1 July 2013 in Biophysical Journal
4 May 2011 in Biomedical Optics Express
Micron-sized liquid perfluorocarbon (PFC) droplets are currently being investigated as activatable agents for medical imaging and cancer therapy. After injection into the bloodstream, superheated PFC droplets can be vaporized to a gas phase for ultrasound imaging, or for cancer therapy via targeted drug delivery and vessel occlusion. Droplet vaporization has been previously demonstrated using acoustic methods. We propose using laser irradiation as a means to induce PFC droplet vaporization using a method we term optical droplet vaporization (ODV). In order to facilitate ODV of PFC droplets which have negligible absorption in the infrared spectrum, optical absorbing nanoparticles were incorporated into the droplet. In this study, micron-sized PFC droplets loaded with silica-coated lead sulfide (PbS) nanoparticles were evaluated using a 1064 nm laser and ultra-high frequency photoacoustic ultrasound (at 200 and 375 MHz). The photoacoustic response was proportional to nanoparticle loading and successful optical droplet vaporization of individual PFC droplets was confirmed using photoacoustic, acoustic, and optical measurements. A minimum laser fluence of 1.4 J/cm2 was required to vaporize the droplets. The vaporization of PFC droplets via laser irradiation can lead to the activation of PFC agents in tissues previously not accessible using standard ultrasound-based techniques.
1 December 2013 in Photoacoustics
Photoacoustic measurements of melanoma cells and red blood cells (RBCs) using ultra-high frequency (UHF) wide-bandwidth transducers are reported. In this detection system, the resolution typically depends on the parameters of the receiving transducer, and not the focus of the laser. A single melanoma cell was imaged with 200, 375 and 1200 MHz transducers. As the frequency increased, the resolution increased, resulting in greater detail observed. A single RBC was imaged at 1200 MHz, showing the contours of the cell. While lateral and axial resolutions approaching 1 μm are possible with this microscope, the key advantage is the ability to perform a wide-bandwidth quantitative signal analysis of the photoacoustic signals. The power spectrum of the signals measured from RBCs showed distinct spectral minima around 800 and 1500 MHz which are directly related to the RBC geometry. This study reports on the high-resolution imaging capabilities and quantitative analyses using UHF photoacoustic microscopy.
1 March 2016 in Photoacoustics
High resolution ultrasound and photoacoustic images of stained neutrophils, lymphocytes and monocytes from a blood smear were acquired using a combined acoustic/photoacoustic microscope. Photoacoustic images were created using a pulsed 532 nm laser that was coupled to a single mode fiber to produce output wavelengths from 532 nm to 620 nm via stimulated Raman scattering. The excitation wavelength was selected using optical filters and focused onto the sample using a 20× objective. A 1000 MHz transducer was co-aligned with the laser spot and used for ultrasound and photoacoustic images, enabling micrometer resolution with both modalities. The different cell types could be easily identified due to variations in contrast within the acoustic and photoacoustic images. This technique provides a new way of probing leukocyte structure with potential applications towards detecting cellular abnormalities and diseased cells at the single cell level.
30 September 2010 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Time-resolved acoustic microscopy was used to measure properties of cells such as the thickness, sound velocity, acoustic impedance, density, bulk modulus, and attenuation, before and after apoptosis. A total of 12 cells were measured, 5 apoptotic and 7 non-apoptotic. Measurements made at 375 MHz showed a statistically significant increase in the cell thickness from 13.6 ± 3.1 μm to 17.3 ± 1.6 μm, and in the attenuation from 1.08 ± 0.21 dB/cm/MHz to 1.74 ± 0.36 dB/cm/MHz. The other parameters, such as the sound velocity, density, acoustic impedance, and bulk modulus remained similar within experimental error. Acoustic images obtained at 1.0 GHz showed increased RF-signal backscatter and a clear delineation of the nucleus and cytoplasm from apoptotic cells compared with non-apoptotic cells. Extensive activity was observed optically and acoustically within apoptotic cells. Acoustic measurements made one minute apart showed variations in the ultrasonic backscatter but not attenuation in the cells, which indicated rapid structural changes were occurring but not changes in bulk composition. The normalized crosscorrelation coefficient was used to quantify the variations in the backscatter RF-signal during apoptosis by comparing the first RF signal measured to each successive RF signal every 10 s. A coefficient of 1 indicates strong correlation, whereas a coefficient of 0 indicates no correlation. An average correlation coefficient of 0.93 ± 0.05 was measured for non-apoptotic cells, compared with 0.68 ± 0.17 for apoptotic cells, indicating that the RF signal as a function of time varied rapidly during apoptosis.
29 September 2014 in Advanced Functional Materials