Volodymyr Kniaziev

Volodymyr Kniaziev

Auto-generated profile, based on publicly available information

Volodymyr Kniaziev

Науково-дослідний та проектно-конструкторський інститут «Молнія» Національного технічного університету «Харківський політехнічний інститут

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2023 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
VKV. V. Kniaziev
V. V. Kniaziev
Problem. Modern international standards in the field of lightning protection, when assessing the probability of a lightning strike into an object, do not take into account the statistical distribution of the lightning current. Goal. Justification of the expediency of taking into account the statistical distribution of the lightning current with a determined probability of lightning striking the elements of the object, and the effectiveness of the application of the improved «rolling sphere» method. Methodology. Method of mathematical modeling, based on RSM with additional consideration of the probability distribution of lightning current. Results. The expediency of taking into account the statistical distribution of lightning current at the determined probability of lightning striking the elements of the object has been proven. The effectiveness of the improved «rolling sphere» method, implemented in the form of a computer program, which takes into account the given probability distribution of lightning current in the range from 2 kA to 200 kA, has been proved. The expediency of introducing the concept of «average value of the area of the collection area» is substantiated, taking into account the probability of lightning with a current in a given range. It has been established that the application of the standardized formula leads to a significant (many times) overestimation of the predicted number of lightning strikes to the object, if the height of the object exceeds 20 m. The reasons for the difference, according to the author, are due to the following properties of the standardized methodology: usually, the real shape of the object is not taken into account; statistical distribution of lightning current is not taken into account; it is based on the results of experimental studies obtained mainly for mast or rod-type objects in laboratory conditions with a limited discharge interval. Practical value. This approach will provide an opportunity to optimize the layout of lightning arresters during the restoration of objects, taking into account green reconstruction. The obtained results are proposed for consideration by the Technical Committee TC 81 IEC for inclusion in the next editions of the standards.

1 September 2012
Verified
Conference Paper
Closed access
OSOleksii Skoblikov
Oleksii Skoblikov
VKVolodymyr Kniaziev
Volodymyr Kniaziev
The paper provides an overview on the past research activities and summarizes the main results on the study aimed at design and implementation of an online method for diagnostics of shielding effectiveness for real conductive shields. The review starts with the results of theoretical investigations on shielding electromagnetic fields with structurally irregular low permeability enclosures in quasi-statics and resonant modes. Then we address the motivation for and list the main features of a novel hybrid simulation method we designed for quasi-statics. Inspired by the theoretical advances and promising experimental results, we propose the prototype method for online diagnostics of shielding effectiveness of electromagnetic enclosures. Finally, we discuss the means and approaches for practical implementation of the proposed method in an intellectual self-diagnostic system.

