Skin cancer is one of the most common forms of cancer and is overrepresented around the eyes. The gold standard for the diagnosis and treatment of skin cancer is surgical excisional biopsy and hist...
4 March 2024 in Scandinavian Journal of Rheumatology
ObjectiveConventional two-dimensional ultrasound has been assessed for the non-invasive diagnosis of giant cell arteritis (GCA), but the results are operator dependent, resulting in low sensitivity. Tomographic three-dimensional (3D) ultrasound is a novel technique that enables the objective documentation of vessel geometry. Here, for the first time, its utility is assessed for visualizing temporal arteries.MethodThe temporal artery of 14 healthy subjects and three subjects with suspected GCA was examined using tomographic 3D ultrasound.ResultsThis technique enabled 3D mapping of the architecture of the temporal artery. The inner and outer vessel diameters showed considerable interindividual variability. However, calculation of the vessel wall fraction revealed the combination of vessel wall thickening and lumen narrowing, which may be indicative of GCA.ConclusionsThis proof-of-concept study indicates that tomographic 3D ultrasound can be used for objective mapping of the temporal artery. The technique must be evaluated regarding its diagnostic sensitivity in GCA before it can be introduced in clinical practice.
13 May 2022 in Scandinavian Journal of Rheumatology
Giant cell arteritis (GCA) is a treatable, but potentially sight- and life-threatening form of systemic vasculitis. Prompt and correct diagnosis is therefore important. Temporal artery biopsy (TAB)...
There is a need for a simple, non-invasive, and easily accessible 3D imaging technique for the anophthalmic socket to create imaging data for future 3D printing of prostheses. This study aimed to investigate the feasibility of using a novel handheld tomographic ultrasound for 3D mapping of the anophthalmic socket. Ten anophthalmic sockets were scanned using a tomographic ultrasound system and the results were compared to CT scanned impression molds from the same sockets. The tomographic ultrasound provided detailed 3D maps of the anophthalmic sockets. The mean difference between the ultrasound-mapped socket and the CT-scanned imprints was within clinically acceptable limits for most patients. Specifically, the minimum separation distance was less than 3 mm in most cases. In three patients, larger deviations were noted as a result of uneven socket surfaces, indicating the need for further refinement in these cases. Tomographic ultrasound shows promise for 3D imaging of the posterior surface of the anophthalmic socket and may, in the future, support 3D printing of prostheses. However, further refinement is needed to make the technique clinically applicable.