Andrew Rowe

Andrew Rowe

Auto-generated profile, based on publicly available information

Andrew Rowe

Department of Mechanical Engineering, Institute for Integrated Energy Systems, University of Victoria , 3800 Finnerty Rd., Victoria, British Colombia V8W 3P6, Canada

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Building Engineering
Verified
Journal Article
Closed access
BLBo Li
Bo Li
PWPeter Wild
Peter Wild
ARAndrew Rowe
Andrew Rowe

8 April 2025 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
PDPronob Das
Pronob Das
SMShahriar Mohtasim
Shahriar Mohtasim
ARAndrew Rowe
Andrew Rowe
KSKumar Abir Shuvo
Kumar Abir Shuvo
NMNusrat Jahan Mishuk
Nusrat Jahan Mishuk

14 July 2017 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
PGP Govindappa
P Govindappa
PTP V Trevizoli
P V Trevizoli
OCO Campbell
O Campbell
INI Niknia
I Niknia
TCT V Christiaanse
T V Christiaanse
ARA Rowe
A Rowe
This paper describes experimental performance data for MnFeP 1− x As x multilayer active magnetic regenerators. Five different matrices are tested: (i) one with three layers; (ii) one with six layers; and (iii) three, eight-layer regenerators where the layer thickness is varied. The tests are performed using a dual regenerator bespoke test apparatus based on nested Halbach permanent magnets. (PM II test apparatus at the University of Victoria.) Operating variables include displaced volume (3.8–12.65 cm 3 ), operating frequency (0.5–0.8 Hz) and hot-side rejection temperature (293–313 K). The results are mainly reported in terms of zero net load temperature span as a function of rejection temperature; a few tests with non-zero applied load are also presented. A maximum temperature span of 32 K is found for an eight-layer regenerator, which is similar to a previous work performed with gadolinium in the same experimental apparatus.

11 April 2014 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
PTPaulo V. Trevizoli
Paulo V. Trevizoli
JBJader R. Barbosa
Jader R. Barbosa
ATArmando Tura
Armando Tura
DADaniel Arnold
Daniel Arnold
ARAndrew Rowe
Andrew Rowe
The active magnetic regenerator (AMR) consists of a porous matrix heat exchanger whose solid phase is a magnetocaloric material (solid refrigerant) that undergoes a reversible magnetic entropy change when subjected to a changing magnetic field. The cooling capacity of the cycle is proportional to the mass of solid refrigerant, operating frequency, volumetric displacement of the heat transfer fluid and regenerator effectiveness. AMRs can be modeled via a porous media approach and a model has been developed in this work to simulate the time-dependent fluid flow and heat transfer processes in the regenerator matrix. Gadolinium (Gd) is usually adopted as a reference material for magnetic cooling at near room temperature and its magnetic temperature change and physical properties were accounted for through a combination of experimental data and the Weiss-Debye-Sommerfeld (WDS) theory. In this paper, the interaction of the applied magnetic field waveform with the heat transfer fluid displacement profile and the influence of demagnetizing effects on the AMR performance are investigated numerically. The numerical model is evaluated against experimental data for a regenerator containing spherical Gd particles.

1 July 2014 in Cryogenics
Verified
Journal Article
Closed access
TBThomas Burdyny
Thomas Burdyny
DADanny S. Arnold
Danny S. Arnold
ARAndrew Rowe
Andrew Rowe

27 March 2008 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
JSJ. P. Sass
J. P. Sass
JFJ. E. Fesmire
J. E. Fesmire
ZNZ. F. Nagy
Z. F. Nagy
SSS. J. Sojourner
S. J. Sojourner
DMD. L. Morris
D. L. Morris
JLJennifer Lock
Jennifer Lock
A technology demonstration test project was conducted by the Cryogenics Test Laboratory at the Kennedy Space Center (KSC) to provide comparative thermal performance data for glass microspheres, referred to as bubbles, and perlite insulation for liquid hydrogen tank applications. Two identical 1/15th scale versions of the 3,200,000 liter spherical liquid hydrogen tanks at Launch Complex 39 at KSC were custom designed and built to serve as test articles for this test project. Evaporative (boil-off) calorimeter test protocols, including liquid nitrogen and liquid hydrogen, were established to provide tank test conditions characteristic of the large storage tanks that support the Space Shuttle launch operations. This paper provides comparative thermal performance test results for bubbles and perlite for a wide range of conditions. Thermal performance as a function of cryogenic commodity (nitrogen and hydrogen), vacuum pressure, insulation fill level, tank liquid level, and thermal cycles will be presented.