14 October 2019 in IEEE Transactions on Instrumentation and Measurement
In this study, we propose a cuff-less blood pressure (BP) estimation technique based on deep learning for smart wristwatches. Photoplethysmography (PPG) and electrocardiography (ECG) signals are first collected from the sensors installed at a smart wristwatch. Ground truth systolic BP (SBP) and diastolic BP (DBP) measurements are then obtained by a reference device, a mercury sphygmomanometer. In order to estimate the SBP and DBP, we extract feature vectors and reconstruct them through a feature selection process. Next, we design two-stage system of a stacked deep neural network (DNN)-based SBP and DBP estimation models and compare our results to those obtained using estimation techniques in the previously reported algorithms such as the polynomial regression (PR), support vector machine (SVM), artificial neural network (ANN), and deep belief network (DBN)-DNN. In order to verify the proposed algorithm against the conventional algorithms, we quantitatively compare the results in terms of mean error (ME) with standard deviation, mean absolute error (MAE) with standard deviation, Pearson correlation, box plot, and Bland-Altman plot. For this, 110 subjects contributed to the database (DB), each of which is collected three times for 20 seconds. The quantitative errors turn out lower compared to the existing methods, which shows the superiority of our approach. To further enhance the BP estimation performance for each individual user, we devise the personal adaptation algorithm for the BP estimation algorithm that yields better the BP estimates.
16 August 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Sarcopenia is a comprehensive degenerative disease with the progressive loss of skeletal muscle mass with age, accompanied by the loss of muscle strength and muscle dysfunction. Individuals with unmanaged sarcopenia may experience adverse outcomes. Periodically monitoring muscle function to detect muscle degeneration caused by sarcopenia and treating degenerated muscles is essential. We proposed a digital biomarker measurement technique using surface electromyography (sEMG) with electrical stimulation and wearable device to conveniently monitor muscle function at home. When motor neurons and muscle fibers are electrically stimulated, stimulated muscle contraction signals (SMCSs) can be obtained using an sEMG sensor. As motor neuron activation is important for muscle contraction and strength, their action potentials for electrical stimulation represent the muscle function. Thus, the SMCSs are closely related to muscle function, presumptively. Using the SMCSs data, a feature vector concatenating spectrogram-based features and deep learning features extracted from a convolutional neural network model using continuous wavelet transform images was used as the input to train a regression model for measuring the digital biomarker. To verify muscle function measurement technique, we recruited 98 healthy participants aged 20–60 years including 48 [49%] men who volunteered for this study. The Pearson correlation coefficient between the label and model estimates was 0.89, suggesting that the proposed model can robustly estimate the label using SMCSs, with mean error and standard deviation of -0.06 and 0.68, respectively. In conclusion, measuring muscle function using the proposed system that involves SMCSs is feasible.
1 March 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
We propose a digital biomarker related to muscle strength and muscle endurance (DB/MS and DB/ME) for the diagnosis of muscle disorders based on a multi-layer perceptron (MLP) using stimulated muscle contraction. When muscle mass is reduced in patients with muscle-related diseases or disorders, measurement of DBs that are related to muscle strength and endurance is needed to suitably recover damaged muscles through rehabilitation training. Furthermore, it is difficult to measure DBs using traditional methods at home without an expert; moreover, the measuring equipment is expensive. Additionally, because traditional measurements depend on the subject’s volition, we propose a DB measurement technique that is unaffected by the subject’s volition. To achieve this, we employed an impact response signal (IRS) based on multi-frequency electrical stimulation (MFES) using an electromyography sensor. The feature vector was then extracted using the signal. Because the IRS is obtained from stimulated muscle contraction, which is caused by electrical stimulation, it provides biomedical information about the muscle. Finally, to estimate the strength and endurance of the muscle, the feature vector was passed through the DB estimation model learned through the MLP. To evaluate the performance of the DB measurement algorithm, we collected the MFES-based IRS database for 50 subjects and tested the model with quantitative evaluation methods using the reference for the DB. The reference was measured using torque equipment. The results were compared with the reference, indicating that it is possible to check for muscle disorders which cause decreased physical performance using the proposed algorithm.
1 January 2024 in Brain & Neurorehabilitation
Song K, et al. Brain Neurorehabil. 2024 Jun;17(2):e12. https://doi.org/10.12786/bn.2024.17.e12