Background: Stroke is one of the major causes of morbidity and mortality. Its recovery and treatment depends on close clinical monitoring by a clinician especially during the first few hours after the onset of stroke. Patients who do not exhibit early motor recovery post thrombolysis may benefit from more aggressive treatment.Method: A novel approach for monitoring stroke during the first few hours after the onset of stroke using a wireless accelerometer based motor activity monitoring system is developed. It monitors the motor activity by measuring the acceleration of the arms in three axes. In the presented proof of concept study, the measured acceleration data is transferred wirelessly using iMote2 platform to the base station that is equipped with an online algorithm capable of calculating an index equivalent to the National Institute of Health Stroke Score (NIHSS) motor index. The system is developed by collecting data from 15 patients.Results: We have successfully demonstrated an end-to-end stroke monitoring system reporting an accuracy of calculating stroke index of more than 80%, highest Cohen’s overall agreement of 0.91 (with excellentκcoefficient of 0.76).Conclusion: A wireless accelerometer based ‘hot stroke’ monitoring system is developed to monitor the motor recovery in acute-stroke patients. It has been shown to monitor stroke patients continuously, which has not been possible so far with high reliability.
1 July 2017 in Journal of Stroke and Cerebrovascular Diseases
Background: Clinical deterioration in the acute stage of ischemic stroke powerfully predicts outcome and may serve as a marker for urgent intervention. However, accurate monitoring of acute stroke patients is hampered by the lack of validated continuous monitoring devices. We sought to assess the use of wireless accelerometry in this setting, hypothesizing that stroke patients would have a greater difference in movement between upper limbs than controls and that the magnitude of correlation between upper limb movements would be negatively associated with the National Institutes of Health Stroke Scale (NIHSS) score. Methods: In this pilot study, 20 patients with acute ischemic stroke and unilateral upper limb weakness and 10 controls were recruited from a comprehensive stroke centre. All subjects were fitted with two 3-axis accelerometers and underwent 24 h of continuous accelerometry recording of upper limb movements and repeat NIHSS assessments. The intra-class correlation coefficient (ICC), assessing the similarity (or otherwise) of spontaneous movements in each arm was calculated. The association between NIHSS (total and motor subset scores) and the magnitude of ICC was estimated by Spearman's rank correlation, receiver-operating characteristic curve analysis was performed and the optimal diagnostic threshold value of ICC was calculated. Results: The magnitude of the ICC was significantly associated with the baseline NIHSS score (p = 0.02) and non-significantly associated with the baseline NIHSS motor score (p = 0.08). At the optimal diagnostic threshold of ICC magnitude = 0.7, wireless accelerometry distinguished patients from controls with a sensitivity of 0.95, a specificity of 0.6 and a diagnostic odds ratio of 28.5. Conclusions: The wireless accelerometry system successfully detects a motor deficit in the setting of acute ischemic stroke, accurately differentiating patients from controls, and correlates well with the baseline NIHSS score. Its use is feasible in the acute stroke setting. Overall, it shows promise as a diagnostic tool to continuously monitor acute stroke patients but requires validation in a larger trial.
1 September 2021 in Annals of Translational Medicine
Effect of stroke screening survey on intravenous thrombolysis and long-term outcomes in acute ischemic stroke patients: the real- world evidence from Shanghai, China Fen Li, Yuqian Chen, Lan Hong, Bifan Zhu, Duo Chen, Xinyu Qin, Guangfeng Gao, Jianhua Xu, Xin Cheng, Qiang Dong, Chunlin Jin, Kun Fang
1 September 2021 in Communications in Nonlinear Science and Numerical Simulation