Laura Rubio

Laura Rubio

Auto-generated profile, based on publicly available information

Laura Rubio

Department of Chemistry, Faculty of Sciences, Universidad de Burgos, Plaza Misael Bañuelos s/n, 09001 Burgos, Spain

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Chemometrics and Intelligent Laboratory Systems
Verified
Journal Article
Open access
LRL. Rubio
L. Rubio
SSS. Sanllorente
S. Sanllorente
LSL.A. Antomio Sarabia
L.A. Antomio Sarabia
MOM. Cruz Ortiz
M. Cruz Ortiz
In this work, a headspace solid-phase microextraction and gas chromatography coupledwith mass spectrometry\ud (HS-SPME-GC/MS) method for trace determination of primary aromatic amines was developed. The following\ud analytes were investigated: aniline (A), 4,4′-diaminodiphenylmethane (4,4′-MDA) and 2,4-diaminotoluene\ud (2,4-TDA) using 3-chloro-4-fluoroaniline (3C4FA) and 2-aminobiphenyl (2ABP) as internal standards. Prior to\ud extraction the analytes were derivatized in the aqueous solution by diazotation and subsequent iodination.\ud The derivativeswere extracted byHS-SPME using a PDMS/DVB fiber and analyzed by GC/MS. A D-optimal design\ud was used to study the parameters affecting the HS-SPME procedure and the derivatization step. Two experimental\ud factors at two levels and one factor at three levels were considered: (i) reaction time, (ii) extraction temperature,\ud and (iii) extraction time in the headspace. The interaction between the extraction temperature and\ud extraction time was considered in the proposed model. The loadings in the sample mode estimated by a\ud PARAFAC (parallel factor analysis) decomposition for each analyte were the response used in the design because\ud they are proportional to the amount of analyte extracted. The optimum conditions for the best extraction of the\ud analytes were achieved when the reaction time was 20 min, the extraction temperature was 50 °C and the\ud extraction time was 25 min. The interaction was significant.\ud A calibration based on a PARAFAC decomposition provided the following values of decision limit (CCα): 1.07 μgL−1\ud for A, 1.23 μg L−1 for 2,4-TDA and 0.83 μg L−1 for 4,4′-MDA for a probability of false positive fixed at 5%. Also, the\ud accuracy (trueness and precision) of the procedurewas assessed. Furthermore, all the analyteswere unequivocally\ud identified.\ud Finally, the method was applied to spiked water samples and polyamide cooking utensils (spoons). 3% (w/v)\ud acetic acid in aqueous solution was used as food simulant for testing migration from polyamide kitchenware.\ud Detectable levels of 4,4′-diaminodiphenylmethane and aniline were found in food simulant from some of the\ud investigated cooking utensils.Ministerio de Economía y Competitividad (CTQ2011-26022) and Junta\ud de Castilla y León (BU108A11-2

1 June 2015 in Talanta
Verified
Journal Article
Open access
LRL. Rubio
L. Rubio
LSL.A. Antomio Sarabia
L.A. Antomio Sarabia
MOM. Cruz Ortiz
M. Cruz Ortiz
The simultaneous determination of two carbamate pesticides (carbaryl and carbendazim) and of the degradation product of carbaryl (1-naphthol) in iceberg lettuce was achieved by means of PARAFAC decomposition and excitation-emission fluorescence matrices. A standard addition method for a calibration based on four-way data was applied using different dilutions of the extract from iceberg lettuce as a fourth way that provided the enough variation of the matrix to carry out the four-way analysis. A high fluorescent overlapping existed between the three analytes and the fluorophores of the matrix. The identification of two fluorescent matrix constituents through the four-way model enabled to know the matrix contribution in each dilution of the extract. This contribution was subtracted from the previous signals and a subsequent three-way analysis was carried out with the tensors corresponding to each dilution. The PARAFAC decomposition of these resulting tensors showed a CORCONDIA index equal to 99%. For the identification of the analytes, the correlation between the PARAFAC spectral loadings and the reference spectra has been used. The trueness of the method, in the concentration range studied, was guaranteed because there was neither constant nor proportional bias according to the appropriate hypothesis tests. The best recovery percentages were obtained with the data from the most diluted extract, being the results: 127.6% for carbaryl, 125.55% for carbendazim and 87.6% for 1-naphthol. When the solvent calibration was performed, the decision limit (CCα) and the capability of detection (CCβ) values, in x0=0, were 2.21 and 4.38 μg L(-1) for carbaryl, 4.87 and 9.64 μg L(-1) for carbendazim; and 3.22 and 6.38 μg L(-1) for 1-naphthol, respectively, for probabilities of false positive and false negative fixed at 0.05. However, these values were 5.30 and 10.49 μg L(-1) for carbaryl, 18.05 and 35.73 μg L(-1) for carbendazim; and 1.92 and 3.79 μg L(-1) for 1-naphthol, respectively, when the matrix-matched calibration using the most diluted extract was carried out in the recovery study.


