Department of Business Economics, Health & Social Care, University of Applied Sciences & Arts of Southern Switzerland, Stabile Piazzetta, Via Violino 11, 6928 Manno, Switzerland
Auto-generated profile, based on publicly available information
Emilia Riggi
Department of Business Economics, Health & Social Care, University of Applied Sciences & Arts of Southern Switzerland, Stabile Piazzetta, Via Violino 11, 6928 Manno, Switzerland
Objective To present comparative data about the performance of colorectal cancer (CRC) screening programmes in the European Union Member States (EU MSs). Design Cross-sectional study. We analysed key performance indicators—participation rate, positivity rate (PR), detection rate (DR) and positive predictive value for adenomas and CRC—based on the aggregated quantitative data collected for the second EU screening report. We derived crude and pooled (through a random effects model) estimates to describe and compare trends across different MSs/regions and screening protocols. Results Participation rate was higher in countries adopting faecal immunochemical test (FIT) (range: 22.8%–71.3%) than in those using guaiac faecal occult blood test (gFOBT) (range 4.5%–66.6%), and it showed a positive correlation (ρ=0.842, p<0.001) with participation in breast cancer screening in the same areas. Screening performance showed a large variability. Compliance with referral for colonoscopy (total colonoscopy (TC)) assessment ranged between 64% and 92%; TC completion rate ranged between 92% and 99%. PR and DR of advanced adenomas and CRC were higher in FIT, as compared with gFOBT programmes, and independent of the protocol among men, older subjects and those performing their first screening. Conclusions The variability in the results of quality indicators across population-based screening programmes highlights the importance of continuous monitoring, as well as the need to promote quality improvement efforts, as recommended in the EU guidelines. The implementation of monitoring systems, ensuring availability of data for the entire process, together with initiatives aimed to enhance reproducibility of histology and quality of endoscopy, represent a priority in screening programmes management.
Objectives: To characterize the seasonal variation, over one year, in water-quality, antibiotic residue levels, antibiotic resistance genes and antibiotic resistance in Escherichia coli isolates from water and sediment of the Kshipra River in Central India. Methods: Water and sediment samples were collected from seven selected points from the Kshipra River in the Indian city of Ujjain in the summer, rainy season, autumn and winter seasons in 2014. Water quality parameters (physical, chemical and microbiological) were analyzed using standard methods. High-performance liquid chromatography–tandem mass spectrometry was used to determine the concentrations of antibiotic residues. In river water and sediment samples, antibiotic resistance and multidrug resistance patterns of isolated E. coli to 17 antibiotics were tested and genes coding for resistance and phylogenetic groups were detected using multiplex polymerase chain reaction. One-way analysis of variance (ANOVA) and Fisher tests were applied to determine seasonal variation. Results: In river water, seasonal variation was significantly associated with various water quality parameters, presence of sulfamethoxazole residues, bacteria resistant to ampicillin, cefepime, meropenem, amikacin, gentamicin, tigecycline, multidrug resistance and CTX-M-1 gene. The majority of the Extended Spectrum Beta-Lactamase (ESBL)-producing E. coli isolates from river water and sediment in all different seasons belonged to phylogenetic group A or B1. Conclusions: Antibiotic pollution, resistance and resistance genes in the Kshipra River showed significant seasonal variation. Guidelines and regulatory standards are needed to control environmental dissemination of these “pollutants” in this holy river.
The emergence of antibiotic resistance is a major global and environmental health issue, yet the presence of antibiotic residues and resistance in the water and sediment of a river subjected to excessive anthropogenic activities and their relationship with water quality of the river are not well studied. The objectives of the present study were a) to investigate the occurrence of antibiotic residues and antibiotic-resistant Escherichia coli (E. coli) in the water and sediment of the Kshipra river in India at seven selected sites during different seasons of the years 2014, 2015, and 2016 and b) to investigate the association between antibiotic residues and antibiotic-resistant E. coli in water and sediment and measured water quality parameters of the river. Antibiotic residues and resistant E. coli were present in the water and sediment and were associated with the measured water quality parameters. Sulfamethoxazole was the most frequently detected antibiotic in water at the highest concentration of 4.66 µg/L and was positively correlated with the water quality parameters. Significant (p < 0.05) seasonal and spatial variations of antibiotic-resistant E. coli in water and sediment were found. The resistance of E. coli to antibiotics (e.g., sulfamethiazole, norfloxacin, ciprofloxacine, cefotaxime, co-trimoxazole, ceftazidime, meropenem, ampicillin, amikacin, metronidazole, tetracycline, and tigecycline) had varying associations with the measured water and sediment quality parameters. Based on the results of this study, it is suggested that regular monitoring and surveillance of water quality, including antibiotic residues and antibiotic resistance, of all rivers should be taken up as a key priority, in national and Global Action Plans as these can have implications for the buildup of antibiotic resistance.
Objective To estimate the predictive role of faecal haemoglobin (f-Hb) concentration among subjects with faecal immunochemical test (FIT) results below the positivity cut-off for the subsequent risk of advanced neoplasia (AN: colorectal cancer—CRC—or advanced adenoma). Design Prospective cohort of subjects aged 50–69 years, undergoing their first FIT between 1 January 2004 and 31 December 2010 in four population-based programmes in Italy. Methods All programmes adopted the same analytical procedure (OC Sensor, Eiken Japan), performed every 2 years, on a single sample, with the same positivity cut-off (20 µg Hb/g faeces). We assessed the AN risk at subsequent exams, the cumulative AN detection rate (DR) over the 4-year period following the second FIT and the interval CRC (IC) risk following two negative FITs by cumulative amount of f-Hb concentration over two consecutive negative FITs, using multivariable logistic regression models and the Kaplan-Meier method. Results The cumulative probability of a positive FIT result over the subsequent two rounds ranged between 7.8% (95% CI 7.5 to 8.2) for subjects with undetectable f-Hb at the initial two tests (50% of the screenees) and 48.4% (95% CI 44.0 to 53.0) among those (0.7% of the screenees) with a cumulative f-Hb concentration ≥20 µg/g faeces. The corresponding figures for cumulative DR were: 1.4% (95% CI 1.3 to 1.6) and 25.5% (95% CI 21.4 to 30.2) for AN; 0.17% (95% CI 0.12 to 0.23) and 4.5% (95% CI 2.8 to 7.1) for CRC. IC risk was also associated with cumulative f-Hb levels. Conclusion The association of cumulative f-Hb concentration with subsequent AN and IC risk may allow to design tailored strategies to optimise the utilisation of endoscopy resources: subjects with cumulative f-Hb concentration ≥20 µg/g faeces over two negative tests could be referred immediately for total colonoscopy (TC), while screening interval might be extended for those with undetectable f-Hb.
Randomized trials from the United Kingdom, Norway, and the United States found a protective effect of screening flexible sigmoidoscopy against colorectal cancer incidence and mortality over 15 to 1... Visual Long-Term Effectiveness of Flexible Sigmoidoscopy Screening. Randomized trials from the United Kingdom, Norway, and the United States found a protective effect of screening flexible... Background: Recent reports showed that the protective effect of flexible sigmoidoscopy (FS) screening was maintained up to17 years, although differences were reported by sex. Objective: To assess l...