Paweł Tchórzewski

Paweł Tchórzewski

Auto-generated profile, based on publicly available information

Paweł Tchórzewski

R&D Center Netrix S.A., Lublin, Poland

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in International Journal of Applied Electromagnetics and Mechanics
Verified
Journal Article
Closed access
PDF file
TRTomasz Rymarczyk
Tomasz Rymarczyk
PTPaweł Tchórzewski
Paweł Tchórzewski
The paper presents a solution for testing the humidity of a brick wall using electrical tomography. Different prototypes of measurement systems based on the device with hybrid tomography were prepared. Prepared constructions contain 16 electrodes in a brick wall on one side and two-sided. Electrical tomography, which is based on the measurement of potential difference, can be used to check historical buildings. The way in which we can determine the condition of a wall of moisture depends on the fact that each material has a unique conductivity. The use of modern tomographic techniques in combination with topological algorithms will allow non-destructive and non-destructive very accurate spatial assessment of the humidity level. The proposed application uses the Total Variation, Gauss–Newton and level set method to solve the inverse problem in electrical tomography.

20 August 2024 in Journal of Modern Science
Verified
Journal Article
Open access
PTPaweł Tchórzewski
Paweł Tchórzewski
MDMałgorzata Lalak - Dybała
Małgorzata Lalak - Dybała
BPBartosz Przysucha
Bartosz Przysucha
POPaweł Olszewski
Paweł Olszewski
The article presents a study of the application of electro-impedance tomography (EIT) in diagnosing lung capacity using the Tikhonov regularization method. The possibility of reconstructing the lungs to monitor the degree of air filling was investigated. The experiment included a series of tests using a torso phantom designed to simulate different states of the lungs - from fully inflated to fully deflated. Lung-filling states were manipulated in controlled scenarios to test nine main experimental conditions reflecting different lung-filling states. In addition, the quality of reconstruction was checked using various types of reference backgrounds. The results show significant differences in lung volume reconstructions depending on the lung filling state. The most successful reconstructions, which were obtained using the 'No phantom' background, provided the most explicit visualization of the lungs, reassuring the method's reliability. The experiments confirm the potential of EIT to distinguish between different lung states and reconstruct the degree of lung filling. The study also underscores the need to optimize the reference background to increase the precision of the images, especially for the left lung.

4 December 2024
Verified
Conference Paper
Open access
BSBarbara Stefaniak
Barbara Stefaniak
AKAmelia Kosior-Romanowska
Amelia Kosior-Romanowska
PTPaweł Tchórzewski
Paweł Tchórzewski
DWDariusz Wójcik
Dariusz Wójcik
TRTomasz Rymarczyk
Tomasz Rymarczyk
POPaweł Olszewski
Paweł Olszewski
The article discusses research on a wearable medical diagnostic system using electrical impedance tomography. This system aims to diagnose long-term respiratory diseases, particularly COPD, ARDS, pneumothorax, pneumonia, bron-chospasm, and pulmonary hypertension. It seeks to reduce the number of tests needed for accurate diagnoses, thus saving time. The article compares two classification models for distinguishing between diseased and healthy individuals. This approach helps streamline the diagnostic process.


20 August 2024 in Journal of Modern Science
Verified
Journal Article
Open access
GBGrzegorz Marian Bartnik
Grzegorz Marian Bartnik
MGMagdalena Głowacka
Magdalena Głowacka
MGMichał Gołąbek
Michał Gołąbek
PTPaweł Tchórzewski
Paweł Tchórzewski
This study aims to integrate ultrasound tomography with numerical algorithms to significantly enhance brain sensing capabilities for diagnosing critical brain abnormalities. Advanced ultrasound tomography, employing a high-frequency transducer array, captures intricate brain structures. The echoes processed by multi-channel receivers allow for three-dimensional imaging. Deep learning models, particularly convolutional neural networks, undergo rigorous training on extensive datasets. Hyperparameter tuning and regularization are key to model optimization. Algorithms handle large datasets, detecting subtle pathological changes in ultrasound images. The system demonstrates proficient image reconstruction and analysis. Implementing deep learning algorithms rectifies operator-dependent inconsistencies and imaging artifacts. The analysis shows significant improvements in diagnostic accuracy and processing time. The convergence of ultrasound tomography and deep learning faces challenges such as image quality variation, computational demands, and clinical integration. Despite these, the enhanced image clarity and the ability to conduct real-time analytics are promising. The study sets a new standard in neurological diagnostics, indicating the potential for sophisticated diagnostic tools to become accessible in diverse healthcare settings.