Background: Periodontal infections, which serve as a reservoir of inflammatory mediators, may pose a threat to the fetal-placental unit and cause adverse pregnancy outcomes.
Debonding is a common cause of failure encountered with fiber-reinforced composite (FRC) posts, and usually occurs along the post space-dentin adhesive interface. The aim of this in vitro study is to evaluate the regional push-out bond strength of a fiber-reinforced post system, using two resin cements. In this in vitro study 20 maxillary central incisors were decoronated and the roots were endodontically treated. Following post space preparation, the roots were divided into two groups of 10 specimens each. Fiber-reinforced composite posts were cemented with two resin cement systems: (a) Self-etch system (Panavia F2.0/ED-primer II) and (b) conventional system (Variolink II/Excite DSC). Three slices of each root, with a thickness of 3 mm, were prepared. The push-out test was performed with a universal testing machine at a crosshead speed of 1 mm/minute, and bond strength values were calculated. The data were analyzed with a two-way Analysis of variance (ANOVA) and Scheffe tests (α=.05). There were no significant differences between the mean push-out bond strengths of two experimental groups (Panavia F: 12.59±5.44, Variolink II: 12.49±4.52 MPa) (P=0.920), but there were significant differences between the mean push out bond strengths of the root dentin regions (P<0.001). Under the conditions of this study, there was no significant difference between the mean push out bond strength of self-etching and the conventional resin cement systems. The coronal region of the root dentin showed a significantly higher bond strength than the apical region.
Determination of maturation and evaluation of growth potential is extremely important in clinical orthodontics. The purpose of this study was to evaluate the diagnostic performance of the mandibular second molar calcification stages for identification of growth phases. In this cross-sectional descriptive study, samples were derived from panoramic radiographs and lateral cephalograms of 125 subjects (61 males and 64 females) with age ranging from 8 to 17 years and estimates of dental maturity (Demirjian Index [DI]) and skeletal maturity (Cervical vertebral maturation indicators CVMI]) were made. Correlations between DI and CVMI were shown by Spearman's correlation. The diagnostic performance of the DI for the identification of the growth phase were evaluated using positive likelihood ratios (LHRs), with a threshold of ≥10 for satisfactory performance. Correlations between second molar calcification and growth phase were 0.819 for females and 0.805 for males (P-value< 0.0001). LHR ≥10 was only observed for the identification of the post-pubertal growth phase for the H stage of the second molar. In spite of the high correlation coefficients between mandibular second molar calcification stages and skeletal maturity, these stages are reliable only for the identification of the post pubertal growth phase. Key words:Skeletal maturation, demirjian Index, mandibular second molar.
19 June 2022 in Clinical and Experimental Dental Research
Objective: Diagnostic casts are one of the standard components of orthodontic records. But they have several drawbacks such as the need for physical space for storage and the risk of breaking due to their brittle composition. Today, the digitalization of orthodontic models is a progress in orthodontics. The purpose of this study was to compare and evaluate common orthodontic linear measurements on plaster casts and digital 3D models using Maestro 3D ortho studio® scanner and software (AGE Solutions®, Pontedera, Italy).Materials and Methods: Study casts of 30 orthodontic patients were selected. Tooth width, space analysis, Bolton analysis, overjet, overbite, and linear measurements of dental arch dimensions were performed by two examiners on plaster casts and digital models.Statistical Analysis: Intra‐ and interexaminer agreements were evaluated in both manual and digital methods and pairedt test was used for evaluating the agreement between the manual and digital measurement. The significance level was set at 0.05.Results: The intraexaminer agreement was excellent (ICC > 0.75) for most variables in both manual and digital methods. The correlation between the two examiners was significant (p < .05) for most manual and digital measurements. The differences between the manual and digital measurements, although maybe statistically significant, were not clinically significant for most variables.Conclusion: The use of “Maestro 3D” (AGE Solutions, Pontedera, Italy) scanner and software was acceptable for orthodontic diagnostic measurements instead of study casts.
25 February 2023 in American Journal of Orthodontics and Dentofacial Orthopedics