1 January 2021 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
MBM.I. Baranov
M.I. Baranov
SBS.G. Buriakovskyi
S.G. Buriakovskyi
VKV.V. Kniaziev
V.V. Kniaziev
Goal Development of engineering method for settlement of threshold amplitudes I-mpk of single pulse current i(p)(t) of different temporal shapes for electric wires and cables with polyethylene (PET), polyvinylchloride (PVC) and rubber (R) half-length insulation, used in modern pulsed power engineering, electrical engineering and electronics in their low- and high-current circuits. Methodology. Basis of the theoretical and applied electrical engineering, electrical power engineering, electrophysics bases of technique of high-voltage and large pulsed currents, bases of low- and high-current electronics, measuring technique, electromagnetic compatibility and standardization. Results. Development of engineering method is executed on close calculation determination of threshold amplitudes I-mpk of single-pulse axial-flow current i(p)(t) of different temporal shapes for electric wires and cables with copper (aluminum) current-carrying parts and PET, PVC and R half-length insulation, used in the ow- and high-current circuits of pulsed electrical power engineering, electrical engineering and electronics. Electrothermal resistibility of half-length insulation of the examined cable and wire products (CWP), proper maximum to the possible temperatures of heating of current-carrying and insulating parts of the probed wires and cables and shutting out the offensive of the phenomenon destruction in the indicated insulation of CWP, was fixed based on this method. Calculation analytical correlations are obtained for finding in probed CWP of threshold numeral values of I-mpk amplitudes of pulses of current i(p)(t), time-varying both on aperiodic dependence of type tau(f)-tau(p) with duration of their front tau(f) and duration of their pulses tau(p) and by law of exponential attenuation sinewave. It is shown that at I-mp>I-mpk destruction of their half-length insulation, resulting in the decline of service life of CWP, will come from the thermal overheat of current-carrying parts of the examined electric wires and cables. The examples of practical application of the offered method are resulted upon settlement for a radiofrequency coaxial cable RC 50-4-11 with middle sizes is easily soiled with continuous PET insulation of threshold amplitudes of I-mpk of standard aperiodic pulses of current i(p)(t) from nano-, micro- and millisecond temporal ranges of shape of tau(f)/tau(p)=5 ns/200 ns, tau(f)/tau(p)=10 mu s/350 mu s and tau(f)/tau(p)=7 ms/160 ms. It is shown that with the proper growth of parameter tau(p) >> tau(f) for flow on a continuous copper tendon and split copper shell of radiofrequency coaxial cable RC 50-4-11 with middle sizes is easily soiled indicated homopolar pulses of current i(p)(t) substantial diminishing of their threshold amplitudes of I-mpk (with 531,2 kappa A for the nanosecond pulse of current of type 5 ns/200 ns to 1.84 kappa A for the millisecond impulse of current of type of 7 ms/160 ms takes place). Originality. An engineering method is first developed for close settlement of threshold numeral values of I-mpk amplitudes of single pulse axial-flow current i(p)(t) of arbitrary peak-temporal parameters for electric wires and cables with copper (aluminum) current-carrying parts and PET, PVC and R half-length insulation. Practical value. Application in electrical engineering practice of the offered engineering method for determination of threshold amplitudes I-mpk of the indicated pulses of axial-flow current i(p)(t) for the probed electric wires and cables will allow considerably to increase service life of examined CWP.

25 February 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
VKVolodymyr Knyazev
Volodymyr Knyazev
VKVladimir Kravchenko
Vladimir Kravchenko
BLBogdan Lazurenko
Bogdan Lazurenko
OSOleksandr Serkov
Oleksandr Serkov
KTKaryna Trubchaninova
Karyna Trubchaninova
NPNataliia Panchenko
Nataliia Panchenko
It has been shown that existing methods and models for improving the noise immunity of communication channels are not capable of meeting requirements for the quality of information in mobile infocommunication systems. In addition, the compromised quality of information fails to protect it and provide the speed of information transmission and density of access channels. It has been proven that reducing the level of electromagnetic radiation is the main method of ensuring noise immunity in wireless mobile communication systems of infocommunication systems. Therefore, one way to ensure the stable interference-free operation is to reduce the level of the information signal at the receiver input to the noise level when the signal/noise ratio is equal to one. This paper reports the results of studying methods and models with correlation reception of ultra-wideband signals. It is proved that according to the level of potential noise immunity, the best indicators are shown by the model of encoding an ultra-wideband information signal by phase manipulation, followed by the coding model with opposite chips, and the code-time manipulation model. It is shown that with a large base of the signal B>300 when the intensity of the received signals is below the level of interference, reliable transmission of information is carried out with a probability of error of less than 10-6. This proves that the use of ultra-wide signal technology allows for wireless hidden transmission of information with low radiation power and a low probability of error. Thus, at a speed of 12 Mb/s, it is possible to chain the transmission of information with a probability of error less than 10-6 if there is a large signal base used, B =500‒1000.