1 April 2014 in Analytica Chimica Acta
Verified
Journal Article
Open access
LRL. Rubio
L. Rubio
MOM. Cruz Ortiz
M. Cruz Ortiz
LSL.A. Antomio Sarabia
L.A. Antomio Sarabia
A non-separative, fast and inexpensive spectrofluorimetric method based on the second order calibration of excitation-emission fluorescence matrices (EEMs) was proposed for the determination of carbaryl, carbendazim and 1-naphthol in dried lime tree flowers. The trilinearity property of three-way data was used to handle the intrinsic fluorescence of lime flowers and the difference in the fluorescence intensity of each analyte. It also made possible to identify unequivocally each analyte. Trilinearity of the data tensor guarantees the uniqueness of the solution obtained through parallel factor analysis (PARAFAC), so the factors of the decomposition match up with the analytes. In addition, an experimental procedure was proposed to identify, with three-way data, the quenching effect produced by the fluorophores of the lime flowers. This procedure also enabled the selection of the adequate dilution of the lime flowers extract to minimize the quenching effect so the three analytes can be quantified. Finally, the analytes were determined using the standard addition method for a calibration whose standards were chosen with a D-optimal design. The three analytes were unequivocally identified by the correlation between the pure spectra and the PARAFAC excitation and emission spectral loadings. The trueness was established by the accuracy line "calculated concentration versus added concentration" in all cases. Better decision limit values (CCα), in x0=0 with the probability of false positive fixed at 0.05, were obtained for the calibration performed in pure solvent: 2.97 μg L(-1) for 1-naphthol, 3.74 μg L(-1) for carbaryl and 23.25 μg L(-1) for carbendazim. The CCα values for the second calibration carried out in matrix were 1.61, 4.34 and 51.75 μg L(-1) respectively; while the values obtained considering only the pure samples as calibration set were: 2.65, 8.61 and 28.7 μg L(-1), respectively.


1 September 2016 in Journal of Chromatography A
Verified
Journal Article
Open access
MOM.L. Oca
M.L. Oca
LRL. Rubio
L. Rubio
LSL.A. Antomio Sarabia
L.A. Antomio Sarabia
MOM. Cruz Ortiz
M. Cruz Ortiz
Determining plasticizers and other additives migrated from plastic materials becomes a hard task when these substances are already present in the laboratory environment. This work dealt with this drawback in the multiresidue determination of four plasticizers (2,6-di-tert-butyl-4-methyl-phenol (BHT), diisobutyl phthalate (DiBP), bis(2-ethylhexyl) adipate (DEHA) and diisononyl phthalate (DiNP)) and a UV stabilizer (benzophenone (BP)) by gas chromatography/mass spectrometry (GC/MS) using DiBP-d4 as internal standard. The ubiquity of DiBP by a non-constant leaching process in the laboratory was detected, which could not guarantee the achievement of a trustworthy quantification. To handle this, the assessment of the level of DiBP in solvent blanks having fixed the probabilities of false non-compliance (α) and false compliance (β) at 0.01 was performed. On the other hand, another special case was that of DiNP, in whose chromatogram finger peaks appear because of an array of possible C9 isomers. PARAFAC, used for the identification and quantification of all the substances, is a useful chemometric tool that enabled a more reliable determination of this analyte since no peak areas were considered but chromatographic and spectral loadings. Since phthalates may migrate from rubber latex items, an evaluation of the existence of matrix effects on the determination of the five analytes was conducted prior to an extraction with hexane from a dummy for infants. As matrix effects were present, the quantification of the compounds under study was performed following the standard addition method using PARAFAC sample loadings as response variable. As a result, the presence of BHT was confirmed, being its concentration equal to 37.87μgL(-1). Calibrations based on PARAFAC yielded the following values for the decision limit (CCα): 1.16μgL(-1) for BHT, 1.34μgL(-1) for BP, 1.84μgL(-1) for DEHA and 51.42μgL(-1) for DiNP(for α=0.05 and two replicates).