Tao Zhang

Tao Zhang

Auto-generated profile, based on publicly available information

Tao Zhang

Wuyi University,School of Civil Engineering and Architecture,Jiangmen,China,529020

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
Pengfei LiPengfei Li
Pengfei Li
TZTao Zhang
Tao Zhang
CWChengzhi Wang
Chengzhi Wang
The behavior of concrete‐filled steel tube (CFST) columns subjected to axial compression was experimentally investigated in this paper. Two kinds of columns, including CFST columns with foundation and columns without foundation, were tested. Columns of pure concrete and concrete with reinforcing bars as well as two steel tube thicknesses were considered. The experimental results showed that the CFST column with reinforcing bars has a higher bearing capacity, more effective plastic behavior, and greater toughness, and the elastoplastic boundary point occurs when the load is approximately 0.4–0.5 times of the ultimate bearing capacity. The change of rock‐socketed depth and the presence of steel tube will affect the ultimate bearing capacity of rock‐socketed pile. The bearing capacities of the rock‐socketed CFST columns are lower than those of rock‐socketed columns without a steel tube under a vertical load; besides, the greater the rock‐socketed depth, the greater the bearing capacity of the rock‐socketed piles. In addition, a numerical comparison between the ultimate load and the theoretical value calculated from the relevant specifications shows that the ultimate load is generally considerably greater than the theoretical calculation results.

6 November 2021
Verified
Conference Paper
Closed access
TZTao Zhang
Tao Zhang
YZYangsheng Zhang
Yangsheng Zhang
KCKongliang Chen
Kongliang Chen
Taking the 500 kV double-circuit transmission line jacking project as the background, aiming at the overturning phenomenon that may occur in the foundation of the high-voltage transmission tower jacking process, the finite element software is used to establish a three-tower six-line tower-line coupling system calculation model, considering the wires Numerical analysis of wind load response, self-weight effect of transmission tower, and tower-line coupling tension. The research results show that the y-direction bending moment value of each independent foundation will be significantly changed after the jacking, and the y-direction bending moment value of the sole base No. 2 will have a greater increase. In addition, the y-direction bending moment values of the upper and lower connecting beams cast in-situ after the transmission tower is lifted will suddenly increase, indicating that when the high-voltage transmission tower is lifted in situ, each foundation must be strengthened to avoid longitudinal restraints at the bottom of the foundation. Sudden instability of bending moment.