Benjamin Rush Waller

Benjamin Rush Waller

Auto-generated profile, based on publicly available information

Benjamin Rush Waller

Le Bonheur Children's Hospital, United States

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2016 in Congenital Heart Disease
Verified
Journal Article
Closed access
PDF file
LHLauren Haddad
Lauren Haddad
BWB. Rush Waller
B. Rush Waller
Jason Nathaniel JohnsonJason Nathaniel Johnson
Jason Nathaniel Johnson
ACAsim Choudhri
Asim Choudhri
VMVera McGhee
Vera McGhee
SSShyam Sathanandam
Shyam Sathanandam
Background Three‐dimensional rotational angiography (3DRA) offers more detailed anatomic information than 2D digital acquisition (2DDA). Concerns over potentially higher contrast and radiation doses have limited its routine use. Objective The primary objective of this study was to compare radiation doses required to obtain 3DRA using a customized low dose radiation protocol with 2DDA. The secondary objective was to compare total procedural radiation in pediatric cardiac catheterization procedures utilizing 3DRA to those that do not. Study Design Phantom studies were conducted to establish customized 3DRA protocols for radiation reduction. Comparison of 3DRA and non‐3DRA procedures in age‐, size‐ and diagnosis‐matched controls was performed. Radiation doses were indexed to body surface area (BSA) to account for differing body habitus as validated from the phantom study. Results Study (n = 100) and control (n = 100) groups were matched for age (10.2 vs. 9.98 years; P = .239) and BSA (1.23 vs. 1.09 m2; P = .103). The dose area product (DAP) to acquire a 3DRA was similar to a 5 s, 15 frames/second 2DDA (278 vs. 241 cGy/cm2; P = .14). Despite the 3DRA group consisting of more complex interventions, no difference was found in the total procedural Air Kerma and DAP indexed to BSA (244 vs. 249 mGy/m2; P = .79 and 3348 vs. 3176 cGy/cm2/m2; P = .48, respectively). The contrast volume to acquire a 3DRA compared to a 2DDA was greater (1.59 vs. 1.01 mL/kg; P < .001). However, no difference was found for the entire procedure (3.8 vs. 4 mL/kg, P = .494). This could have resulted from the need to obtain multiple 2DDAs to achieve the detail of a single 3DRA (11 vs. 7 per study; P < .001). Conclusions When 3DRA, using the proposed protocols is employed, total procedural contrast and radiation doses are comparable with the sole use of biplane cine‐angiograms. These protocols may allow for routine use of 3DRA for congenital cardiac catheterizations.

1 November 2021 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
AKAshley M. Kiene
Ashley M. Kiene
BWB. Rush Waller
B. Rush Waller
CKChristopher Knott-Craig
Christopher Knott-Craig
SSShyam Sathanandam
Shyam Sathanandam

1 June 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
RPRanjit Philip
Ranjit Philip
NTNeil Tailor
Neil Tailor
Jason Nathaniel JohnsonJason Nathaniel Johnson
Jason Nathaniel Johnson
LALeah Apalodimas
Leah Apalodimas
JCJorden Cunningham
Jorden Cunningham
SSShyam Sathanandam
Shyam Sathanandam

21 September 2021 in Children
Verified
Journal Article
Open access
PDF file
RPRanjit Philip
Ranjit Philip
Jeffrey A. TowbinJeffrey A. Towbin
Jeffrey A. Towbin
NTNeil Tailor
Neil Tailor
VJVijaya Joshi
Vijaya Joshi
Jason Nathaniel JohnsonJason Nathaniel Johnson
Jason Nathaniel Johnson
SSShyam Sathanandam
Shyam Sathanandam
The transcatheter closure of patent ductus arteriosus (TCPC) has been demonstrated to be feasible even in infants weighing ≤1000 g. However, other percutaneous cardiac interventions (PCI) for such small infants born with congenital heart defects (CHD) or acquired heart defects (AHD) have not been well described. The purpose of this study was to describe the feasibility and safety of PCI in infants ≤1000 g. A retrospective review was conducted between June 2015 and May 2021, looking at 148 consecutive PCIs performed on infants weighing ≤1000 g at the time of the procedure. The procedural success rate was 100%. The major adverse event (AE) rate for TCPC was 3%, while there were no major AEs for other PCI. It is feasible to perform PCIs in infants weighing ≤1000 g with CHD and AHD using currently available technologies.

1 May 2017 in Congenital Heart Disease
Verified
Journal Article
Closed access
PDF file
MPMichael Perez
Michael Perez
TKTk Susheel Kumar
Tk Susheel Kumar
DHDeepthi Hoskoppal
Deepthi Hoskoppal
YAYada Akkhawattanangkul
Yada Akkhawattanangkul
KAKimberly Allen
Kimberly Allen
SSShyam Sathanandam
Shyam Sathanandam
The primary objective of this study was to demonstrate that pulmonary artery (PA) debanding via cardiac catheterization using balloon angioplasty is feasible and safe in swine. The secondary objectives were to determine the acute and long-term effects of this therapy. This is a chronic survival experimental study in newborn swine. PA bands are used in infants for transient palliation of congenital heart defects with excessive pulmonary blood flow. Although rare, if these defects should close spontaneously or become hemodynamically insignificant, a sternotomy and occasionally cardiopulmonary bypass may still be required for band removal. Alternatively, debanding could be accomplished through less invasive methods. The main pulmonary artery was banded in three piglets, and the left pulmonary artery in five piglets via mini-thoracotomy at a mean weight of 2.5 kg. Following a threefold increase in weight, the piglets underwent PA debanding via balloon angioplasty. Four piglets were sacrificed to evaluate the acute effects. The remainder were followed to evaluate long-term effects. Histopathology was performed on all piglets. Reintervention rates. Histopathologic consequences of high pressure balloon angioplasty used for PA debanding acutely and after reinterventions. Debanding was performed at a mean weight of 8.1 ± 2.23 kg. The median preintervention gradient across the band was 18 mm Hg. Debanding was successful in all piglets. The median postintervention gradient was 3.5 mm Hg. All piglets in the long-term model required re-interventions for recurrent stenosis at mean weights of 26 ± 1.6 and 61 ± 3.2 kg. Histopathology demonstrated vessel wall injury in only one piglet. Endovascular PA debanding can be safely achieved in a swine model. Angioplasty following debanding may be necessary for recurrent stenosis. This catheter-based therapy may provide a less-invasive alternative to surgery.