Shin-Woong Park

Shin-Woong Park

Auto-generated profile, based on publicly available information

Shin-Woong Park

Korea University

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2020 in Optics Express
Verified
Journal Article
Open access
JLJun Ho Lee
Jun Ho Lee
BYByeong Geon You
Byeong Geon You
SPShin-Woong Park
Shin-Woong Park
HKHwi Kim
Hwi Kim
Through-focus scanning optical microscopy (TSOM) is a model-based optical metrology method that involves the scanning of a target through the focus of an optical microscope. Unlike a conventional optical microscope that directly extracts the diffraction-limited optical information from a single in-focus image, the TSOM method extracts nanometer scale sensitive information by matching the target TSOM data/image to reference TSOM data/images that are either experimentally or computationally collected. Therefore, the sensitivity and accuracy of the TSOM method strongly depends on the similarities between the conditions in which the target and reference TSOM images are taken or simulated, especially the lateral instability during through-focus scanning. As a remedy to the lateral instability, we proposed the application of adaptive optics to the through-focus scanning operation and initially developed a closed-loop system with a tip/tilt mirror and a Shack-Hartmann sensor, with which we were able to keep the plane position within peak-to-valley (PV) 33 nm. We then further developed a motion-free TSOM tool reducing the instability down to practically zero by the replacement of the tip/tilt mirror with a deformable mirror that performs through-focus scanning by deforming its mirror surface. The motion-free TSOM tool with a × 50 (NA 0.55) objective lens could provide a scanning range of up to ± 25 µm with a minimum step of 25 nm at a maximum update rate of 4 kHz. The tool was demonstrated to have a recognition accuracy of < 4 nm for critical dimension (CD) values in the range of 60 ∼ 120 nm with a reference TSOM image library generated by a Fourier modal method matching various observations conditions.

1 November 2006 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SPShin-Woong Park
Shin-Woong Park
SYSunwoo Yuk
Sunwoo Yuk
JRJun Seok Ryu
Jun Seok Ryu
MKMin Suk Kim
Min Suk Kim
YYYun Yi
Yun Yi

12 December 2022 in Optics Letters
Verified
Journal Article
Closed access
SPSungjae Park
Sungjae Park
JLJonghyun Lee
Jonghyun Lee
WCWonwoo Choi
Wonwoo Choi
SPShin-Woong Park
Shin-Woong Park
HKHwi Kim
Hwi Kim
In the depth-map computer-generated hologram (CGH), inter-layer edge artifacts are observed in the discontinuous edges of section-wise depth-map objects. CGH synthesis, utilizing the hybrid smoothing method of silhouette masking and edge-apodization, alleviates unwanted inter-layer edge artifacts. The proposed method achieves improved de-artifact filtering that generates holographic images closer to the ground truth image of the depth-map object unattainable by the conventional CGH synthesis method.

20 December 2024 in Optics Express
Verified
Journal Article
Closed access
JLJonghyun Lee
Jonghyun Lee
MCMyeonggyu Choi
Myeonggyu Choi
SJSehyeon Jeong
Sehyeon Jeong
SPShin-Woong Park
Shin-Woong Park
HKHwi Kim
Hwi Kim
We present the Fourier coupled modal method (FCMM) as a solution for large-scale photonic structure analysis, emphasizing its inherent parallelism, facilitated by spatial partitioning and Fourier modal field computation. The parallelism of the FCMM is achieved by integrating the coupled mode theory (CMT) within the Fourier modal method (FMM). The proposed numerical framework of the FCMM is detailed and validated through a comparative study with the conventional FMM.

1 January 2007
Verified
Conference Paper
Closed access
SPShin-Woong Park
Shin-Woong Park
YYYun Yi
Yun Yi
SYSunwoo Yuk
Sunwoo Yuk
An integrated circuit for charge sensitive amplifier (CSA) was developed for X-ray detection. The circuit has been optimized for reading signals from silicon strip detectors with few pF input capacitance for low power and low noise. Theoretical calculations and optimizations are presented and compared with experimental results. Noise as low as 237 ENC [electrons] was obtained including a silicon detector of 1.3 pF and 0.386 pA of leakage. The power consumption was less than 100 W. Other circuit parameters were also obtained from experiments. The circuit was fabricated in standard 0.25 um CMOS technology and the circuit occupies an area of 4 mm times 4 mm.

6 July 2026 in Optics Letters
Verified
Journal Article
Closed access
SNSehwan Na
Sehwan Na
JLJonghyun Lee
Jonghyun Lee
MCMyeonggyu Choi
Myeonggyu Choi
SPShinwoong Park
Shinwoong Park
HKHwi Kim
Hwi Kim
A complex spatial light modulator (SLM) based on three-phase covalent macropixels (3PCMPs) enables the generation of three-dimensional computer-generated holograms with inherent suppression of DC and conjugate noise. However, the noise-suppressed complex-field synthesis remains confined to the central viewing zone (VZ), imposing a fundamental limitation on the effective eye-box. We present a design of zone-switching 3PCMP SLM architecture that relocates the domain of noise-suppressed complex-field synthesis across a 3 × 3 array of addressable VZs in a pupil-tracked manner. The proposed scheme integrates a static six-level phase plate with active binary sub-pixel modulation to steer the complex signal toward the selected VZ while preserving suppression of DC and conjugate terms. Wave-optics simulations confirm effective zone switching of the complex signal and show substantially improved holographic image quality across higher-order VZs, enabling a 3 × 3 extension of the effective viewing zone. These results support the feasibility of extending the effective eye-box in complex holographic displays.