Andrew Taylor

Andrew Taylor

Auto-generated profile, based on publicly available information

Andrew Taylor

Centre for Cardiovascular Imaging, Heart and Lung Division, Great Ormond Street Hospital for Children NHS Foundation Trust

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2024 in JMIR Medical Informatics
Verified
Journal Article
Open access
EAElham Asgari
Elham Asgari
JKJapsimar Kaur
Japsimar Kaur
GNGani Nuredini
Gani Nuredini
JBJasmine Balloch
Jasmine Balloch
ATAndrew M Taylor
Andrew M Taylor
DPDominic Pimenta
Dominic Pimenta
The cognitive load theory suggests that completing a task relies on the interplay between sensory input, working memory, and long-term memory. Cognitive overload occurs when the working memory’s limited capacity is exceeded due to excessive information processing. In health care, clinicians face increasing cognitive load as the complexity of patient care has risen, leading to potential burnout. Electronic health records (EHRs) have become a common feature in modern health care, offering improved access to data and the ability to provide better patient care. They have been added to the electronic ecosystem alongside emails and other resources, such as guidelines and literature searches. Concerns have arisen in recent years that despite many benefits, the use of EHRs may lead to cognitive overload, which can impact the performance and well-being of clinicians. We aimed to review the impact of EHR use on cognitive load and how it correlates with physician burnout. Additionally, we wanted to identify potential strategies recommended in the literature that could be implemented to decrease the cognitive burden associated with the use of EHRs, with the goal of reducing clinician burnout. Using a comprehensive literature review on the topic, we have explored the link between EHR use, cognitive load, and burnout among health care professionals. We have also noted key factors that can help reduce EHR-related cognitive load, which may help reduce clinician burnout. The research findings suggest that inadequate efforts to present large amounts of clinical data to users in a manner that allows the user to control the cognitive burden in the EHR and the complexity of the user interfaces, thus adding more “work” to tasks, can lead to cognitive overload and burnout; this calls for strategies to mitigate these effects. Several factors, such as the presentation of information in the EHR, the specialty, the health care setting, and the time spent completing documentation and navigating systems, can contribute to this excess cognitive load and result in burnout. Potential strategies to mitigate this might include improving user interfaces, streamlining information, and reducing documentation burden requirements for clinicians. New technologies may facilitate these strategies. The review highlights the importance of addressing cognitive overload as one of the unintended consequences of EHR adoption and potential strategies for mitigation, identifying gaps in the current literature that require further exploration.

21 February 2022 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
MPMarina Patriarca
Marina Patriarca
NBNicola Barlow
Nicola Barlow
ACAlan Cross
Alan Cross
SHSarah Hill
Sarah Hill
ARAnna Robson
Anna Robson
JTJulian Tyson
Julian Tyson
This review discusses developments in elemental mass spectrometry, atomic absorption, emission and fluorescence, XRF and LIBS, as applied to the analysis of specimens of clinical interest, foods and beverages. Sample preparation procedures and quality assurance are also included.

20 March 2019 in Prenatal Diagnosis
Verified
Journal Article
Open access
PDF file
SSSusan C. Shelmerdine
Susan C. Shelmerdine
OAOwen J. Arthurs
Owen J. Arthurs
IGIsobel Gilpin
Isobel Gilpin
WNWendy V. Norman
Wendy V. Norman
RJRod Jones
Rod Jones
LCLyn Chitty
Lyn Chitty
Objective: To determine the additional yield from autopsy following prenatal ultrasound and post‐mortem magnetic resonance imaging (PMMR) for structural abnormalities.Method: PMMR was performed on consecutive fetuses over a 6‐year period. Prenatal ultrasound and PMMR findings were categorised as concordant, partially concordant or discordant findings. The yield of new and clinically significant information from autopsy was assessed. Diagnostic accuracies for both modalities were calculated, using autopsy as reference standard.Results: Our study consisted of 81 fetuses. PMMR and prenatal ultrasound findings were concordant in 44/81 (54.3%), partially concordant in 26/81 (32.1%) and discordant in 11/81 (13.6%) cases. In 19/81 cases (23%), autopsy provided additional information, which appeared clinically significant in 12 cases. In 10 of those 12 cases, there was discordance between PMMR and ultrasound. In only 2 of 44 cases where ultrasound and PMMR were concordant, did autopsy provide clinically significant information.Diagnostic accuracy rates for ultrasound were sensitivity of 76.8% (66.6%, 84.6%), specificity of 92.5% (88.9%, 95.0%). For PMMR the sensitivity was 79.0% (68.9%, 86.5%), specificity 97.9% (95.5%, 99.0%). PMMR had a significantly higher concordance rate with autopsy than ultrasound (89.0 vs 93.8%; P < .001).Conclusion: Where PMMR and ultrasound are concordant, there is little additional yield from autopsy.

5 December 2014 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
JBJoy L. Barber
Joy L. Barber
NSNeil J. Sebire
Neil J. Sebire
LCLyn Chitty
Lyn Chitty
ATAndrew M. Taylor
Andrew M. Taylor
OAOwen J. Arthurs
Owen J. Arthurs
Aim of this study was to investigate whether lung assessment on post-mortem magnetic resonance imaging (PMMR) can reliably differentiate between live birth and stillbirth.

16 September 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JEJonathan C. Erickson
Jonathan C. Erickson
LBLaura E. Bruce
Laura E. Bruce
ATAndrew Taylor
Andrew Taylor
JRJohn Richman
John Richman
CHConnor Higgins
Connor Higgins
GOGreg O'Grady
Greg O'Grady
Objective: This work validates a novel non-invasive method to identify periods of cyclic motor activity in the colon using multichannel skin-surface electrical recordings on the lower abdominal region, termed electrocolonography (EColG). Methods: EColG recordings were made from 21 human subjects during a 3 hr meal-response study. A signal processing pipeline based on Continuous Wavelet Transform time-frequency analysis was used to quantify the spectral power in the colonic frequency band ( $\approx$ 2-6 cycles per minute; cpm) during the fasted and fed states. Results: EColG identified a substantial 7.4 ± 3.5 × maximum transient increase in motor activity in the fed state versus the fasted state, as well as a 38.3 ± 16.7% sustained spectral power increase in the colonic frequency band. The dominant frequency was 3.61 ± 0.49 cpm, with activity localized primarily in the infraumbilical region near the (recto-)sigmoid colon segments. Conclusion: The colonic meal-responses identified with EColG were closely concordant with rectosigmoid motor activity previously characterized by intracolonic high-resolution manometry. This study is the first to demonstrate that body surface electrical recordings can properly identify rhythmic colonic activity stimulated by food intake. Significance: The new EColG technique is inexpensive, portable, and presents the opportunity for reliably measuring colonic motility by noninvasive means. We anticipate that EColG could be applied to monitor the progression of postoperative ileus, and more precisely diagnose abnormal colonic motor patterns in patients suffering from common functional disorders, such as irritable bowel syndrome.

20 May 2012 in BMC Public Health
Verified
Journal Article
Open access
PDF file
IPIain A Pretty
Iain A Pretty
MMMichael McGrady
Michael McGrady
CZChristian Zakian
Christian Zakian
RERoger P Ellwood
Roger P Ellwood
ATAndrew Taylor
Andrew Taylor
BDBruce A Dye
Bruce A Dye
To determine if a novel dual camera imaging system employing both polarized white light (PWL) and quantitative light induced fluorescence imaging (QLF) is appropriate for measuring enamel fluorosis in an epidemiological setting. The use of remote and objective scoring systems is of importance in fluorosis assessments due to the potential risk of examiner bias using clinical methods.