Soft-error tolerance depending on threshold voltage of transistors was evaluated by α -particle, heavy-ion, and neutron irradiation. Three chips were fabricated, one embeds low-threshold general-purpose (GP) transistors and the others embed high-threshold low-power (LP) transistors in a 65 nm fully depleted silicon on insulator (FDSOI) process. There were a few errors on LPDFFs (DFFs with LP transistors). Error probability (EP) of LPDFFs was 99.88% smaller than that of GPDFFs (DFFs with GP transistors) by α particles. Average cross sections (CSs) of LPDFFs by heavy ions were 50% smaller than those of GPDFFs. Average soft-error rates (SERs) of LPDFFs by neutrons were 68% smaller than those of GPDFFs. 3-D device simulations revealed that CSs of the LP and GP transistors are changed by fitting methods using the work function of the gate material and doping concentration of the substrate under the BOX layer. The difference is due to the number of carriers in diffusion and silicon thickness of the raised layer above drain and source terminals.
16 June 2020 in IEEE Transactions on Nuclear Science
We evaluated soft-error tolerance by neutrons and heavy ions on four types of flip flops (FFs) called D-type flip flop (DFF), guard-gate FF (GGFF), feedback recovery FF (FRFF), and dual FRFF (DFRFF) in a 65-nm thin buried oxide (BOX) fully depleted silicon on insulator (FDSOI). FRFF has a guard-gate structure only in the master latch. GGFF and DFRFF have the guard-gate structure in both master and slave latches. The guard-gate structure resolves a single-event transient (SET) pulse by delaying it through the guard gate. FRFF and DFRFF have smaller area and shorter delay overheads than GGFF. We revealed that the guard-gate structure has high soft-error tolerance by low-linear energy transfer (LET) heavy ions, but the larger-LET ions over 40 MeV-cm 2 /mg cause upset even in the guard-gate structures. We revealed that longer delay in the guard-gate can resolve these issues by circuit simulations.
23 April 2021 in IEEE Transactions on Nuclear Science
We found that specific pairs of pMOS and nMOS transistors in dual interlocked storage cell flip flop (DICEFF) become sensitive to soft errors by device simulations. We propose several layout structures that can improve soft-error tolerance with additional 39%-46% area overhead. We evaluated soft-error tolerance of a D-type FF (DFF) and DICEFFs in a 65-nm bulk process by heavy ions. Our experimental results showed that the DICEFF has more than 300× better soft-error tolerance than the DFF by Kr (LET 40.3 MeV·cm 2 /mg) irradiation when the supply voltage is 1.2 V, and the DICEFF has only 9× better soft-error tolerance than the DFF when the supply voltage is 0.6 V. However, the proposed DICEFF with 46% area overhead has 58× better soft-error tolerance than the DFF when the supply voltage is 0.6 V. DICEFF has so many sensitive pairs and lower soft-error tolerance as supply voltage decreases that cannot be applied to highly scaled process technologies.
1 April 2019 in IEEE Transactions on Nuclear Science
Flip-flops (FFs) with stacked transistors have high radiation tolerance in a fully-depleted silicon on insulator (FDSOI) process. However, the flip-flops are weak against a radioactive particle hit with high linear energy transfer (LET) and from high incident angles. In this study we used heavy-ion irradiation tests to evaluate the soft-error tolerance of a stacked structure and a radiation-hardened structure in an attempt to reduce sensitive range (RSR). We propose a novel flip-flop (FF) with the RSR structure. We fabricate a chip in a 65 nm FDSOI process with three latches, each with a different distances between stacked transistors. Experimental results reveal that the stacked structures are weak against a heavy-ion hit that exceeds a LET of 60 MeV-cm2/mg even though the distance between stacked transistors was increased from 250 nm to 350 nm. We evaluated the RSR structure by TCAD simulations and measured the radiation-hardness of the proposed FF by heavy-ion irradiation on the fabricated chips. Measurement by heavy ions with LET of 67.2 MeV-cm2/mg at all angles show no detectable errors in the proposed FF.