is subject to several limitations which change with the operating point. In doubly fed induction generator (DFIG) based WT, a special attention around synchronous operating point is needed since the limitation of maximum junction temperature of switching devices cause a reduction on maximum permissible output current at the rotor side. This paper investigates the reactive power capability of the DFIG with three-level neutral point clamped (NPC) voltage source converter (VSC) and provides a comparison with two-level VSC. The thermal behavior of the converters using semiconductor losses and thermal model are illustrated. Simulation results show that three-level NPC converter increased the maximum permissible rotor current as well as the reactive power capability of the DFIG.
The output generated by photovoltaic arrays is influenced mainly by the irradiance, which has non-uniform distribution in a day. This has resulted in the current-limiting nature and nonlinear output characteristics, and conventional protection devices cannot detect and clean faults appropriately. This paper proposes a low-cost model for a multi-scale dual-stage photovoltaic fault detection, classification, and monitoring technique developed through MATLAB/Simulink. The main contribution of this paper is that it can detect multiple common faults, be applied on multi-scale photovoltaic arrays regardless of environmental conditions, and be beneficial for photovoltaic system maintenance work. The experimental results show that the developed algorithm using supervised learning algorithms mutual with k-fold cross-validation has produced good performances in identifying six common faults of photovoltaic arrays, achieved 100% accuracy in fault detection, and achieved good accuracy in fault classification. Challenges and suggestions for future research direction are also suggested in this paper. Overall, this study shall provide researchers and policymakers with a valuable reference for developing photovoltaic system fault detection and monitoring techniques for better feasibility, safety, and energy sustainability.
11 December 2025 in International Journal of Energy and Environmental Science
The growing energy requirements of modern urban areas, particularly for public infrastructure such as street lighting and signaling systems, have intensified the need for innovative and sustainable renewable energy solutions. Among emerging concepts, vehicle-induced turbulence (VIT) has gained attention as a potential yet underexplored source of supplemental energy in densely populated urban environments. This study investigates the feasibility of harvesting VIT using vertical axis wind turbines (VAWTs) strategically integrated into roadside infrastructure to capture the airflow generated by moving vehicles. Unlike conventional power systems that rely heavily on grid electricity or fossil fuels, the proposed approach aims to provide a sustainable and cost-effective solution that reduces both operational expenses and environmental impacts. Computational Fluid Dynamics (CFD) simulations were conducted using ANSYS to analyze airflow behavior, pressure distribution, and aerodynamic characteristics around the turbine blades under various flow conditions. The turbine geometry and blade tilt angle were optimized based on the simulated wind velocity profiles derived from real-world vehicle flow patterns. Experimental validation through small-scale prototyping confirmed that optimal airflow angles, particularly around 120°, produce sufficient mechanical torque to rotate the turbine effectively. Results demonstrate that integrating small VAWTs into urban infrastructure, such as lighting poles, highway dividers, and sound barriers, can significantly enhance local energy recovery while improving the reliability of off-grid lighting systems. Overall, this research highlights the promising potential of VIT-based microgeneration systems to complement existing renewable energy sources, contributing to the realization of cleaner, smarter, and more resilient urban energy networks.