Patrick Kulaga

Patrick Kulaga

Auto-generated profile, based on publicly available information

Patrick Kulaga

Department of Biomedical Engineering, Boston University, Boston, MA, 02215-2407, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2025 in bioRxiv
Verified
Preprint
Open access
JLJacob E. Labovitz
Jacob E. Labovitz
PKPatrick Kulaga
Patrick Kulaga
EDEric M. DuBois
Eric M. DuBois
KLKunyu Li
Kunyu Li
TOTimothy M. O’SHea
Timothy M. O’SHea
Traumatic injury to the healthy central nervous system (CNS) causes mechanical tissue damage that results in localized cell death and blood-brain-barrier (BBB) disruption. CNS tissue damage stimulates a multicellular wound response to limit the extent of damage but fails to reestablish the normal function of injured tissue. There is strong interest in developing new strategies to augment regeneration after CNS injury. To enable therapy development, reliable assays to screen and identify molecular approaches to augment glial-based wound responses over fibrotic scarring are needed. Scratch assays, which involve mechanically removing cells from an in vitro culture, allow for the simulation of wounds with high throughput and tight control over applied treatments to mechanistically study cell migration and proliferation functions that are critical to effective repair. Current methods require researchers to individually scratch each well with a pipette tip, resulting in low throughput as well as inconsistent scratch widths, straightness, and efficacy within and between wells. Here, we describe the design of a quickly assembled (<30min), inexpensive (<$110) scratch assay rig that readily creates uniform scratches that are straight (average tortuosity < 1.1), have tunable widths (730-1100µm), and fully remove damaged cells from the simulated wound region. Designed for a 24-well plate, the rig allows for high-throughput screening of varied experimental conditions or for testing many replicates. Application of the scratch assay device on an in vitro culture of neural progenitor cells (NPC) demonstrates the ability to detect differences in wound closure rate for three unique media conditions. These results support the implementation of this high-throughput scratch assay rig as a method to standardize and improve the efficiency of in vitro wound healing studies.

1 September 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
EDEric M. DuBois
Eric M. DuBois
KLKunyu Li
Kunyu Li
PKPatrick Kulaga
Patrick Kulaga
LHLaboni F. Hassan
Laboni F. Hassan
HAHonour O. Adewumi
Honour O. Adewumi
TOTimothy M. O’SHea
Timothy M. O’SHea
Astrocyte border formation is a conserved neuroprotective response to neural tissue disruption, yet astrocyte border states at implanted biomaterials remain less well characterized than injury responses. Here, we developed the Astrocyte Border Characterization (ABC) Tool, which leverages a shear-thinning, injectable biomaterial to locally deliver astrocyte-specific RiboTag AAVs and small molecule regulators in the mouse striatum, enabling molecular profiling and phenotypic modulation of astrocyte border (AB) cells. Spatially precise delivery of AAV using the ABC Tool yielded enhanced specificity and robust RiboTag expression in AB cells from 7-70 days post injection. Temporal transcriptomic profiling of AB cells revealed predominantly acute, transient changes in genes governing dedifferentiation, proliferation, metabolic reprogramming, and inflammation regulation. Persistent changes accounted for only 14% of regulated genes but involved critical gain of functions in immune regulation and host defense that mirrored astrocyte border responses at chronic CNS injuries. Local delivery of indiscriminate or astrocyte-selective ablation molecules delayed, rather than prevented, border formation, ultimately yielding thicker astrocytes borders with increased inflammation and fibrosis at the biomaterial-tissue interface. Conversely, local delivery of β-hydroxybutyrate (BHB) from the ABC Tool altered key aspects of the transcriptional reprogramming to attenuate chronic astrocyte reactivity and prevent biomaterial contraction without exacerbating inflammation or fibrosis. Our findings establish the ABC Tool as a bioassay for studying and manipulating astrocyte borders at implanted biomaterials and identify focal metabolic regulation as a strategy to modulate AB cell phenotypes and enhance the CNS biocompatibility of biomaterials.