16 September 2019 in Lasers in Medical Science
19 March 2023 in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
Антиоксидантное действие отрицательных аэроионов в коррекции печеночной дисфункции при механической желтухе
13 September 2024 in Journal of Venous Disorders
Objective. To evaluate vein wall and surrounding tissue damage during endovenous laser ablation (EVLA) with 1910 nm device and different settings. Material and methods. EVLA was performed in 2 sheep under general anesthesia. We used laser fibers with flat and radial tips, wavelength 1910 nm, power 1.5 W, 3 W and 4 W, laser fiber speed extraction 2 mm/sec. Macroscopic and microscopic assessment of damaged veins and surrounding vessels and nerves was carried out considering the distance between the vein wall and damaged structures. Results. Flat fiber at various powers contributed to eccentric vein wall damage up to perforation at a power of 4 W. Damage to perivascular vessels occurred at a distance of 1511±69.3 µm. Ablation with radial laser fiber damaged the vein wall uniformly. Ablation with 4 W damaged all layers of the vein wall. Thermal damage of perivascular vessels was observed at 457.5±30.6 µm from the vein wall. Conclusion. EVLA with 1910 nm laser and radial fibers makes it possible to reduce power to 3—4 W. This prevents vein wall perforation while all layers are damaged. Surrounding structures are damaged at a lesser distance if radial fiber is used.
12 November 2024 in Laser Medicine
Mechanisms of endovasal laser coagulation (EVLC) applied in varicose vein disease are not fully understood.Purpose. To analyze currently applied EVLC mechanisms so as to prevent hemorrhagic complications and paresthesia caused by these mechanisms.Methods. This review analyses modern theories on EVLC mechanisms when applied in varicose vein disease in the lower extremities.Results. Published experimental and clinical trials, including histological ones, have shown that the degree of vein damage during EVLC session depends on many factors, such as wavelength, intensity, and optical fiber speed. Damage to veins during EVLC procedure depends on various factors, such as direct contact of the vein wall with an optical fiber tip, carbonization of blood elements leading to the increased intravenous blood temperature and to the formation of gas bubbles as well as heat convection on the vein wall through the blood.Conclusion. Destruction of the vein wall during EVLC procedure is the result of a synergistic effect of various damaging factors. Currently, 2-μm laser irradiation is being implemented into clinical practice. This technique provides better vein coagulation under less power values which promotes less postoperative complications.