Christian Seim

Christian Seim

Auto-generated profile, based on publicly available information

Christian Seim

Technische Universität Berlin, Institut für Physik und Astronomie , Hardenbergstr. 36 Berlin 10623

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2019 in Contact Dermatitis
Verified
Journal Article
Open access
PDF file
JSJørgen Serup
Jørgen Serup
KCKatrina Hutton Carlsen
Katrina Hutton Carlsen
NDNils Dommershausen
Nils Dommershausen
MSMitra Sepehri
Mitra Sepehri
BHBernhard Hesse
Bernhard Hesse
ISInes Schreiver
Ines Schreiver
Background: Red tattoos are prone to allergic reactions. The identity of the allergen(s) is mostly unknown.Objectives: Chemical analysis of human skin biopsies from chronic allergic reactions in red tattoos to identify culprit pigment(s) and metals.Material and methods: One hundred four dermatome biopsies were analyzed by matrix‐assisted laser desorption/ionization tandem mass spectrometry (MALDI‐MS/MS) for identification of commonly used organic pigments. Metal concentrations were assessed by inductively coupled plasma (ICP)‐MS and x‐ray fluorescence (XRF). Fourteen patients had cross‐reactions in other red tattoos.Results: In total, the identified pigments were mainly azo Pigment Red (P.R.) 22 (35%), P.R. 210 (24%), P.R. 170 (12%), P.R. 5 (0.9%), P.R. 112 (0.9%), and Pigment Orange (P.O.) 13 (11%). P.R. 122 (0.9%) and Pigment Violet (P.V.) 23 (8%) were also common. P.R. 22, P.R. 170, and P.R. 210 also dominated in patients with cross‐reactions. In 22% of the biopsies, no red pigment was detected. Element analysis indicated the presence of the sensitizers nickel and chromium.Conclusions: P.R. 22, P.R. 170, and P.R. 210 were identified as the prevailing pigments behind chronic allergic reactions in red tattoos. The epitope causing the reaction might be a pigment‐degradation product. Metal contamination may derive from different sources, and its role in red tattoo allergy cannot be ascertained.

7 October 2020 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
ADAurélie Dehlinger
Aurélie Dehlinger
CSChristian Seim
Christian Seim
HSHolger Stiel
Holger Stiel
STShailey Twamley
Shailey Twamley
ALAntje Ludwig
Antje Ludwig
BKBirgit Kanngießer
Birgit Kanngießer
Laboratory transmission soft X-ray microscopy (L-TXM) has emerged as a complementary tool to synchrotron-based TXM and high-resolution biomedical 3D imaging in general in recent years. However, two major operational challenges in L-TXM still need to be addressed: a small field of view and a potentially misaligned rotation stage. As it is not possible to alter the magnification during operation, the field of view in L-TXM is usually limited to a few tens of micrometers. This complicates locating areas and objects of interest in the sample. Additionally, if the rotation axis of the sample stage cannot be adjusted prior to the experiments, an efficient workflow for tomographic imaging cannot be established, as refocusing and sample repositioning will become necessary after each recorded projection. Both these limitations have been overcome with the integration of a visible-light microscope (VLM) into the L-TXM system. Here, we describe the calibration procedure of the goniometer sample stage and the integrated VLM and present the resulting 3D imaging of a test sample. In addition, utilizing this newly integrated VLM, the extracellular matrix of cryofixed THP-1 cells (human acute monocytic leukemia cells) was visualized by L-TXM for the first time in the context of an ongoing biomedical research project.

16 June 2025 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
CSChristian Seim
Christian Seim
JGJavier Gerber
Javier Gerber
JSJussi-Petteri Suuronen
Jussi-Petteri Suuronen
EBEmely Bortel
Emely Bortel
BKBernd Küstner
Bernd Küstner
BHBernhard Hesse
Bernhard Hesse

15 July 2025 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
ADAurélie Dehlinger
Aurélie Dehlinger
VAValentina Alberini
Valentina Alberini
VUVladimir Usatikov
Vladimir Usatikov
CDCéline Dyhring
Céline Dyhring
SJSarah Jung
Sarah Jung
CSChristian Seim
Christian Seim
Method development for laboratory-based X-ray microscopes operating in the water-window range invariably involves the development of the X-ray source as well. This paper presents major upgrades to the laboratory soft X-ray microscope (L-TXM) plasma chamber and data analysis protocol. Characterization of the laser-plasma source demonstrates improved performance, while a proof-of-principle tomogram of a diatom showcases a robust data treatment protocol and the system's capabilities for three-dimensional imaging and segmentation. These developments mark significant progress toward making L-TXM a more robust and user-friendly tool for soft X-ray microscopy applications.