4 January 2023 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
MBM. I. Baranov
M. I. Baranov
SBS. G. Buriakovskyi
S. G. Buriakovskyi
VKV. V. Kniaziev
V. V. Kniaziev
Goal. Receipt and analysis of close analytical correlations for the engineering calculation of maximal temperature of Tm and pressures of Pm in a plasma channel, time of tex explosion of explorer, active resistance of Rc and specific conductivity of γp of plasma channel, to entered in explorer Wi and selected in the channel of Wc of thermal energy and high speed of vmw distribution of shock acoustic wave in the plasma products of electric explosion (EE) in gas of explorer under the action of large impulsive current (LIC). Methodology. Basis of thermophysics, thermodynamics, theoretical and applied electrical engineering, electrophysics bases of technique of high-voltage and large impulsive currents, basis of heavy-current electronics, theory of explosion and plasma, measuring technique and electromagnetic compatibility. Results . Close formulas are got for the analytical calculation of temperature of Tm and pressures of Pm in a plasma channel, time of tex explosion of explorer, active resistance of Rc and specific conductivity of γp of plasma channel, to entered in explorer Wi and selected in the channel of Wc of thermal energy and speed of vmw of shock acoustic wave in «metallic plasma» at EE in gas of explorer, testing action LIC in the discharge chain of high-voltage generator of impulsive currents (GIC) with the stocked energy of W0. It is rotined that at EE in atmospheric air of copper explorer long 110 mm and by a radius 0,1 mm in the bit chain of GIC of the microsecond temporal range (Imc≈−190 кА; tmc≈42 μs; ωc≈26,18·103 s-1; W0≈121,4 кJ) levels of temperature of Tm, to time of tex explosion, pressures of Pm and speeds of vmw in the area of his explosion can arrive at numeral values: Tm≈121,6·103 K, tex≈3,32 μs; Pm≈14,19·109 Pa and vmw≈4693 m/s. The ways of receipt are formulated in the bit chain of GIC of «record» (most) values of temperature of Tm, pressures of Pm and speeds of vmw. It is set that at EE in atmospheric air of the indicated short thin copper explorer the coefficient of the useful use of ηc of electric energy of W0 of condenser battery of GIC arrives at the numeral value of ηc≈(Wi+Wc)/W0≈0,326 (32,6 %). Arising up in the plasma channel of discharge, initiated EE in gas of explorer, temperature of Tm and pressure of Pm, time of tex explosion of explorer, specific conductivity of γp of channel, thermal energy of Wc and speed of vmw of shock acoustic wave selected in a channel in «metallic plasma» can be certain experimental a way on results decoding of oscillograms of discharge current of ic(t) and high-voltage of uc(t) on an explorer in the chain of GIC. A formula is resulted for the close calculation of critical integral of current of Jk at EE in gas of explorers from different metals. Executed on powerful GIC heavy-current experiments were confirmed by substantive provisions offered approach near the analytical calculation of basic parameters of electro-explosive process for the probed explorer. Originality. Offered and the engineering going is scientifically grounded near the analytical calculation of the indicated thermophysical, gasodynamic and electroenergy parameters of Tm, Pm, tex, Rc, γp, Wi, Wc and vmw at EE in gas of metallic explorer, plugged in the discharge chain of GIC. Practical value. Application in electrophysics practice of the offered engineering going near a calculation in the chain of GIC of basic parameters of electro-explosive process will allow to facilitate labour of workers of scientific laboratories and promote efficiency of work of technicians-and-engineers during practical realization by them different electro-explosive technologies.

1 September 2010
Verified
Conference Paper
Closed access
VKV. V. Kniaziev
V. V. Kniaziev
VKV. I. Kravchenko
V. I. Kravchenko
YNYu. S. Niemchenko
Yu. S. Niemchenko
ILI. P. Lisnoy
I. P. Lisnoy
The article describes a TEM-method for calibrating high-voltage pulse dividers. The method is based on Etalon-EMP use. It presents the results of method use for determining transient response form and rise time of five types of high-dividers of various designs. The article shows the advantages of this method compared with the known methods.